725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for galena, oh

Rated 4.9 out of 5 stars based on 17 customer reviews

Great service!

Excellent service, repairman came quickly and took care of my problem quickly. very happy with price and everything!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Seth was great. He was very thorough in performing an annual service for our furnace and AC units.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Couldn’t do without Seth

  • Overall Experience
  • Quality
  • Price
  • Convenience

Annual Maintenance

Seth did an excellent job. He is always easy to work with. I'm glad Westin did the furnace replacement. A great company to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

arrived late

  • Overall Experience
  • Quality
  • Price
  • Convenience

Made everything right

Geothermal replacement. A couple of issues but Westin corrected them all. We used Westin to later replace a humidifier and plan to use them for an HVAC system in a condo we own.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Love , all the staff, and Seth is really great , he cares about the customers, I can tell it’s not an act

  • Overall Experience
  • Quality
  • Price
  • Convenience

Seth was very professional and courteous.

Seth was very professional and courteous. He took the time to explain the new system with me and answered all my questions. He was on time and did quality work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great tech

Seth is a great guy to have on your team. Doesn't mind if watch and ask questions.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Happy customer!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great work

Perfect

  • Overall Experience
  • Quality
  • Price
  • Convenience

Would choose them again

Fit us in the schedule in a few days and fixed our AC at a reasonable price

  • Overall Experience
  • Quality
  • Price
  • Convenience

great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Westin Air has been very helpful. They are always on time and courteous. I would recommend them if you need your furnace repaired.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for galena, oh

Nate G.

Nate G. Job Checkin

5 year labor warranty Water to water geo locking out on FP1 Dipswitch was set to 30⁰ Switched to 15⁰ Monitored FP1 temperature, went no colder than 27⁰ with both geo systems operating at the same


Jason D.

Jason D. Job Checkin

01/23/2026 9:51:37 AM - Option 1 Install New Bryant Single (2) Stage Gas Furnace Model #: 927TA48080V17 Serial #: 80,000 BTU’s - 97% AFUE Installation: * Additional Services - New PVC furnace vents. Level 2 * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system * 1" Standard Filter Rack Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)


01/23/2026 9:51:37 AM - Option 1

Install New Bryant Single (2) Stage Gas Furnace
Model #: 927TA48080V17
Serial #: 
80,000 BTU’s - 97% AFUE
 
Installation:
* Additional Services - New PVC furnace vents. Level 2 
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* 1" Standard Filter Rack
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

01/23/2026 9:51:37 AM - Option 1

Install New Bryant Single (2) Stage Gas Furnace
Model #: 927TA48080V17
Serial #: 
80,000 BTU’s - 97% AFUE
 
Installation:
* Additional Services - New PVC furnace vents. Level 2 
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* 1" Standard Filter Rack
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

Graham M.

Graham M. Job Checkin

Upon arrival inspected system and found in limit fault. Inspected filter and filter was clean dated 12/3/25 humidifier bypass open unit producing 78° rise. Unsure of cause of shift in temperature rise. Adjust gas pressure down to 3.2 and adjust blower speeds to allow 10% more airflow during heat. check temp rise now doing 65°. Unit only went into limit fault from extending runtime with extended demand from lots of in and out traffic. Gas pressure being 3.6 temp rise being high with clean filter remove diag fee


Graham M.

Graham M. Job Checkin

Upon arrival inspected system and found unit in lockout E2. Inspected pressure on refrigerant system and unit at 197 psi on high side, sensor reading OL will not close. Jumped wires until we can return with a new pressure switch. Unit will still have over amperage protection until then.

Upon arrival inspected system and found unit in lockout E2. Inspected pressure on refrigerant system and unit at 197 psi on high side, sensor reading OL will not close. Jumped wires until we can return with a new pressure switch. Unit will still have over amperage protection until then. Upon arrival inspected system and found unit in lockout E2. Inspected pressure on refrigerant system and unit at 197 psi on high side, sensor reading OL will not close. Jumped wires until we can return with a new pressure switch. Unit will still have over amperage protection until then.

Graham M.

Graham M. Job Checkin

Found no concerns with geo unit has no errors currently. Thermostat set to run furnace after 20° and below Ron requested it be at 30° below fp1 downstairs set to 15° pump reservoir full and pumping unit is working with no concerns at this time.


Jason D.

Jason D. Job Checkin

replacement warranty


Nate G.

Nate G. Job Checkin

Replace Waterfurnace FP1 sensor Install aftermarket High pressure switch and service tee Also fixed thermostat wire splice that wasn't allowing Y2 to energize at the geo


Replace Waterfurnace FP1 sensor 
Install aftermarket High pressure switch and service tee

Also fixed thermostat wire splice that wasn't allowing Y2 to energize at the geo 
Replace Waterfurnace FP1 sensor 
Install aftermarket High pressure switch and service tee

Also fixed thermostat wire splice that wasn't allowing Y2 to energize at the geo

Nate G.

Nate G. Job Checkin

Performed heating maintenance on a 2015 Trane 2 stage 96% efficient furnace running on propane Replaced filters Checked humidifier... it is not installed properly and as a result has nearly zero airflow through it. Shut it down completely (at humidistat and water valve) Humidifier will waste water and produce negligible humidification performance Furnace blower is clean Wiring in good shape Removed burner box cover Inspected burners Removed flame sensor and clesned Reinstalled flame sensor and burner cover Run tested furnace in high and low fire Ignition is reliable across the burners Gas pressures are correct Temperature rise is within mmanufacturer's specification range Inspected exhaust piping, no signs of leaks Condensate lines show no signs of leaks No water leaks inside the furnace No concerns found on today's visit

Performed heating maintenance on a 2015 Trane 2 stage 96% efficient furnace running on propane
Replaced filters
Checked humidifier... it is not installed properly and as a result has nearly zero airflow through it.  Shut it down completely (at humidistat and water valve)
Humidifier will waste water and produce negligible humidification performance 
Furnace blower is clean
Wiring in good shape
Removed burner box cover
Inspected burners 
Removed flame sensor and clesned 
Reinstalled flame sensor and burner cover
Run tested furnace in high and low fire 
Ignition is reliable across the burners
Gas pressures are correct
Temperature rise is within mmanufacturer's specification range
Inspected exhaust piping, no signs of leaks
Condensate lines show no signs of leaks
No water leaks inside the furnace
No concerns found on today's visit

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 clean Clean flame sensor Inspect burners - clean Ohm test igniter: 59 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.42 Check amp draw on inducer motor:0.49 Check delta T - 53 Furnace is in optimal running conditions


Nate G.

Nate G. Job Checkin

Florida heat pump brand geothermal heat pump 3psi refrigerant pressure Pumped up system with nitrogen Leak is in a section of the air coil that cannot be repaired Left nitrogen in the system and disconnected compressor wire harnesses to prevent it from running We will try to locate parts for a repair We will also quote a new geothermal system

Florida heat pump brand geothermal heat pump
3psi refrigerant pressure
Pumped up system with nitrogen
Leak is in a section of the air coil that cannot be repaired
Left nitrogen in the system and disconnected compressor wire harnesses to prevent it from running

We will try to locate parts for a repair
We will also quote a new geothermal system Florida heat pump brand geothermal heat pump
3psi refrigerant pressure
Pumped up system with nitrogen
Leak is in a section of the air coil that cannot be repaired
Left nitrogen in the system and disconnected compressor wire harnesses to prevent it from running

We will try to locate parts for a repair
We will also quote a new geothermal system

Nate G.

Nate G. Job Checkin

Geothermal had 155 occurrences of FP1 fault Last lockout was FP1 With aurora aid tool, monitored fp1 During start up, it went down to -11 and came back up in a short enough period of time to not trigger the fault Checked wiring of fp1, no issues found Used temperature clamp on TXV outlet to compare to fp1 numbers, fp1 was fluctuating a lot while the actual temperature of the line remained steady. Also found high pressure switch Bypassed Verified it is stuck open We will send a quote to replace fp1 sensor and install a service port tee with a high pressure switch

Geothermal had 155 occurrences of FP1 fault
Last lockout was FP1
With aurora aid tool, monitored fp1 
During start up, it went down to -11 and came back up in a short enough period of time to not trigger the fault
Checked wiring of fp1, no issues found
Used temperature clamp on TXV outlet to compare to fp1 numbers, fp1 was fluctuating a lot while the actual temperature of the line remained steady.
Also found high pressure switch Bypassed 
Verified it is stuck open

We will send a quote to replace fp1 sensor and install a service port tee with a high pressure switch

Graham M.

Graham M. Job Checkin

Remove 4” vent pipe and replace with new pipe due to rust and rot causing vent to separate and leak exhaust gases into basement. Temporarily taped for safety reasons


Graham M.

Graham M. Job Checkin

Unit is satisfying demand and not throwing any codes.

Unit is satisfying demand and not throwing any codes. Unit is satisfying demand and not throwing any codes.

Nate G.

Nate G. Job Checkin

Diagnosed failed gas valve 24V present at MV terminal, valve clicks but no gas flows

Diagnosed failed gas valve
24V present at MV terminal, valve clicks but no gas flows Diagnosed failed gas valve
24V present at MV terminal, valve clicks but no gas flows

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Waterfurnace 5 Series geothermal unit. Air filter is in decent condition. Check again in 1-2 months. Visual inspection of air coil. Check fault history with Aurora aid tool. No error fault codes in the system. Reset normal operation codes. Test run operation of electric heat strips. All strips are operating properly. Test ran in geothermal heating aswell. Bo issues found or suspected with electric strip heat, and geothermal heating. Humidifier pad is in good condition. All systems are operating properly, efficiently and ready for Winter.