Seth and Gary arrived on time, were neat and thorough in cleaning the entire furnace assembly, including A/C coil, blower etc. Furnace was very dirty. Now sounds better and should run more efficiently. Very happy with their level of knowledge and understanding of what it took to improve furnace efficiency.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Timely and Informative

Seth was on time and efficient in identifying the issue with our furnace. Options are being identified and we will make a decision on what to do.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always use Westin!

Always great service, great price and knowledgeable service techs. Highly recommend for complete HVAC or small repair.

  • Overall Experience
  • Quality
  • Price
  • Convenience

on time, clean and professional service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great friendly service

Seth was great, and answered all my questions. We'll definitely use Westin Air again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

great job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very Professional and Efficient Service

We have great experience with Westin Air and more specific with our Technician Seth Peters who is an extremely professional and wise technician.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Preventive Service

Seth was on time, performed the service in a timely manner. Everything was cleaned up and working as required.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Ontime Service

Called the office at 9:30 AM regarding my AC not working properly. By noon Seth was there repairing it. Took him 5 minutes to determine the issue and another :30 to repair it. Thanks all - Erik

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

The entire experience was great

Great experience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for dublin, oh

Graham M.

Graham M. Job Checkin

Upon arrival inspected unit and found dirty burners clogging and not establishing flame on all 4 burners. Informed homeowner of issue and likelihood of problem reoccurring without repair measures, homeowner was interested in upgrading burners to stainless steel to prevent future problems pertaining establishing flame. Replaced 4 burners with stainless steel burners and test run furnace. Cleaned flame sensor as well while things were apart, and sealed every hole on furnace burner cabinet to prevent dust from homeowners woodworking shop in furnace room from damaging components internally. No issues as of now. Filter merv rating is higher than usual - I would recommend no higher than merv 10 but it is fully optional


Graham M.

Graham M. Job Checkin

Part# 74w59 in stock PO- SW9890glasglow Remove and replace inducer motor under manufacture warranty. Test run furnace and verify operation. Homeowner was concerned about popping noises with water heater previous visit, noticed more noises today and advised to consult a plumber due to risk of failure and being without warm water when one heater is down. Furnace is heating perfectly fine with new motor. Unit is in good shape at this time.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 210 popup - new today truck stock Clean flame sensor Ohm test igniter: Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 5.3amp Check amp draw on inducer motor:0.77amp Check delta T - 53° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 ok 8/25 Clean flame sensor Ohm test igniter: 47.6 Inspect wiring for loose connections and/or hot spots - Check humidifier pad: ok #35 Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.2 Check amp draw on inducer motor:1.2 Check delta T - 48° Furnace is in optimal running conditions

Gas heating preventative maintenance performed
Check filter - 20x25x4 ok 8/25
Clean flame sensor
Ohm test igniter: 47.6
Inspect wiring for loose connections and/or hot spots - 
Check humidifier pad: ok #35
Inspect exhaust flu - no concerns 
Set thermostat for heat
Check amp draw on blower motor: 3.2
Check amp draw on inducer motor:1.2
Check delta T -  48°
Furnace is in optimal running conditions

Brandon P.

Brandon P. Job Checkin

Upon arrival, Rick had the furnace already in heating mode to recreate specific situation where strange scent is detected. Upon opening the basment door and taking a step inside, there was a distinct scent change but it smelled more like laundry scents rather than burning plastic. Scent was vaguely detectable near furnace and water heater. Unable to pinpoint scent. While on site, used combustiin analyzer to test first floor vent, basment vent at bottom of stairs, and areas surround furnace for any Carbon Monoxide. 0PPM CO det3cted during and testing. Inspected blower motor, blower compartment, inducer motor, and combustion compartment for anything that could create a burning or strange chemical smell. No issues were found during inspections and testing. Suspect that the scent is something to do with the laundry area being near the basment steps and furnace. If it has not been done recently or checked recently, recommend having the dryer vent checked and/or cleaned to ensure dryer vent


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane high efficiency furnace. Trane Clean Effects filter cleaning. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Furnace is operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Upon arrival, inspected furnace and homeowner had me working on the wrong unit, found one with dirty filters, and the other system had a seized inducer motor. Called Lennox and ordered replacement part under manufacturer warranty, informed homeowner of a potentially blocked water heater vent due to carbon monoxide seeping from vent


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a 2022 Lennox 96% efficient single stage natural gas furnace Replaced aprilaire 35 water panel for the humidifier Tightened water line on the outlet of the solenoid to stop a small leak Pulled condensate lines and cleared debris that was causing a water backup into the inducer housing Tightened clamp on inducer outlet coupling to stop a water leak Pulled burner door off and inspected burners Removed flame sensor and cleaned 20x25x4 filter is good Blower wheel is dirty with drywall dust from new construction Recommend cleaning the blower wheel Run tested furnace Adjusted gas pressure to 3.0"wc. and increased blower speed to high Temperature rise 67⁰ (spec is 45-75⁰) Humidifier working properly, no water leaks at this time Other than the dirty blower wheel, furnace is in good shape and operating properly at this time. Signed up for gold maintenance plan


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20xx25x1 washable filter new today Clean flame sensor Ohm test igniter: 65.3 Burners rusty and needed cleaned. New today with stainless steel Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today #35 owner supply Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.38 Check amp draw on inducer motor:0.91 Check delta T - 62° Furnace is in optimal running conditions


Brandon P.

Brandon P. Job Checkin

Goodman high efficiency furnaces running in good condition. 16x25x1 air filter is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on 2024 Daikin high efficiency furnace. AA210 filter is new. Checked condition of humidifier steam canister in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 3" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane high efficiency furnace. 20x25x4 air filter is in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Humidifier damper is open, pad in good condition. Test run system in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Tested in heating modes. Took down all measurments. Will need to sonsukt with office and Waterfurnace tech support. Replaced fp1 sensor covered under part and labor warranty. Test ran operation and monitored fp1 readings.


Nate G.

Nate G. Job Checkin

Diagnosed failed thermostat Replaced thermostat Tested system operation Furnace operating normally at this time.


Graham M.

Graham M. Job Checkin

Upon arrival, inspected furnace and found no major concerns. Discussed with homeowner and requested for more information from previous visit. Photos shown to me resembled the burner compartment and the pinch welds of the factory heat exchanger. Nothing concerning was seen. Homeowner was still interested in further inspection and requested a combustion analysis be performed. Performed combustion analysis and found no concerns with combustion process, unit is only making 24 ppm COAF and 12 ppm CO on high fire. Unit is of great health for age being 22 years old. Recommend no changes unit is of good health.

Upon arrival, inspected furnace and found no major concerns. Discussed with homeowner and requested for more information from previous visit. Photos shown to me resembled the burner compartment and the pinch welds of the factory heat exchanger. Nothing concerning was seen. Homeowner was still interested in further inspection and requested a combustion analysis be performed. Performed combustion analysis and found no concerns with combustion process, unit is only making 24 ppm COAF and 12 ppm CO on high fire. Unit is of great health for age being 22 years old. Recommend no changes unit is of good health. Upon arrival, inspected furnace and found no major concerns. Discussed with homeowner and requested for more information from previous visit. Photos shown to me resembled the burner compartment and the pinch welds of the factory heat exchanger. Nothing concerning was seen. Homeowner was still interested in further inspection and requested a combustion analysis be performed. Performed combustion analysis and found no concerns with combustion process, unit is only making 24 ppm COAF and 12 ppm CO on high fire. Unit is of great health for age being 22 years old. Recommend no changes unit is of good health.