725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for dublin, oh

Rated 4.7 out of 5 stars based on 13 customer reviews

Wrong person

We Aren't your customer

  • Overall Experience
  • Quality
  • Price
  • Convenience

Westin Air Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Homeowner

Seth and Gary arrived on time, were neat and thorough in cleaning the entire furnace assembly, including A/C coil, blower etc. Furnace was very dirty. Now sounds better and should run more efficiently. Very happy with their level of knowledge and understanding of what it took to improve furnace efficiency.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Timely and Informative

Seth was on time and efficient in identifying the issue with our furnace. Options are being identified and we will make a decision on what to do.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always use Westin!

Always great service, great price and knowledgeable service techs. Highly recommend for complete HVAC or small repair.

  • Overall Experience
  • Quality
  • Price
  • Convenience

on time, clean and professional service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great friendly service

Seth was great, and answered all my questions. We'll definitely use Westin Air again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

great job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very Professional and Efficient Service

We have great experience with Westin Air and more specific with our Technician Seth Peters who is an extremely professional and wise technician.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Preventive Service

Seth was on time, performed the service in a timely manner. Everything was cleaned up and working as required.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Ontime Service

Called the office at 9:30 AM regarding my AC not working properly. By noon Seth was there repairing it. Took him 5 minutes to determine the issue and another :30 to repair it. Thanks all - Erik

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

The entire experience was great

Great experience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for dublin, oh

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed basement Check filter - 210 new today platinum Clean flame sensor Inspect burners - no concerns clean Ohm test igniter: 46.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today owner supply Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 1.2 Check amp draw on inducer motor:0.23 Check delta T - 54° Furnace is in optimal running conditions Gas heating preventative maintenance performed 1st floor Check filter - 210 new today Clean flame sensor Inspect burners - no concerns Ohm test igniter: 51.1 Inspect wiring for loose connections and/or hot spots -none found Check humidifier pad: Inspect exhaust flu - Set thermostat for heat Check amp draw on blower motor: 1.6 Check amp draw on inducer motor:0.14 Check delta T - 48° Furnace is in optimal running conditions Gas heating preventative maintenance performed 2nd floor Check filter - 210 new today C


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x1 clean Clean flame sensor Inspect burners - rusty replaced with stainless steel Ohm test igniter: 56.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: #10 in a #35 case -off for leaking safety Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.42 Check amp draw on inducer motor:0.84 Check delta T - 66° Furnace is in optimal running conditions


Brandon P.

Brandon P. Job Checkin

Plugged gas orifice on burner with igniter. used thermostat wire to unplug. No more ignition issues during multiple test runs.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - Trane Clean Effects clean by homeowner. Clean flame sensor Inspect burners - no concerns. Ohm test igniter: 49.8 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: clean Inspect exhaust flu - no concerns. Set thermostat for heat Check amp draw on blower motor: 10.9 Check amp draw on inducer motor:0.55 Check delta T - 52° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Replace all two inch plated filters homeowner supply Service 2 of the 5 Aprilaire 700m humidifiers replacing panels on bad ones set humidity to 40% on basement systems. Plugin aurora and check for faults on all 5 systems. Monitor each system while running verifying no concerns during max performance Run test all auxiliary emergency heat circuits verifying operation No concerns at this time all units are working


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on three Trane high efficiency gas furnaces running in great condition. All three air filters replaced today. Replaced humidifier pad on main system humidifier. Calcium clogged humidifier pad was causing water leak. Cleaned flame sensors and checked ignitors. Visual inspection of burners. Flush condensation traps and drain lines. Run test each system in heating mode from thermostat. All systems are operating within specifications for temperature rise, blower Amp draw, inducer Amp draw, and gas pressures. Pvc flue vents are in good condition and no sign of leaks. 0PPM CO detected during testing. Run test humidifier to ensure no leaks. All systems are operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on three Bryan furnace systems all running properly. Basement systems air filters in clean condition. Replaced attic system filter while up there. Basement systems humidifiers in working order with clean condition water panels. For all furnaces, cleaned flame sensor and check ignitor. Visual inspection of burners. For basement systems, flushed through condensation trap and drain lines. Run test each system in heating mode from respective thermostat. Each system is operating with parameters for temperature rise, blower Amp draw, inducer Amp draw, and blower capacitor readings. Humidifiers tested during heating tests. No issues found with furnace systems. Nick mentioned that the two bedrooms upstairs were colder than the master bedroom where the thermostat is. He already keeps the doors open. Recommended turning the fan on for the system to constantly circulate air. Also mentioned that the remote sensors could be used in those rooms and possibly tell


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 October Clean flame sensor Inspect burners - minor rust no major concerns Ohm test igniter: 54.8 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: #10 clean, humidifier control dead no set point display and unit will not test cycle humidifier Inspect exhaust flu - 2” pvc no concerns Set thermostat for heat Check amp draw on blower motor: 3.32 Check amp draw on inducer motor:0.26 Check delta T - 45° Furnace is in optimal running conditions


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Daikin high efficiency gas furnace running in great condition. 20x25x4 air filter in new condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Humidifier pad is in poor condition due to calcium buildup and should be changed as soon as possible to prevent water leaks. Humidifier riquires an Aprilaire #35 humidifier pad. Tested operation of humidifier to verify operation. Test ran furnace in gas heating. System is operating within temperature rise specifications for both high and low stages. Blower and inducer motors tested good. 3" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane furnace running in great condition. RP2200 filter is in new condition. Clean flame sensor and check ignitor. Visual inspection of burners. Humidifier pad in good condition. Damper opened. Test run during heating test. Test ran furnace in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition. 0PPM CO detected during. System is operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane high efficiency furnace running in great condition. 20x25x1 air filter is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. Kerry mentions she was told last maintenence about something being rusty. There is nothing list3d in previous notes and there is nothing suspicious or evident issues with rust. Only suspicion could be with the intake pipe having condensation coming through but there is already an intake drain trap installed properly. No actions should be taken at this time.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane high efficiency furnace running in great condition. 20x25x4 air filter is new today. #35 humidifier pad in new condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Temperature rise is within specs for both stages. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Humidifier tested during heat test. Adjusted dampers for master bedroom and bath, aswell ad front bedroom to direct more airflow to kitchen and living room area. Will need to test for a few weeks and possibly make more changes as you see fit. Furnace is operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 new today owner supply Clean flame sensor Inspect burners - dirty. Replace with stainless steel. Ohm test igniter: 56.8 Inspect wiring for loose connections and/or hot spots - none found. Check humidifier pad: #35 new today owner supply. Inspect exhaust flu - 2”pvc no concerns. Set thermostat for heat Check amp draw on blower motor: 3.2 Check amp draw on inducer motor:1.8 Check delta T - 48° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Upon arrival, inspected system and found unit was struggling to exhaust heat from furnace heat exchanger. Unit had multiple high limit trips. Causing it to go into soft lockout. Upon discussing with Harry his 1 inch filters were only two weeks old, but there is an excessive amount of dust in the air quickly blocking filter filters. Informed Harry of potential humidifier, causing excessive dust. Recommend running filtered water in humidifiers. And changing filters once a month until problem subsides but 16x25x1 filters are good for 1-3 months max typically. On these systems he may get 2 months max being high demand.


Graham M.

Graham M. Job Checkin

Reconfigure 1 1/2” and 3/4” drain line to all 3/4”. Saving space on drain and replacing old leaking pipe. Cap off intake and remove intake drain for old water heater power vent. Make much more space in basement drain for furnace. Reroute furnace and water heater drain all drains flowing properly and no leaks at this time. Only had one 3” pvc cap so we will return Tuesday 10-2 for 3” exhaust vent cap outside will need 5” cut of 3” pvc Add additional pvc cap on exhaust pipe now blocking both pipes to the furnace room that were wide open allowing heavy moisture intake during seasons.