Excellent service, repairman came quickly and took care of my problem quickly. very happy with price and everything!
Seth was great. He was very thorough in performing an annual service for our furnace and AC units.
Seth did an excellent job. He is always easy to work with. I'm glad Westin did the furnace replacement. A great company to work with.
Geothermal replacement. A couple of issues but Westin corrected them all. We used Westin to later replace a humidifier and plan to use them for an HVAC system in a condo we own.
Love , all the staff, and Seth is really great , he cares about the customers, I can tell it’s not an act
Seth was very professional and courteous. He took the time to explain the new system with me and answered all my questions. He was on time and did quality work.
Seth is a great guy to have on your team. Doesn't mind if watch and ask questions.
Fit us in the schedule in a few days and fixed our AC at a reasonable price
Westin Air has been very helpful. They are always on time and courteous. I would recommend them if you need your furnace repaired.
North side RTU frozen up Found a leaking CoreMax service port Shut compressor down to thaw out evaporator coil Adjusted blower speed to high Added 5lbs of R410a refrigerant Both units are in immediate need of evap and Condenser coil cleanings as well as a filter change. Need to replace core max port We will get quote out ASAP
Performed cooling maintenance on a 16 seer trane ac Modified thermostat schedule to customer-requested presets. Filter is new Drain is clear Blower is OK 16⁰ delta T 10⁰ subcool Capacitor tested in spec Washed Condenser coil System in good shape and operating within factory specs at this time.
2020 Trane heatpump running in great condition. Aprilaire 416 air filter in decent condition. Check again in 1-2 months. Visual inspection of indoor coil. Flush drain pan and drain lines. Run test unit in cooling mode from thermostat. Delta t of 21F with supply temp of 51F. Refrigerant pressure are within spec. High 280psi with 11F SC, low 115psi with 10F SH. Water flushed outdoor coils to remove dirt and debris. Outdoor fan motor and compressor are operating within specs. System is operating properly, efficiently and ready for Summer.
Replace 1-in rubber hoses on open loop system between enclosed flow center and Geo package system 2 x 5' hose & armaflex insulation
Cooling preventative maintenance performed Check filter -wash clean effects Check coil for any buildup debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD - 45+5 43.8+4.87 Verify pressures and HP-SC/LP-SH 297-9°/120-10° Delta T - 19° The Air handler and AC are in optimal running conditions. Cooling preventative maintenance performed Check filter - wash clean effects Check coil for any buildup debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD - 38.70+4.75 Verify pressures and HP-SC/LP-SH 280-13°/120-20° Delta T - 21° The Air handler and AC are in optimal running conditions.
OEM water furnace 600 PSI high pressure safety switch retro kit SKHPE600
Performed cooling maintenance on a 2002 Lennox AC system Furnace actively leaking water inside the cabinet Attempted to stop the leaks with tightening hose clamps Put Condensate treatment down the drain line Filter is OK Left a filter that is provided with gold level maintenance plan Outdoor unit is partially buried in dirt and Mulch Tore down and washed unit R22 refrigerant level is reading low per the charging charts inside the unit Considering age, condition, and low charge, we recommend replacement of the furnace and AC sooner than later. Customer wants quotes for replacement
Service warranty Scan ABC computer for service codes and found 56 e10 compressor monitor service codes. Diagnostic logs do not appear to be reset after the last repair service. Clear all service code counters Homeowner indicates that Sunday night the temperature did not drop or turn on all night when lowered in the evening. ABC LED one continued to register service code 10 but could not be validated as the most recent no cooling condition. Test run equipment in low and high stage cooling modes from vision pro 8000 and aid tool Confirm multi-stage cooling operation and supply temperature at 51.6 Test replacement power supply capacitor confirm 40 UF Test thermostat operation and control wiring Could not duplicate any no cool conditions with at least four cooling cycles while on site today Ground loops were at 0 and are now repressurized to 60 psi using house water pressure
Waterfurnace had 55 occurances of E10 fault "compressor monitoring" Capacitor rated 40m measured 29 Replaced capacitor System operating normally at this time
2023 Daikin 2025 cooling silver maintenance Install replacement aprilaire 210 filter provided by homeowners, plus drain system, run test cooling mode from the Daikin one plus control, scan thermostat for diagnostic trouble codes. Homeowner is concerned about a caution triangle active after power outages. No trouble codes logged at this time Water flush condenser coil and run test outdoor unit in cooling mode. Mine are maintenance cleaning of outdoor unit and electronics inspection Close down air and controls for bypass humidifier All equipment is running an excellent condition and ready for summer Minor Air balance in the accessible side of the basement and discuss options with homeowner
Replace faulty blower motor with new universal ecm motor and program retrofit ecm motor controller. Test run operwtion in fan only and cooling speed. System is operating properly at this time.
Burst rubber hose on open loop discharge line between Geo package and enclosed flow center containing Taco zone valve Cut off one foot section of burst rubber hose and reattach to original swivel kit barb fitting. Run test equipment in cooling mode from all three zone thermostats AID tool data cable between ABC board and outside cabinet penetration has water damage and should be replaced. Recommend replacing both rubber hose kits including new armaflex insulation 2 x 5' 1" Seth will prepare estimate and contact homeowners
2009 carrier Northwest system SN: 2309E19141 Replace condenser fan motor and power supply with OEM parts required due to size limitations 440 55+5
Failed blower will not operate and allowed the indoor coil to freeze due to no airflow. Parts nor labor are cover3d under warranty. Universal ecm motor will be picked up on Monday and Ashlea will call to schedule when we have the motor.
Upon arrival found furnace blower wheel came loose and was making awful noises. Motor shaft and wheel hub damaged both need replaced under warranty. Replaced motor and wheel with oem wheel replacement and universal 3/4 hp blower.