Seth and Gary arrived on time, were neat and thorough in cleaning the entire furnace assembly, including A/C coil, blower etc. Furnace was very dirty. Now sounds better and should run more efficiently. Very happy with their level of knowledge and understanding of what it took to improve furnace efficiency.
Overall Experience
Quality
Price
Convenience
Seth was on time and efficient in identifying the issue with our furnace. Options are being identified and we will make a decision on what to do.
Overall Experience
Quality
Price
Convenience
Always great service, great price and knowledgeable service techs. Highly recommend for complete HVAC or small repair.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Seth was great, and answered all my questions. We'll definitely use Westin Air again!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
We have great experience with Westin Air and more specific with our Technician Seth Peters who is an extremely professional and wise technician.
Overall Experience
Quality
Price
Convenience
Seth was on time, performed the service in a timely manner. Everything was cleaned up and working as required.
Overall Experience
Quality
Price
Convenience
Called the office at 9:30 AM regarding my AC not working properly. By noon Seth was there repairing it. Took him 5 minutes to determine the issue and another :30 to repair it. Thanks all - Erik
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Replacement crew accidentally ran “w to furn” wire to “twin” terminal instead of W reconfigured wiring so it will properly operate heat
Perform heating PMI Check filter - 20x25x4 new 9/25 Clean flame sensor Water flush drain trap Ohm test igniter: 68.3 Burners clean stainless steel installed last year Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 5.3 Check amp draw on inducer motor:0.9 Check delta T - 64° Furnace is in optimal running conditions Customer concerns with water from drain. Seems to be either backing up from the floor or leaking from the drain line. Will have to quote drain repairs and return. Photos submitted to file
Remove condenser motor on mini split and install factory replacement, test run system and verify no remaining issues. Unit properly operating after repairs. No further concerns on barn. Only remaining concerns on job are with the main house ac units settling below and gravel and needing raised or else coils are susceptible to rust/corrosion
Upon arrival inspected 3 units for barn. Started off with mini splits verifying operation, main north split will not cool or heat sufficiently. Unit outdoor fan will not run. Daikin tech support approved warranty motor for system. Clear clogged drain on 2nd floor system after discovering damp safety pan. Clear large debris from coil pan. No errors while inspecting upstairs unit with D checker nor while inspecting south wing minisplit. North wing needs ECM condenser motor replaced.
Performed heating maintenance Cleaned electronic air cleaner Checked humidifier, water panel looks new, tested operation... no water leaks at this time Pulled flame sensor and cleaned Pulled and cleaned burners Condensate trap clear Run tested furnace, checked gas pressure while running a combustion test High fire gas pressure 3.4" Temp rise 56, combustion test results great Low fire gas pressure 0.9" Temp rise 63, combustion test great Tested supply duct air for carbon monoxide: 0ppm detecged Furnace is operating within factory specifications
2016 Trane high efficiency furnace running in great condition. 20x25x1 air filter is new today. Three more air dilters are left in the box. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Delta t of 49F with supply temp of 118F, Delta t spec of 35-65F. Humidifier pad in good condition. Damper opened and humidifier test ran during heating test. All systems are operating properly, efficiently and ready for Winter
Performed heating maintenance on a two stage trane furnace Pulled and cleaned flame sensor Pulled and cleaned burners - they were rusty Blew out Condensate trap Aprilaire 210 filter is still good Aprilaire #35 water panel is need of replacement Sold a truck stock water panel Tested humidifier while run testing furnace Operating properly and no water leaks at this time Other than the rusty burners, no concerns found with the furnace today We will clean the burners on fall visits and decide when the right time to switch to stainless burners is.
Performed two system heating maintenance Attic furnace 2018 tempstar 80% two stage natural gas furnace Pulled flame sensor and cleaned with steel wool Replaced 20x25x4 filter Blower is clean Checked inducer pressure switch port for blockage Run tested furnace High fire gas pressure set to 3.2" Low fire gas pressure set to 1.4" Inducer motor amps in spec No concerns found for attic system Basement furnace American standard 90% efficient single stage natural gas furnace Pulled and cleaned flame sensor with steel wool Pulled condensate trap and flushed with water Replaced popup 2200 filter Blower in OK condition Replaced aprilaire #80 steam cannister and verified correct operation Replaced aprilaire #35 water panel and verified correct operation Gas pressure adjustment screw cap is stuck, so setting cannot be adjusted. Furnace is over 20 years old and it is showing Replacement will be needed soon
Signs of water leakage from inducer housing. If left long enough, it potentially can damage the control board from water.
Perform heating maintenance on 3 systems Clean flame sensors Ohm test igniters verify all within spec - no concerns Filters clean house manager says they change them every 3 months Test iwave function on basement systems South basement dehumidifier at 50% and humidifier panel ok air open for both north and south humidifiers. Units on south end A/C units are sloping toward the house and buried in rocks. They would like a quote to level / potentially lift ac units above stone, photos in file.
Carrier high efficiency gas heat preventive maintenance inspection, tune up, minor maintenance cleaning, safety inspection Install replacement Honeywell 20x25x4 pleated media filter from Westin air service stock Install replacement #35 water panel and test run April 800 powered humidifier Resurface flame sensor and inspect hot surface igniter Run test all heating safety circuits Rent test multi-stage gas heating Geothermal computer scan, no active or historical fault codes present since TXV valve replacement All equipment is clean safe and ready for winter
Performed platinum heating maintenance Pulled blower housing and disassembled Cleaned blower wheel with water and brushes to remove drywall dust (Roughly 1 hour of labor) Pulled and cleaned flame sensor Pulled and cleaned burners with wire brush Pulled and flushed condensate trap Vacuumed out inside of furnace Vacuumed out wire connectors going into the blower cabinet (air gets pulled through those connectors and draws dirt into the connector pins) Run tested furnace in high and low fire Furnace is operating normally at this time, but did find signs of the inducer beginning to leak water.
Two system Trane high efficiency S9V2 heating season preventive maintenance inspection, tune up, minor maintenance cleaning, safety inspection, performance evaluation, Service and setup 2 aprilaire 600 humidifiers Full Shop-Vac cleaning of Trane clean effects air purifiers Service and replace incoming air filter on 1 HRV Inspect all accessible gas lines for leakage Flush all drain line systems All equipment is clean safe and ready for winter
Relace OEM compressor under manufacturers parts warranty. Recover and reuse all refrigerant. Running refrigerant pressures were verified at the diagnostic trip call one week ago and confirmed after all repairs No one usual noises hurt at this time system is running in excellent condition The new replacement compressor will carry the remainder of the original warranty supplied with the equipment at the original install date. *Homeowner will complete invoicing payments via online link
This equipment cannot be repaired The TXV in the York air handler has failed in the closed position restricting all refrigerant flow above 40 PSI. During testing by adding 40 oz of R422B the suction pressure rose from 37 to 41 while the liquid line pressure increased from 220 to 385 All added refrigerant has been recovered out of the system to the previous running pressures Return nest thermostat to the original temperature setting on cooling mode ****Recommend not running the system to prevent any water damage due to freeze over of the indoor coil or high pressure refrigerant loss**** Fan mode on the thermostat can be used to help circulate conditioned air from the rest of the house