725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for galena, oh

Rated 4.9 out of 5 stars based on 17 customer reviews

Great service!

Excellent service, repairman came quickly and took care of my problem quickly. very happy with price and everything!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Seth was great. He was very thorough in performing an annual service for our furnace and AC units.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Couldn’t do without Seth

  • Overall Experience
  • Quality
  • Price
  • Convenience

Annual Maintenance

Seth did an excellent job. He is always easy to work with. I'm glad Westin did the furnace replacement. A great company to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

arrived late

  • Overall Experience
  • Quality
  • Price
  • Convenience

Made everything right

Geothermal replacement. A couple of issues but Westin corrected them all. We used Westin to later replace a humidifier and plan to use them for an HVAC system in a condo we own.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Love , all the staff, and Seth is really great , he cares about the customers, I can tell it’s not an act

  • Overall Experience
  • Quality
  • Price
  • Convenience

Seth was very professional and courteous.

Seth was very professional and courteous. He took the time to explain the new system with me and answered all my questions. He was on time and did quality work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great tech

Seth is a great guy to have on your team. Doesn't mind if watch and ask questions.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Happy customer!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great work

Perfect

  • Overall Experience
  • Quality
  • Price
  • Convenience

Would choose them again

Fit us in the schedule in a few days and fixed our AC at a reasonable price

  • Overall Experience
  • Quality
  • Price
  • Convenience

great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Westin Air has been very helpful. They are always on time and courteous. I would recommend them if you need your furnace repaired.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for galena, oh

Graham M.

Graham M. Job Checkin

Upon arrival inspected unit and found low on R410a. Unit severely low at 30psi suction and 120psi liquid. Quote to add refrigerant and inform homeowner of large leak. Unsure of current location she wants a leak search done at a return visit, getting unit back going today unit took 2lbs r410a my van stock was down to that last 2lbs - grabbed another jug R410 from office - add additional 1lbs r410a to get system cooling properly until return visit for leak search. Beverly said she will call the office Monday


Jason D.

Jason D. Job Checkin

Install WaterFurnace 5 Series Geothermal system. 2 Stage compressor, Variable Speed ECM blower -Model #W5AV060BD1A12CTL2B10 Serial# 250801916 Efficiency: Up to 5.0 COP / 30.0 EER Features Included: *Aurora Advanced Controls *20KW Backup heat *2" Merv 11 air filter *2 pump GeoLink loop flow center *Vision Pro 8000 WiFi thermostat Installation: *Reconnect to existing loop and top off antifreeze as needed. *Reconnect to existing high voltage electrical circuit *Transition to existing supply and return duct *Reconnect hot water generation to existing water tank Warranty: (Annual maintenance must be performed) WaterFurnace 10 Year Parts WaterFurnace 5 Year Labor Flow Center and Accessories 5 Year Parts and Labor Warranty does not cover existing loop field or antifreeze.. Optional accessories: Air Scrubber by Activepure - Air Purifier - ADD $925 *** 30% Federal Tax Credit Eligible *** 2% Cash/Check Discount Available **Westin Air Not Responsible for Defects with Existing Equipment and


Install WaterFurnace 5 Series Geothermal system. 2 Stage compressor, Variable Speed ECM blower
-Model #W5AV060BD1A12CTL2B10
Serial# 250801916
Efficiency: Up to 5.0 COP / 30.0 EER
Features Included:
*Aurora Advanced Controls
*20KW Backup heat
*2" Merv 11 air filter
*2 pump GeoLink loop flow center
*Vision Pro 8000 WiFi thermostat

Installation:
*Reconnect to existing loop and top off antifreeze as needed.
*Reconnect to existing high voltage electrical circuit
*Transition to existing supply and return duct
*Reconnect hot water generation to existing water tank

Warranty: (Annual maintenance must be performed)
WaterFurnace 10 Year Parts
WaterFurnace 5 Year Labor
Flow Center and Accessories 5 Year Parts and Labor
Warranty does not cover existing loop field or antifreeze..

Optional accessories:
Air Scrubber by Activepure -  Air Purifier - ADD $925

*** 30% Federal Tax Credit Eligible
*** 2% Cash/Check Discount Available

**Westin Air Not Responsible for Defects with Existing Equipment and

seth p.

seth p. Job Checkin

After homeowner move in 2 days ago the system completely quit working and is locking out on high refrigerant pressure due to an empty non-pressurized flow center After one attempt to refill the np2 flow center with constant fresh water from the water heater no return pressure was ever observed. After discussions with multiple people on the property and construction workers at the street a discovery was made that the Delco fire hydrant installation contractor had severed the geothermal horizontal ground loop pipes traveling parallel to Worthington road Homeowners have been given contact information for Jackson geothermal and Crabtree drilling, two of Westin Air's preferred contractors for all outside of the house work Depending on the contractor used and the service provided to repair the outside damage, Westin Air is capable of flushing and filling the ground loop circuit with propylene glycol to a freeze protection rate of +10° to +20°f Pressure testing during the flush and fill


seth p.

seth p. Job Checkin

2003/04 Trane XL 14 heating and cooling system first floor main level system Homeowners concerns of long run times and moderate temperatures are confirmed with low refrigerant pressures and a visual frosting over of the indoor evaporator coil. System has developed a R22 refrigerant leak that is non-repairable with obsolete equipment Due to the age and current condition of the equipment along with dropping temperatures in the September fall season the homeowner has chosen NOT to recharge the system at this time. An estimated $800 - $1200 would be required for up to 9 lb of R422b and one leak stop dye pack Suction pressure is currently running in the high 40s to low 50s with no heat load. System is by no means empty but the required amount for a full functioning system is unknown. Replacement equipment or Leak stop with recharge are the only available options for this system. Office staff will review the photos of the equipment and contact the homeowner regarding scheduling a fre

2003/04 Trane XL 14 heating and cooling system first floor main level system
Homeowners concerns of long run times and moderate temperatures are confirmed with low refrigerant pressures and a visual frosting over of the indoor evaporator coil. 
System has developed a R22 refrigerant leak that is non-repairable with obsolete equipment 
Due to the age and current condition of the equipment along with dropping temperatures in the September fall season the homeowner has chosen NOT to recharge the system at this time. 
An estimated $800 - $1200 would be required for up to 9 lb of R422b and one leak stop dye pack 
Suction pressure is currently running in the high 40s to low 50s with no heat load. System is by no means empty but the required amount for a full functioning system is unknown. 

Replacement equipment or Leak stop with recharge are the only available options for this system. 

Office staff will review the photos of the equipment and contact the homeowner regarding scheduling a fre

Jason D.

Jason D. Job Checkin

Install new single zone Daikin Aurora ductless system. Indoor Model# FTXV09AVJU9 Aurora Single Zone Wall Mounted Indoor unit. R-32 Serial# Y252225 Outdoor Model# RXT09AVJU9 Aurora Single Zone Heat Pump R-32 Serial# Y007701 Includes: *Wireless remote control *Refrigerant line set *Condensate drain *Reconnect to existing high voltage circuit for outdoor unit 12 Year Daikin manufacturers parts warranty 2 Year Westin Air labor warranty


Nate G.

Nate G. Job Checkin

Disabled wifi for the vision pro thermostats Mini splits, explained they both must be in heat mode. Also Bypassed the generac load shed contactor for the mini split


Nate G.

Nate G. Job Checkin

Two Honeywell VisionPro8000 thermostats Replace collector box on both furnaces


Nate G.

Nate G. Job Checkin

Performed two system cooling maintenance Found both electronic air cleaners are non-functional These have a paper cartridge that is replaceable, so at this point they're just standard air cleaners Quoted repair and replacement of the air cleaners, decided to leave it alone for now Found both furnaces have cracked collector boxes, approved quote to replace the failed parts Requested wifi thermostats, approved quote for those Checked outdoor units Capacitors in spec Coils are clean Refrigerant charges ok

Performed two system cooling maintenance 
Found both electronic air cleaners are non-functional 
These have a paper cartridge that is replaceable, so at this point they're just standard air cleaners
Quoted repair and replacement of the air cleaners, decided to leave it alone for now
Found both furnaces have cracked collector boxes, approved quote to replace the failed parts
Requested wifi thermostats, approved quote for those
Checked outdoor units
Capacitors in spec
Coils are clean
Refrigerant charges ok

seth p.

seth p. Job Checkin

Replace IntelliStart compressor start capacitor device Four step geothermal air coil cleaning


Brandon P.

Brandon P. Job Checkin

Replace failed ecm motor with new oem ecm motor. Test run operation for fan only and ac operation. Blower system is operating properly at this time.


Brandon P.

Brandon P. Job Checkin

Did not hear noise while on site. Blower motor is in the stages of failing. 10uf capacitor is reading 8.7uf, there is visible oil staining on the oside of the motor body from a failed bearing, and loud vibrating/rubbing noise upon motor startup. Quotes for replacement will include oem motor replacement , and universal motor replacement.

Did not hear noise while on site. Blower motor is in the stages of failing. 10uf capacitor is reading 8.7uf, there is visible oil staining on the oside of the motor body from a failed bearing, and loud vibrating/rubbing noise upon motor startup. Quotes for replacement will include oem motor replacement , and universal motor replacement.

Brandon P.

Brandon P. Job Checkin

Perform leak search to attempt to find leak. Finding the leak is not guaranteed. If the leak is found, repairs are not guaranteed either. Any repairs, if possible, will be quoted separately after the leak search is performed and only if the leak is found, and repairable. Found area of leak in a non repairable spot on the indoor air coils. System can be charged up for temporary cooling, but replacement is highly recommended at this point. Charge in 5lbs of new r410a refrigerant to bring system back to factory operating specs. Leak stop/UV dye cannot be added again as it has already been added to the system prior to today.

Perform leak search to attempt to find leak. Finding the leak is not guaranteed. If the leak is found, repairs are not guaranteed either. Any repairs, if possible, will be quoted separately after the leak search is performed and only if the leak is found, and repairable.

Found area of leak in a non repairable spot on the indoor air coils. System can be charged up for temporary cooling, but replacement is highly recommended at this point. 

Charge in 5lbs of new r410a refrigerant to bring system back to factory operating specs. Leak stop/UV dye cannot be added again as it has already been added to the system prior to today.

Brandon P.

Brandon P. Job Checkin

Inspection of furnace shows that blower motor is non operational. Control board is sending proper 120v and 24v but blower motor is not doing anything. Prepared quote and sent over estimate.

Inspection of furnace shows that blower motor is non operational. Control board is sending proper 120v and 24v but blower motor is not doing anything. Prepared quote and sent over estimate.

Graham M.

Graham M. Job Checkin

Upon arrival homeowner informed me of unit freezing outside and having to be shut off. Started unit up and inspected outdoor unit and found low on r22. Quote r22 recharge was approved, add 3lbs r422D r22 substitute. Unit is back cooling with 230psi-16°/63psi-17° Unit is 20 years old, coil is deteriorating outside. Unit should be considered for replacement soon. Homeowners also potentially interested in mini split addition to 2nd floor due to lack of cooling capacity upstairs.


Graham M.

Graham M. Job Checkin

Upon arrival inspected unit and found compressor not operational. Inspected 45+5 capacitor tested 5.0+3.25 replaced new today. Believe the condenser coil being clogged was a cause of taking out capacitor along with very hot days lately so extended runtime. System checked out okay after coil was cleaned and capacitor was replaced.