725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for galena, oh

Rated 4.9 out of 5 stars based on 17 customer reviews

Great service!

Excellent service, repairman came quickly and took care of my problem quickly. very happy with price and everything!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Seth was great. He was very thorough in performing an annual service for our furnace and AC units.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Couldn’t do without Seth

  • Overall Experience
  • Quality
  • Price
  • Convenience

Annual Maintenance

Seth did an excellent job. He is always easy to work with. I'm glad Westin did the furnace replacement. A great company to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

arrived late

  • Overall Experience
  • Quality
  • Price
  • Convenience

Made everything right

Geothermal replacement. A couple of issues but Westin corrected them all. We used Westin to later replace a humidifier and plan to use them for an HVAC system in a condo we own.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Love , all the staff, and Seth is really great , he cares about the customers, I can tell it’s not an act

  • Overall Experience
  • Quality
  • Price
  • Convenience

Seth was very professional and courteous.

Seth was very professional and courteous. He took the time to explain the new system with me and answered all my questions. He was on time and did quality work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great tech

Seth is a great guy to have on your team. Doesn't mind if watch and ask questions.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Happy customer!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great work

Perfect

  • Overall Experience
  • Quality
  • Price
  • Convenience

Would choose them again

Fit us in the schedule in a few days and fixed our AC at a reasonable price

  • Overall Experience
  • Quality
  • Price
  • Convenience

great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Westin Air has been very helpful. They are always on time and courteous. I would recommend them if you need your furnace repaired.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for galena, oh

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane standard efficiency gas furnace running in great condition. 20x25x4 air filter in decent condition. Check again in 1-2 months. Humidifier pad is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. Galvanized B-vent is in good condition and no sign of leaks. 0PPM CO detected during testing. Test ran humidifier operation. All systems are operating properly, efficiently and ready for Winter.


Nate G.

Nate G. Job Checkin

Replaced blower capacitor on 1993 Trane 80% propane furnace Has a 5 series geo split and a 5 series package unit Pressurized closed loop


Nate G.

Nate G. Job Checkin

Heat exchanger failed Propane wants quotes for full system and furnace only Furnace and AC Furnace and heat pump Bryant and Daikin options for full system replacements Include price option for bypass humidifier Floor to supply trunk 62" high 21" wide 50' line set 50' exhaust 8x24 return drop Siemens breaker panel 30A currently for outdoor unit

Heat exchanger failed
Propane
wants quotes for full system and furnace only
Furnace and AC
Furnace and heat pump 
Bryant and Daikin options for full system replacements
Include price option for bypass humidifier


Floor to supply trunk 62" high
21" wide
50' line set 
50' exhaust 
8x24 return drop
Siemens breaker panel 30A currently for outdoor unit Heat exchanger failed
Propane
wants quotes for full system and furnace only
Furnace and AC
Furnace and heat pump 
Bryant and Daikin options for full system replacements
Include price option for bypass humidifier


Floor to supply trunk 62" high
21" wide
50' line set 
50' exhaust 
8x24 return drop
Siemens breaker panel 30A currently for outdoor unit

Graham M.

Graham M. Job Checkin

Inspected furnace for cause of overheating and found no major concerns with unit gas pressure at 3.10 blower speeds on high. Filter was clogged with white dust suspected from humidifiers. Advised to run purified water or replace humidifiers with a whole house installed in the hvac. Found loose exhaust clamp for furnace. Tightened clamp down and informed homeowner of concern. Advised maintenance should be performed 2 times a year once spring once fall.


Nate G.

Nate G. Job Checkin

69.6 return 89.7 supply 41.3 psi in 38.7 psi out 32.7⁰ in 27.0⁰ out 10gpm Heat of extraction 27,000 Suction pressure 81.7psi Per thr performance charts, system is operating normally.

69.6 return
89.7 supply
41.3 psi in 
38.7 psi out
32.7⁰ in
27.0⁰ out
10gpm
Heat of extraction 27,000
Suction pressure 81.7psi
Per thr performance charts, system is operating normally.

Nate G.

Nate G. Job Checkin

Performed two system heating maintenance Main furnace: 2020 Trane 2 stage 80% efficient natural gas furnace Trane clean effects electronic filter on schedule with homeowners: verified clean and internal components in good shape Aprilaire #35 humidifier water panel on schedule with homeowners: current water panel OK Adjusted pitch to humidifier drain behind the furnace, it was going uphill towards the drain outlet Pulled flame sensor and cleaned Pulled pressure switch tubing and cleared the port Burners are in great shape Blower wheel in clean condition, no vibrations from it Exhaust piping in good shape 0ppm carbon monoxide around the furnace and water heater venting during furnace operation No concerns found Second furnace: 2016 Trane 2 stage 96% efficient natural gas furnace Trane clean effects in good shape Aprilaire water panel in good shape Drain lines clear for furnace and humidifier Blew out Condensate drain trap for the furnace Intake air screen free of debris Pulled and

Performed two system heating maintenance

Main furnace: 
2020 Trane 2 stage 80% efficient natural gas furnace
Trane clean effects electronic filter on schedule with homeowners: verified clean and internal components in good shape
Aprilaire #35 humidifier water panel on schedule with homeowners: current water panel OK
Adjusted pitch to humidifier drain behind the furnace, it was going uphill towards the drain outlet
Pulled flame sensor and cleaned 
Pulled pressure switch tubing and cleared the port
Burners are in great shape
Blower wheel in clean condition, no vibrations from it
Exhaust piping in good shape
0ppm carbon monoxide around the furnace and water heater venting during furnace operation
No concerns found

Second furnace:
2016 Trane 2 stage 96% efficient natural gas furnace 
Trane clean effects in good shape
Aprilaire water panel in good shape 
Drain lines clear for furnace and humidifier
Blew out Condensate drain trap for the furnace
Intake air screen free of debris
Pulled and Performed two system heating maintenance

Main furnace: 
2020 Trane 2 stage 80% efficient natural gas furnace
Trane clean effects electronic filter on schedule with homeowners: verified clean and internal components in good shape
Aprilaire #35 humidifier water panel on schedule with homeowners: current water panel OK
Adjusted pitch to humidifier drain behind the furnace, it was going uphill towards the drain outlet
Pulled flame sensor and cleaned 
Pulled pressure switch tubing and cleared the port
Burners are in great shape
Blower wheel in clean condition, no vibrations from it
Exhaust piping in good shape
0ppm carbon monoxide around the furnace and water heater venting during furnace operation
No concerns found

Second furnace:
2016 Trane 2 stage 96% efficient natural gas furnace 
Trane clean effects in good shape
Aprilaire water panel in good shape 
Drain lines clear for furnace and humidifier
Blew out Condensate drain trap for the furnace
Intake air screen free of debris
Pulled and

Graham M.

Graham M. Job Checkin

replace HPS on waterfurnace with 600psi thread on fitting and T fitting between it and the lineset to allow pressure taps still accessible. Install blower motor and test run heat. Unit running with electric heat and 2stage compressor, should get house temp back up within the next hour or two.

replace HPS on waterfurnace with 600psi thread on fitting and T fitting between it and the lineset to allow pressure taps still accessible. Install blower motor and test run heat. Unit running with electric heat and 2stage compressor, should get house temp back up within the next hour or two.

Graham M.

Graham M. Job Checkin

Unit tucked away in a very tight closet. Had to dig lots of things out of closet in order to access unit, air mattress, comforter, paper towel rolls, pillows, and toilet paper rolls Inspected unit and found mouse nest inside of heating element compartment. Mouse was hanging from element hookups and short circuiting unit. Remove mouse and test run system. Vacuum nest debris to deter future nesting. Comforter in closet seemed to be a source for nest I would recommend trashing it and sealing any openings on room allowing mice in.

Unit tucked away in a very tight closet. Had to dig lots of things out of closet in order to access unit, air mattress, comforter, paper towel rolls, pillows, and toilet paper rolls Inspected unit and found mouse nest inside of heating element compartment. Mouse was hanging from element hookups and short circuiting unit. Remove mouse and test run system. Vacuum nest debris to deter future nesting. Comforter in closet seemed to be a source for nest I would recommend trashing it and sealing any openings on room allowing  mice in. Unit tucked away in a very tight closet. Had to dig lots of things out of closet in order to access unit, air mattress, comforter, paper towel rolls, pillows, and toilet paper rolls Inspected unit and found mouse nest inside of heating element compartment. Mouse was hanging from element hookups and short circuiting unit. Remove mouse and test run system. Vacuum nest debris to deter future nesting. Comforter in closet seemed to be a source for nest I would recommend trashing it and sealing any openings on room allowing  mice in.

Nate G.

Nate G. Job Checkin

5 year labor warranty Water to water geo locking out on FP1 Dipswitch was set to 30⁰ Switched to 15⁰ Monitored FP1 temperature, went no colder than 27⁰ with both geo systems operating at the same


Jason D.

Jason D. Job Checkin

01/23/2026 9:51:37 AM - Option 1 Install New Bryant Single (2) Stage Gas Furnace Model #: 927TA48080V17 Serial #: 80,000 BTU’s - 97% AFUE Installation: * Additional Services - New PVC furnace vents. Level 2 * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system * 1" Standard Filter Rack Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)


01/23/2026 9:51:37 AM - Option 1

Install New Bryant Single (2) Stage Gas Furnace
Model #: 927TA48080V17
Serial #: 
80,000 BTU’s - 97% AFUE
 
Installation:
* Additional Services - New PVC furnace vents. Level 2 
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* 1" Standard Filter Rack
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

01/23/2026 9:51:37 AM - Option 1

Install New Bryant Single (2) Stage Gas Furnace
Model #: 927TA48080V17
Serial #: 
80,000 BTU’s - 97% AFUE
 
Installation:
* Additional Services - New PVC furnace vents. Level 2 
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* 1" Standard Filter Rack
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

Graham M.

Graham M. Job Checkin

Upon arrival inspected system and found in limit fault. Inspected filter and filter was clean dated 12/3/25 humidifier bypass open unit producing 78° rise. Unsure of cause of shift in temperature rise. Adjust gas pressure down to 3.2 and adjust blower speeds to allow 10% more airflow during heat. check temp rise now doing 65°. Unit only went into limit fault from extending runtime with extended demand from lots of in and out traffic. Gas pressure being 3.6 temp rise being high with clean filter remove diag fee


Graham M.

Graham M. Job Checkin

Upon arrival inspected system and found unit in lockout E2. Inspected pressure on refrigerant system and unit at 197 psi on high side, sensor reading OL will not close. Jumped wires until we can return with a new pressure switch. Unit will still have over amperage protection until then.

Upon arrival inspected system and found unit in lockout E2. Inspected pressure on refrigerant system and unit at 197 psi on high side, sensor reading OL will not close. Jumped wires until we can return with a new pressure switch. Unit will still have over amperage protection until then. Upon arrival inspected system and found unit in lockout E2. Inspected pressure on refrigerant system and unit at 197 psi on high side, sensor reading OL will not close. Jumped wires until we can return with a new pressure switch. Unit will still have over amperage protection until then.

Graham M.

Graham M. Job Checkin

Found no concerns with geo unit has no errors currently. Thermostat set to run furnace after 20° and below Ron requested it be at 30° below fp1 downstairs set to 15° pump reservoir full and pumping unit is working with no concerns at this time.


Jason D.

Jason D. Job Checkin

replacement warranty


Nate G.

Nate G. Job Checkin

Replace Waterfurnace FP1 sensor Install aftermarket High pressure switch and service tee Also fixed thermostat wire splice that wasn't allowing Y2 to energize at the geo


Replace Waterfurnace FP1 sensor 
Install aftermarket High pressure switch and service tee

Also fixed thermostat wire splice that wasn't allowing Y2 to energize at the geo 
Replace Waterfurnace FP1 sensor 
Install aftermarket High pressure switch and service tee

Also fixed thermostat wire splice that wasn't allowing Y2 to energize at the geo