725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for galena, oh

Rated 4.9 out of 5 stars based on 17 customer reviews

Great service!

Excellent service, repairman came quickly and took care of my problem quickly. very happy with price and everything!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Seth was great. He was very thorough in performing an annual service for our furnace and AC units.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Couldn’t do without Seth

  • Overall Experience
  • Quality
  • Price
  • Convenience

Annual Maintenance

Seth did an excellent job. He is always easy to work with. I'm glad Westin did the furnace replacement. A great company to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

arrived late

  • Overall Experience
  • Quality
  • Price
  • Convenience

Made everything right

Geothermal replacement. A couple of issues but Westin corrected them all. We used Westin to later replace a humidifier and plan to use them for an HVAC system in a condo we own.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Love , all the staff, and Seth is really great , he cares about the customers, I can tell it’s not an act

  • Overall Experience
  • Quality
  • Price
  • Convenience

Seth was very professional and courteous.

Seth was very professional and courteous. He took the time to explain the new system with me and answered all my questions. He was on time and did quality work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great tech

Seth is a great guy to have on your team. Doesn't mind if watch and ask questions.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Happy customer!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great work

Perfect

  • Overall Experience
  • Quality
  • Price
  • Convenience

Would choose them again

Fit us in the schedule in a few days and fixed our AC at a reasonable price

  • Overall Experience
  • Quality
  • Price
  • Convenience

great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Westin Air has been very helpful. They are always on time and courteous. I would recommend them if you need your furnace repaired.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for galena, oh

Nate G.

Nate G. Job Checkin

Geothermal had 155 occurrences of FP1 fault Last lockout was FP1 With aurora aid tool, monitored fp1 During start up, it went down to -11 and came back up in a short enough period of time to not trigger the fault Checked wiring of fp1, no issues found Used temperature clamp on TXV outlet to compare to fp1 numbers, fp1 was fluctuating a lot while the actual temperature of the line remained steady. Also found high pressure switch Bypassed Verified it is stuck open We will send a quote to replace fp1 sensor and install a service port tee with a high pressure switch

Geothermal had 155 occurrences of FP1 fault
Last lockout was FP1
With aurora aid tool, monitored fp1 
During start up, it went down to -11 and came back up in a short enough period of time to not trigger the fault
Checked wiring of fp1, no issues found
Used temperature clamp on TXV outlet to compare to fp1 numbers, fp1 was fluctuating a lot while the actual temperature of the line remained steady.
Also found high pressure switch Bypassed 
Verified it is stuck open

We will send a quote to replace fp1 sensor and install a service port tee with a high pressure switch

Graham M.

Graham M. Job Checkin

Remove 4” vent pipe and replace with new pipe due to rust and rot causing vent to separate and leak exhaust gases into basement. Temporarily taped for safety reasons


Graham M.

Graham M. Job Checkin

Unit is satisfying demand and not throwing any codes.

Unit is satisfying demand and not throwing any codes. Unit is satisfying demand and not throwing any codes.

Nate G.

Nate G. Job Checkin

Diagnosed failed gas valve 24V present at MV terminal, valve clicks but no gas flows

Diagnosed failed gas valve
24V present at MV terminal, valve clicks but no gas flows Diagnosed failed gas valve
24V present at MV terminal, valve clicks but no gas flows

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Waterfurnace 5 Series geothermal unit. Air filter is in decent condition. Check again in 1-2 months. Visual inspection of air coil. Check fault history with Aurora aid tool. No error fault codes in the system. Reset normal operation codes. Test run operation of electric heat strips. All strips are operating properly. Test ran in geothermal heating aswell. Bo issues found or suspected with electric strip heat, and geothermal heating. Humidifier pad is in good condition. All systems are operating properly, efficiently and ready for Winter.


Nate G.

Nate G. Job Checkin

Set both indoor units to 68⁰ heating with automatic fan speed Both heads are heating very nicely They are hiding the remotes to eliminate the possibility of someone changing settings without their knowledge Please pay this invoice via the link online


Brandon P.

Brandon P. Job Checkin

Install new 2-pump non-pressurized flow center Our technician has identified that the current geothermal loop field currently has an active leak (or multiple leaks) resulting in ongoing loss of loop fluid/pressure. The exact location, cause, and full extent of the leak(s) are unknown without further invasive testing or excavation, which is outside the scope of this service call. Purpose of This Repair The replacement of the flow center (and any associated valves, pumps, or flush/fill components) is being performed solely as a temporary measure intended to slow or reduce the rate of fluid loss from the existing leaking loop. This work is being done to allow continued temporary use of the geothermal system while a permanent repair or loop replacement is planned.


Install new 2-pump non-pressurized flow center

Our technician has identified that the current geothermal loop field currently has an active leak (or multiple leaks) resulting in ongoing loss of loop fluid/pressure. The exact location, cause, and full extent of the leak(s) are unknown without further invasive testing or excavation, which is outside the scope of this service call.
Purpose of This Repair
The replacement of the flow center (and any associated valves, pumps, or flush/fill components) is being performed solely as a temporary measure intended to slow or reduce the rate of fluid loss from the existing leaking loop. This work is being done to allow continued temporary use of the geothermal system while a permanent repair or loop replacement is planned. 
Install new 2-pump non-pressurized flow center

Our technician has identified that the current geothermal loop field currently has an active leak (or multiple leaks) resulting in ongoing loss of loop fluid/pressure. The exact location, cause, and full extent of the leak(s) are unknown without further invasive testing or excavation, which is outside the scope of this service call.
Purpose of This Repair
The replacement of the flow center (and any associated valves, pumps, or flush/fill components) is being performed solely as a temporary measure intended to slow or reduce the rate of fluid loss from the existing leaking loop. This work is being done to allow continued temporary use of the geothermal system while a permanent repair or loop replacement is planned.

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on 2023 Daikin gas furnace. AA210 filter in decent condition. Check again in 1-2 months. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. #35 humidifier pad in good condition. Enabled outdoor temperature humidification limit to prevent condensation on windows. Test run furnace in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Humidifier operation tested. All systems are operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Upon arrival inspected system and found unit in ignition failure code 4. Flame sensor was filthy igniter tested at 120ohms standard M style igniter. Test run unit with clean flame sensor and had no issues. Found vent pipe had multiple splits in pipe allowing exhaust gases to leak. Repaired with tape to keep system safe while temporarily operating and quote repair to vent pipe three 5 foot sections of 4” pipe and 3 90° 4” standard 1 90° 4” double

Upon arrival inspected system and found unit in ignition failure code 4. Flame sensor was filthy igniter tested at 120ohms standard M style igniter. Test run unit with clean flame sensor and had no issues. Found vent pipe had multiple splits in pipe allowing exhaust gases to leak. Repaired with tape to keep system safe while temporarily operating and quote repair to vent pipe three 5 foot sections of 4” pipe and 3 90° 4” standard 1 90° 4” double Upon arrival inspected system and found unit in ignition failure code 4. Flame sensor was filthy igniter tested at 120ohms standard M style igniter. Test run unit with clean flame sensor and had no issues. Found vent pipe had multiple splits in pipe allowing exhaust gases to leak. Repaired with tape to keep system safe while temporarily operating and quote repair to vent pipe three 5 foot sections of 4” pipe and 3 90° 4” standard 1 90° 4” double

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on 2023 Daikin gas furnace. 20x25x4 air filter is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Nate G.

Nate G. Job Checkin

Trane clean effects pre-filter light was flashing Push and hold reset cleared that Screws for door clasps were loose Door fitting tightly now


Brandon P.

Brandon P. Job Checkin

Preventative Maintenance Inspection on 2020 Trane S9V2 high efficiency furnace running in great condition. Trane Clean Effects filter incclean condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode on both stages. Temperature rise is within specs. Blower motor and inducer motor amp draw is within specifications. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. Humidifier pad in good condition, damper opened, run test during heating mode. All measurments are within operation parameters. System is operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Replace collector box and associated gaskets to fix water leak. Test ran operation in heating mode.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on 1993 Rheem furnace. A leak was mentioned upon arrival, but no leak was found during inspection. Flushed condensate trap in case that is the issue. Current 16x25x1 air filter in good condition. Check again in 1-2 months. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 3" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. Despite age, system is operating in good condition with no issues found or suspected.


Nate G.

Nate G. Job Checkin

Found ground loop has lost pressure Repressurized loop to 34psi Will send quote to install non-pressurized flow center