725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for dublin, oh

Rated 4.7 out of 5 stars based on 13 customer reviews

Wrong person

We Aren't your customer

  • Overall Experience
  • Quality
  • Price
  • Convenience

Westin Air Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Homeowner

Seth and Gary arrived on time, were neat and thorough in cleaning the entire furnace assembly, including A/C coil, blower etc. Furnace was very dirty. Now sounds better and should run more efficiently. Very happy with their level of knowledge and understanding of what it took to improve furnace efficiency.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Timely and Informative

Seth was on time and efficient in identifying the issue with our furnace. Options are being identified and we will make a decision on what to do.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always use Westin!

Always great service, great price and knowledgeable service techs. Highly recommend for complete HVAC or small repair.

  • Overall Experience
  • Quality
  • Price
  • Convenience

on time, clean and professional service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great friendly service

Seth was great, and answered all my questions. We'll definitely use Westin Air again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

great job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very Professional and Efficient Service

We have great experience with Westin Air and more specific with our Technician Seth Peters who is an extremely professional and wise technician.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Preventive Service

Seth was on time, performed the service in a timely manner. Everything was cleaned up and working as required.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Ontime Service

Called the office at 9:30 AM regarding my AC not working properly. By noon Seth was there repairing it. Took him 5 minutes to determine the issue and another :30 to repair it. Thanks all - Erik

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

The entire experience was great

Great experience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for dublin, oh

Brandon P.

Brandon P. Job Checkin

Goodman high efficiency furnaces running in good condition. 16x25x1 air filter is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on 2024 Daikin high efficiency furnace. AA210 filter is new. Checked condition of humidifier steam canister in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 3" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane high efficiency furnace. 20x25x4 air filter is in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Humidifier damper is open, pad in good condition. Test run system in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Tested in heating modes. Took down all measurments. Will need to sonsukt with office and Waterfurnace tech support. Replaced fp1 sensor covered under part and labor warranty. Test ran operation and monitored fp1 readings.


Nate G.

Nate G. Job Checkin

Diagnosed failed thermostat Replaced thermostat Tested system operation Furnace operating normally at this time.


Graham M.

Graham M. Job Checkin

Upon arrival, inspected furnace and found no major concerns. Discussed with homeowner and requested for more information from previous visit. Photos shown to me resembled the burner compartment and the pinch welds of the factory heat exchanger. Nothing concerning was seen. Homeowner was still interested in further inspection and requested a combustion analysis be performed. Performed combustion analysis and found no concerns with combustion process, unit is only making 24 ppm COAF and 12 ppm CO on high fire. Unit is of great health for age being 22 years old. Recommend no changes unit is of good health.

Upon arrival, inspected furnace and found no major concerns. Discussed with homeowner and requested for more information from previous visit. Photos shown to me resembled the burner compartment and the pinch welds of the factory heat exchanger. Nothing concerning was seen. Homeowner was still interested in further inspection and requested a combustion analysis be performed. Performed combustion analysis and found no concerns with combustion process, unit is only making 24 ppm COAF and 12 ppm CO on high fire. Unit is of great health for age being 22 years old. Recommend no changes unit is of good health. Upon arrival, inspected furnace and found no major concerns. Discussed with homeowner and requested for more information from previous visit. Photos shown to me resembled the burner compartment and the pinch welds of the factory heat exchanger. Nothing concerning was seen. Homeowner was still interested in further inspection and requested a combustion analysis be performed. Performed combustion analysis and found no concerns with combustion process, unit is only making 24 ppm COAF and 12 ppm CO on high fire. Unit is of great health for age being 22 years old. Recommend no changes unit is of good health.

Brandon P.

Brandon P. Job Checkin

Replace damaged inducer motor with new oem inducer motor covered under parts warranty but no labor warranty.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on four geothermal systems. All filters are in clean condition. Test ran operation of all units in electric heating and geothermal heating modes. Tested blower motors. During electric heating, tested operation of heating strips. During operation of geothermal heating, tested ground loop temperature and pressures. Did not check any refrigerant pressures as there are no issues suspected. All systems are operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Internal seal of inducer motor has come apart and siezed the inducer motor. Inducer motor needs replaced. Part is under warranty but labor is not.

Internal seal of inducer motor has come apart and siezed the inducer motor. Inducer motor needs replaced. Part is under warranty but labor is not.

Brandon P.

Brandon P. Job Checkin

2024 Daikin high efficiency gas furnace running in new condition. Aprilaire 210 air filter is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Humidifier damper is open, pad is in good condition, and humidity is set to 40%. Test ran furnace in gas heating mode from thermostat. System is operating properly within temperature rise specifications. Manifold gas pressures are set properly. Blower motor and inducer motor are operating within specifications. 2" pvc flue vents are in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Replacement crew accidentally ran “w to furn” wire to “twin” terminal instead of W reconfigured wiring so it will properly operate heat

Replacement crew accidentally ran “w to furn” wire to “twin” terminal instead of W reconfigured wiring so it will properly operate heat

Graham M.

Graham M. Job Checkin

Perform heating PMI Check filter - 20x25x4 new 9/25 Clean flame sensor Water flush drain trap Ohm test igniter: 68.3 Burners clean stainless steel installed last year Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 5.3 Check amp draw on inducer motor:0.9 Check delta T - 64° Furnace is in optimal running conditions Customer concerns with water from drain. Seems to be either backing up from the floor or leaking from the drain line. Will have to quote drain repairs and return. Photos submitted to file

Perform heating PMI 
Check filter - 20x25x4 new 9/25 
Clean flame sensor
Water flush drain trap
Ohm test igniter: 68.3
Burners clean stainless steel installed last year
Inspect wiring for loose connections and/or hot spots - none found
Check humidifier pad: new today
Inspect exhaust flu - no concerns 
Set thermostat for heat
Check amp draw on blower motor: 5.3
Check amp draw on inducer motor:0.9
Check delta T -  64°
Furnace is in optimal running conditions

Customer concerns with water from drain. Seems to be either backing up from the floor or leaking from the drain line. Will have to quote drain repairs and return. Photos submitted to file Perform heating PMI 
Check filter - 20x25x4 new 9/25 
Clean flame sensor
Water flush drain trap
Ohm test igniter: 68.3
Burners clean stainless steel installed last year
Inspect wiring for loose connections and/or hot spots - none found
Check humidifier pad: new today
Inspect exhaust flu - no concerns 
Set thermostat for heat
Check amp draw on blower motor: 5.3
Check amp draw on inducer motor:0.9
Check delta T -  64°
Furnace is in optimal running conditions

Customer concerns with water from drain. Seems to be either backing up from the floor or leaking from the drain line. Will have to quote drain repairs and return. Photos submitted to file

Graham M.

Graham M. Job Checkin

Remove condenser motor on mini split and install factory replacement, test run system and verify no remaining issues. Unit properly operating after repairs. No further concerns on barn. Only remaining concerns on job are with the main house ac units settling below and gravel and needing raised or else coils are susceptible to rust/corrosion


Graham M.

Graham M. Job Checkin

Upon arrival inspected 3 units for barn. Started off with mini splits verifying operation, main north split will not cool or heat sufficiently. Unit outdoor fan will not run. Daikin tech support approved warranty motor for system. Clear clogged drain on 2nd floor system after discovering damp safety pan. Clear large debris from coil pan. No errors while inspecting upstairs unit with D checker nor while inspecting south wing minisplit. North wing needs ECM condenser motor replaced.


Nate G.

Nate G. Job Checkin

Performed heating maintenance Cleaned electronic air cleaner Checked humidifier, water panel looks new, tested operation... no water leaks at this time Pulled flame sensor and cleaned Pulled and cleaned burners Condensate trap clear Run tested furnace, checked gas pressure while running a combustion test High fire gas pressure 3.4" Temp rise 56, combustion test results great Low fire gas pressure 0.9" Temp rise 63, combustion test great Tested supply duct air for carbon monoxide: 0ppm detecged Furnace is operating within factory specifications

Performed heating maintenance 
Cleaned electronic air cleaner
Checked humidifier, water panel looks new, tested operation... no water leaks at this time 
Pulled flame sensor and cleaned
Pulled and cleaned burners
Condensate trap clear
Run tested furnace, checked gas pressure while running a combustion test
High fire gas pressure 3.4" Temp rise 56, combustion test results great
Low fire gas pressure 0.9" Temp rise 63, combustion test great
Tested supply duct air for carbon monoxide: 0ppm detecged 
Furnace is operating within factory specifications Performed heating maintenance 
Cleaned electronic air cleaner
Checked humidifier, water panel looks new, tested operation... no water leaks at this time 
Pulled flame sensor and cleaned
Pulled and cleaned burners
Condensate trap clear
Run tested furnace, checked gas pressure while running a combustion test
High fire gas pressure 3.4" Temp rise 56, combustion test results great
Low fire gas pressure 0.9" Temp rise 63, combustion test great
Tested supply duct air for carbon monoxide: 0ppm detecged 
Furnace is operating within factory specifications