Excellent service, repairman came quickly and took care of my problem quickly. very happy with price and everything!
Overall Experience
Quality
Price
Convenience
Seth was great. He was very thorough in performing an annual service for our furnace and AC units.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Seth did an excellent job. He is always easy to work with. I'm glad Westin did the furnace replacement. A great company to work with.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Geothermal replacement. A couple of issues but Westin corrected them all. We used Westin to later replace a humidifier and plan to use them for an HVAC system in a condo we own.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Love , all the staff, and Seth is really great , he cares about the customers, I can tell it’s not an act
Overall Experience
Quality
Price
Convenience
Seth was very professional and courteous. He took the time to explain the new system with me and answered all my questions. He was on time and did quality work.
Overall Experience
Quality
Price
Convenience
Seth is a great guy to have on your team. Doesn't mind if watch and ask questions.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Fit us in the schedule in a few days and fixed our AC at a reasonable price
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Westin Air has been very helpful. They are always on time and courteous. I would recommend them if you need your furnace repaired.
Overall Experience
Quality
Price
Convenience
Preventative maintenence inspection on Trane S9V2 furnace running in great condition. 20x25x4 air filter is new today. Tested operation of I-Wave air cleaner. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Humidifier pad is new today. Humidistat set to 35%. Test run furnace in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 3" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. Tested operation of humidifier during heating test. All systems are operating properly, efficiently and ready for Winter.
Preventative maintenence inspection on 2021 Bryant high efficiency furnace running in great condition. 20x25x4 air filter in new condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Test run in heating mode from thermostat. Temperature rise is within specs. Manifold gas pressure is within spec. Blower motor and inducer motor running within spec. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.
Replaced humidifier solenoid valve and water panel Verified correct operation and no water leaks
OEM Trane part replacement inducer motor assembly
Diagnosed failing inducer motor on the furnace Tested for carbon monoxide and ran combustion test Furnace is running in OK condition
Performed heating maintenance on a 2014 trane two stage 96% efficient natural gas furnace 16x25x5 filter is new Pulled and cleaned flame sensor Pulled condensate trap and flushed with water Replaced humidifier water panel Humidifier not functioning due to failed solenoid valve Approved proposal for repairs Run tested furnace while running combustion analysis Gas pressure, temperature rise, and combustion numbers are all within manufacturer's specifications
Preventative maintenence inspection on 2010 Trane airhandler. Air filter is in good condition. Checked for any loose wiring in airhandler. Test ran operation of electric heat strips. All heat strips are operating properly. Air handler is operating properly and ready for Winter. Attempted test run of heat pump heating. Found that there is no high voltage to the outdoor unit. Indoor breaker is on, wire is mostly traceable, but it is a different wire coming out of the siding at the heat pump. An electrician will need called with electrical diagnosis. 24v call for contactor is still present. Due to inability to test run heat pump, cannot guarantee that it operates.
Install new OEM ignition module and fan control
Preventative maintenence inspection on 2019 Bryant high efficiency furnace. System is running in great condition. 16x25x4 air filter is in good condition. Replaced #10 humidifier pad. Clean flame sensor and check ignitor @ 51ohms. Flushed out collector box drain trap. Test ran furnace in first and second stage heating. Both stages are operating with gas manifold pressure specifications and temperature rise specifications. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Blower and inducer motors tested good. Humidifier is operational and damper is open. System is operating properly, efficiently and ready for Winter.
Install Daikin Aurora Ductless System *Variable Speed Heat Pump: Model #: RXT15AVJU9 Serial #: 7009768 15,000 BTU's 19.5 SEER2 - 11.5 EER2 - 9.7 HSPF2 Heating Operation at -13 Degrees & Above *Daikin Wall Mounted Air Handler Model #: FTXV15AVJU9 Serial #: Y000610 Installation: * Additional Services - Electrical Services - Install New Electric to Outdoor Unit * Installation of electric wiring whip & disconnect * Start up and commission new system Warranty: 12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
Preventative maintenence inspection on Climatemaster Geothermal unit. Air filter is in clean condition. Air coils is in clean condition. Tested operation of electric heat strips. All strips are operating properly. Tested operation of geo heating. All parameters Tested within spec. Blower motor is operating properly. Zone panel is operating properly. Tested operation of humidifier. Turned on water supply, set humidistat to 40%, and opened damper. Current humidifier pad is in good condition. All systems tested within specifications and unit is ready for Winter.
Goodman single stage furnace locked out ignition attempts Reset power Gas valve not opening Verified 24V present at gas valve Put wires back and gas valve began operating normally Jostling the electronics on the gas valve causes interruption in operation Recommend replacing the gas valve to prevent further malfunction Furnace is currently operating Discussed maintenance plans, discounts and repairs Currently in contract with another company who would not respond to emergency service After canceling existing contract, will sign up for gold plan and replace gas valve. Ideally, on the return visit, perform heating maintenance and replace the gas valve at the same time.
Looked at 3 Reznor unit heaters One has two small cracks in the heat exchanger, but it is operational Discussed carbon monoxide risks Other unit needs a new spark module and fan control thermostatic switch. Third unit had a bad thermocouple. Replaced thermocouple Unit is operating normally at this time.
2010 Bryant single stage 93% efficient natural gas furnace. Tripped out on a 31 fault, pressure switch stuck open Found secondary heat exchanger full of water Removed condensate trap Washed trap out thoroughly in the sink 20x25x1 Filter is brand new Flame sensor appears to have been cleaned very recently (yesterday?) Set gas pressure to 3.2"wc with reference to the burner box Ran combustion test (readings are attached to this invoice) Furnace is operating within factory specifications at this time. Signed up for silver maintenance plan Approved drain line modifications for AC condensate drain: removed p-trap (point of clogging for AC condensate), replaced cut section of pipe and installed a vent Tee fitting.