725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for dublin, oh

Rated 4.7 out of 5 stars based on 13 customer reviews

Wrong person

We Aren't your customer

  • Overall Experience
  • Quality
  • Price
  • Convenience

Westin Air Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Homeowner

Seth and Gary arrived on time, were neat and thorough in cleaning the entire furnace assembly, including A/C coil, blower etc. Furnace was very dirty. Now sounds better and should run more efficiently. Very happy with their level of knowledge and understanding of what it took to improve furnace efficiency.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Timely and Informative

Seth was on time and efficient in identifying the issue with our furnace. Options are being identified and we will make a decision on what to do.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always use Westin!

Always great service, great price and knowledgeable service techs. Highly recommend for complete HVAC or small repair.

  • Overall Experience
  • Quality
  • Price
  • Convenience

on time, clean and professional service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great friendly service

Seth was great, and answered all my questions. We'll definitely use Westin Air again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

great job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very Professional and Efficient Service

We have great experience with Westin Air and more specific with our Technician Seth Peters who is an extremely professional and wise technician.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Preventive Service

Seth was on time, performed the service in a timely manner. Everything was cleaned up and working as required.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Ontime Service

Called the office at 9:30 AM regarding my AC not working properly. By noon Seth was there repairing it. Took him 5 minutes to determine the issue and another :30 to repair it. Thanks all - Erik

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

The entire experience was great

Great experience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for dublin, oh

seth p.

seth p. Job Checkin

Install OEM replacement Maxcore service port on compressor discharge line, adjust to OEM book specs with new R410A System is running in very good condition at this time


Nate G.

Nate G. Job Checkin

Billable to Corinthian. GFCI outside that the condensing unit is plugged into was tripped again. Explained to Kevin and the homeowner that the Receptacle needs switched out to a non-gfci style. Refrigerant charge is correct.


Graham M.

Graham M. Job Checkin

Perform cooling PMI 45+5 cap full Wash coil clogged with dust Check refrigerant pressures. 10° subcool 23° delta T Call was originally for no cool - discovered loose thermostat connection on control board tightened connections and everything is back operational.


seth p.

seth p. Job Checkin

One system Trane 3 ton R410A single stage air conditioning cooling system tune up, maintenance, cleaning, safety inspection. Air filter is like new on schedule with homeowners, 20x25x1 pleated Filtrete Shut down Honeywell humidifier airflow damper, controller, and water stop valve. Water flush AC coil drain, Minor adjustments to IFC cooling blower speed setup. Turn off heat pump mode and reduce cooling blower tap from 7 to 6 Wi-Fi vision pro 8000 2415, functioning in good condition, turn on auto changeover mode, turn off adaptive intelligence mode Run test outdoor equipment in cooling mode, water flush condenser coils, inspect electronics, record refrigerant pressures running at 123/15 superheat & 286/15 subcool

One system Trane 3 ton R410A single stage air conditioning cooling system tune up, maintenance, cleaning, safety inspection.
Air filter is like new on schedule with homeowners, 20x25x1 pleated Filtrete
Shut down Honeywell humidifier airflow damper, controller, and water stop valve. Water flush AC coil drain, 
Minor adjustments to IFC cooling blower speed setup. Turn off heat pump mode and reduce cooling blower tap from 7 to 6
Wi-Fi vision pro 8000 2415, functioning in good condition, turn on auto changeover mode, turn off adaptive intelligence mode 
Run test outdoor equipment in cooling mode, water flush condenser coils, inspect electronics, record refrigerant pressures running at 123/15 superheat & 286/15 subcool

seth p.

seth p. Job Checkin

Five system geothermal cooling season Four system package equipment full system cooling equipment tune up, maintenance, safety inspection, drain flush, run testing, filter inspections, thermostat battery replacement, shut down all steam humidifiers One system detached garage equipment minor maintenance and visual run test in heating and cooling All air filters are in good condition and none needed replaced today *Master bedroom humidifier had service code for water fill valve, main great room / kitchen system had service code for high amp draw on canister. *The last remaining synergy 3D system servicing the great room & kitchen area has a oil leak on the high pressure discharge line Max core service port. The system is running good today however the oil leak will need addressed ASAP. Seth will prepare estimate and discuss with John


seth p.

seth p. Job Checkin

To system gas furnace air conditioning cooling season preventive maintenance inspection, tune up, cleaning, safety inspection Replace both air filters included with gold plan. Basement system - RP2200 Honeywell pop up space guard replacement, adding system Honeywell 20x25x4 pleated disposable media, basement system plenum and drain are sealed and not serviceable. Shut down both humidifiers downstairs and perform minor maintenance cleaning on both systems. Inspect and clean attic system evap drain pan and drain line Test run both outdoor condensers in cooling mode. Second floor replacement system is running in excellent condition with all electronics and refrigerant pressures within specs. Basement system is 25 years old this season with a 2000 serial number and r22 refrigerant. Ac equipment is running in fair to good condition although under today's conditions the refrigerant pressures are registering lower than normal but most likely due to no heat load indoors with 64 return air a


Nate G.

Nate G. Job Checkin

Performed cooling maintenance Blower is clean Indoor coil clean Adjusted positioning of TXV tubing to prevent rubbing from mechanical vibration Changed filter Closed humidifier bypass damper Outdoor coil is clean Capacitor 36.5/7.5 rated 40/7.5 +/-10% Replaced spade terminal for the start wire on the Compressor to the capacitor terminal Installed turbo 200 capacitor


Brandon P.

Brandon P. Job Checkin

2007 Rheem R-22 AC running in good condition despite age. 20x25x4 air filter is new on 4-1. Unable to inspect indoor coil due to door not being removable without cutting drain line and exhaust vent. Flushed coil drain pan through safety switch. Test ran in cooling mode from thermostat. Delta t of 18F with supply temp of 50F. R-22 refrigerant pressures are within spec for low outdoor temperature. High 110psi with 14F SC, low 50psi with 13F SH. Outdoor coils are in clean condition. Recommend checking again when Bradford Pear trees have dropped their flowers. Dual run capacitor, compressor, and fan motor are all operating within spec. No issues found on today's visit. System is operational and ready for Summer.

2007 Rheem R-22 AC running in good condition despite age. 20x25x4 air filter is new on 4-1. Unable to inspect indoor coil due to door not being removable without cutting drain line and exhaust vent. Flushed coil drain pan through safety switch. Test ran in cooling mode from thermostat. Delta t of 18F with supply temp of 50F. R-22 refrigerant pressures are within spec for low outdoor temperature. High 110psi with 14F SC, low 50psi with 13F SH. Outdoor coils are in clean condition. Recommend checking again when Bradford Pear trees have dropped their flowers. Dual run capacitor, compressor, and fan motor are all operating within spec. No issues found on today's visit. System is operational and ready for Summer.

Brandon P.

Brandon P. Job Checkin

Seven system cooling maintenance inspection Upon arrival the home does not have any well pump pressure. Service codes on both well pump drivers. Homeowner is aware of the issues and the well pump company is in route Check all thermostats and batteries, inspect all filters, flush all the condensate drains, adjust all return air vents for summer operation Investigate well pump operation, and discharge wells with the well pump service man No equipment has been test run or recharged with any refrigerant for cooling system service More than likely multiple systems will need power cycled to reset any lockouts due to no water flow Office space water furnace in The mechanical room in the garage needs a replacement Square D red flag 30 amp two pole supply voltage breaker.


seth p.

seth p. Job Checkin

Equipment warranty After performing a leak search with electronic detection and ultraviolet dye and not finding anything in the way of refrigerant, oil, or dye, deeper investigations were performed with maximum limits performance testing resulting in everizing discharge pressures exceeding 420 PSI with 45° water pressure. Suction pressure is stuck at 96 PSI and will only drop when refrigerant is recovered to lower the discharge head pressure. In conclusion the split geothermal heating thermostatic expansion valve and liquid line refrigerant dryer needs replaced with all new R410A puran refrigerant Office staff will order warranty parts online and follow up with homeowners for scheduling. Estimated 4 to 6 hours on site WaterFurnace NDZ038J100CNN0BA 231000892


Nate G.

Nate G. Job Checkin

Replace condenser fan motor, blade, and dual capacitor. Too cold to fully test the system. Furnace is installed incorrectly. The bottom plate is removed, so the blower is pulling in unfiltered air from the basement, which is nothing but dryer lint. Blower is plugged, AC evaporator coil will likely have freeze up issues.


Nate G.

Nate G. Job Checkin

Diagnostic warranty call from 2-27-2025 no charge Low fire gas pressure was falling too low and shutting the furnace down. Trane really doesn't the gas control adjusted, but in their service manual for this Furnace it does have the gas pressure adjustment procedure and gas pressure specifications. Before adjustment, the gas pressure was falling below 0.8" and specification is 0.9" with an allowable 0.2" increase. Set low fire gas pressure to 1.1". Cycled furnace numerous times. Operating normally at this time.


Brandon P.

Brandon P. Job Checkin

Unable to diagnose cause of error. System will intermittently show pressure switch codes with occasional flame loss. Main issue noticed is that thr inducer motor after fireoff will slow down to a point where the pressure switch opens and system will shut off. While inducer motor is at a higher speed during and just after fireoff, pressure switch is satisfied. Attempted to run with burner box door off, attempted to run with the exhaust pulled off. Nothing tested would change to operation of the furnace. System would run for 1-2 minutes before the inducer motor slowed down so much the pressure switch would open. Furnace would only intermittently show codes and control system on furnace would not allow me to lock it into high fire. Due to erattic behavior, suspect it may be the control board, but cannot be certain. We will need to send someone else out to inspect.


Graham M.

Graham M. Job Checkin

Remove and replace PS1 pressure switch attempting to resolve no heat issue from this morning. Furnace showing PS1 open and PS1 closed errors switch seems to be sticking and not returning as desired Quote# 25619630. Pickup at Trane WEST Upon arrival unit was in an error loop for PS1 kept attempting to start and switch would close then release as if motor was not staying on but motor continues running fine. Replaced pressure switch and unit instantly sensed the switch working properly closing and holding and fired up. Test ran unit and no more issues after new switch


Graham M.

Graham M. Job Checkin

Upon arrival inspected unit and found no major concerns. Went through fault history and found two errors for PS1 reading stuck shut and stuck open. Switch is showing evidence of sticking and causing unit to intermittently be inoperable. Quote replacement PS1 switch advising Bruce no hard evidence of part failure but from saved errors this seems to be his issue and should hopefully resolve it.