725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for dublin, oh

Rated 4.7 out of 5 stars based on 13 customer reviews

Wrong person

We Aren't your customer

  • Overall Experience
  • Quality
  • Price
  • Convenience

Westin Air Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Homeowner

Seth and Gary arrived on time, were neat and thorough in cleaning the entire furnace assembly, including A/C coil, blower etc. Furnace was very dirty. Now sounds better and should run more efficiently. Very happy with their level of knowledge and understanding of what it took to improve furnace efficiency.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Timely and Informative

Seth was on time and efficient in identifying the issue with our furnace. Options are being identified and we will make a decision on what to do.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always use Westin!

Always great service, great price and knowledgeable service techs. Highly recommend for complete HVAC or small repair.

  • Overall Experience
  • Quality
  • Price
  • Convenience

on time, clean and professional service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great friendly service

Seth was great, and answered all my questions. We'll definitely use Westin Air again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

great job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very Professional and Efficient Service

We have great experience with Westin Air and more specific with our Technician Seth Peters who is an extremely professional and wise technician.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Preventive Service

Seth was on time, performed the service in a timely manner. Everything was cleaned up and working as required.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Ontime Service

Called the office at 9:30 AM regarding my AC not working properly. By noon Seth was there repairing it. Took him 5 minutes to determine the issue and another :30 to repair it. Thanks all - Erik

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

The entire experience was great

Great experience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for dublin, oh

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x5 new today gold Clean flame sensor Inspect burners - no concerns Ohm test igniter: 54.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: clean Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.92 Check amp draw on inducer motor:1.01 Check delta T - 58° Furnace is in optimal running conditions Gas heating preventative maintenance performed Check filter - 16x25x4 new today gold Clean flame sensor Inspect burners - no concerns Ohm test igniter: 63.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: clean Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 2.31 Check amp draw on inducer motor:0.92 Check delta T - 53° Furnace is in optimal running conditions Homeowner stated concerns with 2nd floor unit not seeming to satisfy demand. Did not find any errors with


Jason D.

Jason D. Job Checkin

SOLD: 01/05/2026 12:31:50 PM - Option 2 Install New Bryant HVAC System Bryant Preferred 2-Stage Gas Furnace Model #: 927TA48080V17 Serial #:502558575 80,000 BTU's - 97% AFUE Bryant Single-Stage Air Conditioner Model #: GA5SAN53000W Serial #: 4825X88284 2.5 Ton - 14.3 SEER2 Puron Advance Refrigerant, R-454B Matching Cased Coil: CVAVA3017XMA Serial #: 2525J82728 Installation: * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system *Air Filtration - AprilAire 1210 (20X25) Media Air Cleaner Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)


SOLD: 01/05/2026 12:31:50 PM - Option 2

Install New Bryant HVAC System 
Bryant Preferred 2-Stage Gas Furnace
Model #: 927TA48080V17
Serial #:502558575
80,000 BTU's - 97% AFUE
Bryant Single-Stage Air Conditioner
Model #: GA5SAN53000W
Serial #: 4825X88284
2.5 Ton - 14.3 SEER2
Puron Advance Refrigerant, R-454B
Matching Cased Coil: CVAVA3017XMA
Serial #: 2525J82728
 
Installation:
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
*Air Filtration - AprilAire 1210 (20X25) Media Air Cleaner
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

SOLD: 01/05/2026 12:31:50 PM - Option 2

Install New Bryant HVAC System 
Bryant Preferred 2-Stage Gas Furnace
Model #: 927TA48080V17
Serial #:502558575
80,000 BTU's - 97% AFUE
Bryant Single-Stage Air Conditioner
Model #: GA5SAN53000W
Serial #: 4825X88284
2.5 Ton - 14.3 SEER2
Puron Advance Refrigerant, R-454B
Matching Cased Coil: CVAVA3017XMA
Serial #: 2525J82728
 
Installation:
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
*Air Filtration - AprilAire 1210 (20X25) Media Air Cleaner
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

Graham M.

Graham M. Job Checkin

Upon arrival inspected Ssysyem and found broken inducer cooling wheel. Inform homeowner of noise source and recommend repair with spare wheel from office. Repair was approved obtained wheel and repaired inducer then test ran furnace and performed heating PMI. Gas heating preventative maintenance performed Check filter - clean Clean flame sensor Inspect burners : no concerns Ohm test igniter: 64.3 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.21 Check amp draw on inducer motor:0.92 Check delta T - 54° Furnace is in optimal running conditions

Upon arrival inspected Ssysyem and found broken inducer cooling wheel. Inform homeowner of noise source and recommend repair with spare wheel from office. Repair was approved obtained wheel and repaired inducer then test ran furnace and performed heating PMI. 
Gas heating preventative maintenance performed
Check filter - clean
Clean flame sensor
Inspect burners : no concerns 
Ohm test igniter: 64.3
Inspect wiring for loose connections and/or hot spots - none found
Check humidifier pad: n/a
Inspect exhaust flu - no concerns
Set thermostat for heat
Check amp draw on blower motor: 4.21
Check amp draw on inducer motor:0.92
Check delta T -  54°
Furnace is in optimal running conditions Upon arrival inspected Ssysyem and found broken inducer cooling wheel. Inform homeowner of noise source and recommend repair with spare wheel from office. Repair was approved obtained wheel and repaired inducer then test ran furnace and performed heating PMI. 
Gas heating preventative maintenance performed
Check filter - clean
Clean flame sensor
Inspect burners : no concerns 
Ohm test igniter: 64.3
Inspect wiring for loose connections and/or hot spots - none found
Check humidifier pad: n/a
Inspect exhaust flu - no concerns
Set thermostat for heat
Check amp draw on blower motor: 4.21
Check amp draw on inducer motor:0.92
Check delta T -  54°
Furnace is in optimal running conditions

Nate G.

Nate G. Job Checkin

Performed heating maintenance ona Daikin 2 stage 96% furnace Replaced aprilaire 210 filter Replaced aprilaire #35 humidifier water panel Humidifier is no longer leaking water Discussed arzel zone panel operation Advised closing some basement vents to push more air to the basement bedroom Cleaned furnace flame sensor Blower in OK condition Burners are spotless Condensate trap is clear No water leaks inside or outside the furnace No stored fault codes for the system System in great shape at this time


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on high efficiency Carrier furnace running in great condition. Air filter in good condition. #35 humidifier pad in good condition. Clean flame sensor and check ignitor ohms. Visual inspection of burners. Flush condensation trap and drain lines. Humidifier controller is not working. Rewired and programmed thermostat for humidifier control. Test run operation of heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane furnace. 16x25x1 air filter in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Test ran system in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Jason D.

Jason D. Job Checkin

Construction Warranty Diag on Ticking in walls


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 16x25x1 clean Clean flame sensor Inspect burners - no concerns Ohm test igniter: 47.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a no room for accessories Inspect exhaust flu - no concerns pvc Set thermostat for heat Check amp draw on blower motor: 3.90 Check amp draw on inducer motor:0.35 Check delta T - 54° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed basement Check filter - 210 new today platinum Clean flame sensor Inspect burners - no concerns clean Ohm test igniter: 46.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today owner supply Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 1.2 Check amp draw on inducer motor:0.23 Check delta T - 54° Furnace is in optimal running conditions Gas heating preventative maintenance performed 1st floor Check filter - 210 new today Clean flame sensor Inspect burners - no concerns Ohm test igniter: 51.1 Inspect wiring for loose connections and/or hot spots -none found Check humidifier pad: Inspect exhaust flu - Set thermostat for heat Check amp draw on blower motor: 1.6 Check amp draw on inducer motor:0.14 Check delta T - 48° Furnace is in optimal running conditions Gas heating preventative maintenance performed 2nd floor Check filter - 210 new today C


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x1 clean Clean flame sensor Inspect burners - rusty replaced with stainless steel Ohm test igniter: 56.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: #10 in a #35 case -off for leaking safety Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.42 Check amp draw on inducer motor:0.84 Check delta T - 66° Furnace is in optimal running conditions


Brandon P.

Brandon P. Job Checkin

Plugged gas orifice on burner with igniter. used thermostat wire to unplug. No more ignition issues during multiple test runs.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - Trane Clean Effects clean by homeowner. Clean flame sensor Inspect burners - no concerns. Ohm test igniter: 49.8 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: clean Inspect exhaust flu - no concerns. Set thermostat for heat Check amp draw on blower motor: 10.9 Check amp draw on inducer motor:0.55 Check delta T - 52° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Replace all two inch plated filters homeowner supply Service 2 of the 5 Aprilaire 700m humidifiers replacing panels on bad ones set humidity to 40% on basement systems. Plugin aurora and check for faults on all 5 systems. Monitor each system while running verifying no concerns during max performance Run test all auxiliary emergency heat circuits verifying operation No concerns at this time all units are working


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on three Trane high efficiency gas furnaces running in great condition. All three air filters replaced today. Replaced humidifier pad on main system humidifier. Calcium clogged humidifier pad was causing water leak. Cleaned flame sensors and checked ignitors. Visual inspection of burners. Flush condensation traps and drain lines. Run test each system in heating mode from thermostat. All systems are operating within specifications for temperature rise, blower Amp draw, inducer Amp draw, and gas pressures. Pvc flue vents are in good condition and no sign of leaks. 0PPM CO detected during testing. Run test humidifier to ensure no leaks. All systems are operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on three Bryan furnace systems all running properly. Basement systems air filters in clean condition. Replaced attic system filter while up there. Basement systems humidifiers in working order with clean condition water panels. For all furnaces, cleaned flame sensor and check ignitor. Visual inspection of burners. For basement systems, flushed through condensation trap and drain lines. Run test each system in heating mode from respective thermostat. Each system is operating with parameters for temperature rise, blower Amp draw, inducer Amp draw, and blower capacitor readings. Humidifiers tested during heating tests. No issues found with furnace systems. Nick mentioned that the two bedrooms upstairs were colder than the master bedroom where the thermostat is. He already keeps the doors open. Recommended turning the fan on for the system to constantly circulate air. Also mentioned that the remote sensors could be used in those rooms and possibly tell