Excellent service, repairman came quickly and took care of my problem quickly. very happy with price and everything!
Overall Experience
Quality
Price
Convenience
Seth was great. He was very thorough in performing an annual service for our furnace and AC units.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Seth did an excellent job. He is always easy to work with. I'm glad Westin did the furnace replacement. A great company to work with.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Geothermal replacement. A couple of issues but Westin corrected them all. We used Westin to later replace a humidifier and plan to use them for an HVAC system in a condo we own.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Love , all the staff, and Seth is really great , he cares about the customers, I can tell it’s not an act
Overall Experience
Quality
Price
Convenience
Seth was very professional and courteous. He took the time to explain the new system with me and answered all my questions. He was on time and did quality work.
Overall Experience
Quality
Price
Convenience
Seth is a great guy to have on your team. Doesn't mind if watch and ask questions.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Fit us in the schedule in a few days and fixed our AC at a reasonable price
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Westin Air has been very helpful. They are always on time and courteous. I would recommend them if you need your furnace repaired.
Overall Experience
Quality
Price
Convenience
Propane heating preventative maintenance performed Check filter - 20x25x4 ok Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 56.3 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: ok Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.2 Check amp draw on inducer motor:1.2 Check delta T - 56° propane / 31° heat pump Furnace is in optimal running conditions Inspect heat pump and verify unit is clean and running properly. No concerns with heat pump unit heating well
Furnace throwing a 31 fault intermittently I went down thinking that was high limit fault and began adjusting temperature rise. Admitted mistake to homeowner and verified the code is for the high pressure switch opening. Cannot verify if intake and exhaust are 100% free of obstructions because the flush mount termination kit is glued onto the exhaust pipe (cover should not be glued to anything, it is held on by 4 screws). Homeowner is going to reach out to the builder to see if they will replace the termination cover. Furnace ran for the entire time I was there without throwing a fault code. It cycled back on and off normally with calls for heat. If the intake and exhaust are clear, next step is a parts warranty pressure switch. Verified inducer is pulling 0.6"wc while heating, switch is rated for .35" Did not see any major variations in the pressure, either. Verified inducer capacitor is measuring the rated 5mfd Looked up a Carrier service bulletin TIC2017-0001 regarding nuisance
Install hanging gas unit heater and vent through exterior wall or roof.
Perform Gold preventative maintenence inspection on two Carrier high efficiency furnaces. Both are operating in great condition. 20x25x4 air filter replaced on both units. Installed new humidifier water panel on main system. Replaced ERV filter set with filters on site. Clean flame sensors and check ignitors. Visual inspection of burners. Flush condensation traps and drain lines. Run test each system in gas heating mode. Both systems are operating properly and within specifications for temperature rise, blower and inducer motor amp draw, and manifold gas pressures. Test ran operation of geothermal heating. Did not check refrigerant as there are no issues suspected. Replaced 2X AA batteries in wireless outdoor temperature sensor. All systems are operating properly, efficiently and ready for Winter.
Performed heating maintenance on a 2021 Trane S9V2 96% efficient two stage natural gas furnace Cleaned Trane CleanEffects electronic air cleaner (pre filter, control electrode grid, and collection cells) Reset filter indicator Pulled and cleaned flame sensor Removed all the burners and cleaned with a wire brush Removed condensate trap and flushed with hot water High fire gas pressure 3.5"wc Low fire gas pressure 1.7"wc
Drain was clogged and filling the inducer with water. Cleared the drain Furnace operating normally at this time.
Performed heating maintenance on Daikin 97% efficient modulating natural gas furnace with VRV heat pump Pulled and cleaned flame sensor Blew out Condensate trap Blower clean iWave air ionizer functioning properly Aprilaire 210 air filter is still good until spring time Humidifier water panel is good Checked aprilaire ERV filters and heat exchanger core Checked aprilaire dehumidifier filter and coil Verified drain lines are are flowing properly Temperature rise for gas furnace is within specification No stored fault codes on the system controller Surge protector status light is still green Inspected intake and exhaust vent piping, no signs of leaks UV light status is normal No concerns found on today's visit
Preventative maintenence inspection on Trane S9V2 furnace running in great condition. 20x25x4 air filter is new today. Tested operation of I-Wave air cleaner. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Humidifier pad is new today. Humidistat set to 35%. Test run furnace in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 3" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. Tested operation of humidifier during heating test. All systems are operating properly, efficiently and ready for Winter.
Preventative maintenence inspection on 2021 Bryant high efficiency furnace running in great condition. 20x25x4 air filter in new condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Test run in heating mode from thermostat. Temperature rise is within specs. Manifold gas pressure is within spec. Blower motor and inducer motor running within spec. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.
Replaced humidifier solenoid valve and water panel Verified correct operation and no water leaks
OEM Trane part replacement inducer motor assembly
Diagnosed failing inducer motor on the furnace Tested for carbon monoxide and ran combustion test Furnace is running in OK condition
Performed heating maintenance on a 2014 trane two stage 96% efficient natural gas furnace 16x25x5 filter is new Pulled and cleaned flame sensor Pulled condensate trap and flushed with water Replaced humidifier water panel Humidifier not functioning due to failed solenoid valve Approved proposal for repairs Run tested furnace while running combustion analysis Gas pressure, temperature rise, and combustion numbers are all within manufacturer's specifications
Preventative maintenence inspection on 2010 Trane airhandler. Air filter is in good condition. Checked for any loose wiring in airhandler. Test ran operation of electric heat strips. All heat strips are operating properly. Air handler is operating properly and ready for Winter. Attempted test run of heat pump heating. Found that there is no high voltage to the outdoor unit. Indoor breaker is on, wire is mostly traceable, but it is a different wire coming out of the siding at the heat pump. An electrician will need called with electrical diagnosis. 24v call for contactor is still present. Due to inability to test run heat pump, cannot guarantee that it operates.
Install new OEM ignition module and fan control