725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for galena, oh

Rated 4.9 out of 5 stars based on 17 customer reviews

Great service!

Excellent service, repairman came quickly and took care of my problem quickly. very happy with price and everything!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Seth was great. He was very thorough in performing an annual service for our furnace and AC units.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Couldn’t do without Seth

  • Overall Experience
  • Quality
  • Price
  • Convenience

Annual Maintenance

Seth did an excellent job. He is always easy to work with. I'm glad Westin did the furnace replacement. A great company to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

arrived late

  • Overall Experience
  • Quality
  • Price
  • Convenience

Made everything right

Geothermal replacement. A couple of issues but Westin corrected them all. We used Westin to later replace a humidifier and plan to use them for an HVAC system in a condo we own.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Love , all the staff, and Seth is really great , he cares about the customers, I can tell it’s not an act

  • Overall Experience
  • Quality
  • Price
  • Convenience

Seth was very professional and courteous.

Seth was very professional and courteous. He took the time to explain the new system with me and answered all my questions. He was on time and did quality work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great tech

Seth is a great guy to have on your team. Doesn't mind if watch and ask questions.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Happy customer!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great work

Perfect

  • Overall Experience
  • Quality
  • Price
  • Convenience

Would choose them again

Fit us in the schedule in a few days and fixed our AC at a reasonable price

  • Overall Experience
  • Quality
  • Price
  • Convenience

great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Westin Air has been very helpful. They are always on time and courteous. I would recommend them if you need your furnace repaired.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for galena, oh

Nate G.

Nate G. Job Checkin

Diagnosed system low on refrigerant. Agreed leak search and repair is not worth the money considering age and condition of the system. Wanting to replace the AC system

Diagnosed system low on refrigerant.  Agreed leak search and repair is not worth the money considering age and condition of the system.

Wanting to replace the AC system

Nate G.

Nate G. Job Checkin

Performed cooling maintenance on a trane AC system Filter is good, recommend Honeywell 20x25x4 MERV8 filters to reduce strain on the blower motor He had a new water panel for the humidifier and requested I replace it today. Blower is clean Drain is clear Outdoor coil was pretty dirty with pollen Thoroughly washed the coil Refrigerant charge 12⁰ subcool, spec is 10⁰ +/-3⁰ Capacitor in spec Wiring secure and no signs of damage to conductor insulation No concerns found on today's visit


Graham M.

Graham M. Job Checkin

Cooling preventative maintenance performed Check filter - 16x25x4 new today Check coil for any buildup or debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD -45+5 @ 43.02+4.92 Check OD fan Amp - 0.52 Check compressor Amp - 7.83 Verify pressures and HP-SC/LP-SH Delta T - 21° The Air handler and AC are in optimal running conditions.

Cooling preventative maintenance performed
Check filter - 16x25x4 new today
Check coil for any buildup or debris in drain pan and flush with water
Set up thermometers
Rinse down outdoor coil with garden hose
Check capacitor MFD -45+5 @ 43.02+4.92
Check OD fan Amp - 0.52
Check compressor Amp - 7.83
Verify pressures and HP-SC/LP-SH
Delta T - 21°
The Air handler and AC are in optimal running conditions.

Nate G.

Nate G. Job Checkin

Diagnosed low refrigerant on Mitsubishi Mini Split heat pump Checked field flare connections. No signs of oil. Leak is likely in the indoor or outdoor unit. Agreed to leak sealant and a recharge Unit is cooling properly at this time. Also hosed off outdoor coil


seth p.

seth p. Job Checkin

2009 climate Master geothermal second floor system. Two stage three ton wired to run high stage full time. Equipment is very low on refrigerant charge with 78 PSI suction pressure. Freezing evaporator coil and homeowner says ice has been on the line set in the past. Visual inspection discovered a leaking high pressure service port Schrader core. Oil, crusty debris, and dripping oil are all present. Replace Schrader core Repressurize with 54 Oz new or 410A Inject Max seal leak stop with ultraviolet dye Run test cooling mode. New refrigerant pressures are 110 and 257 with 16 superheat & 13 subcooling. Non pressurized flow center is maintenanced by homeowners and kept full, air filter is on schedule All equipment is back up to proper working condition. Any new refrigerant leaks can be monitored in the future with ultraviolet dye detection but NO follow-up is recommended at this time


Nate G.

Nate G. Job Checkin

Diagnosed failed capacitor on a Goodman 4 ton single stage AC Replaced dual capacitor System operating normally at this time


Nate G.

Nate G. Job Checkin

Performed cooling maintenance on Daikin VRV heat pump Replaced UV light assembly. Replaced aprilaire 210 filter Aprilaire dehumidifier filter is clean Drain lines are clear Noise that was pointed out last year but unable to locate was happening today. Pinpointed it to the dehumidifier drain line. Opened the vent tee on the drain, noise stopped. Blower is clean on the furnace Drain is clear for the furnace, AC, and humidifier Getting a 21⁰ drop across indoor coil in cooling mode Outdoor coil was very dirty with pollen Washed outdoor coil with water Everything is in great shape and operating properly at this time


Brandon P.

Brandon P. Job Checkin

Thermostat put jnto heating mode. Once in roof, flames and inducer all come on as should. Blower motor fails to come on properly and is jitterbug back and forth while making squeaking noise. Will have to get quote for parts and call back with repair quote. this was completed on 02/26/24 but put on hold, the repair has already been made. zeroing out this invoice and completing with Justins approval on 06/04/25

Thermostat put jnto heating mode. 

Once in roof, flames and inducer all come on as should. Blower motor fails to come on properly and is jitterbug back and forth while making squeaking noise. Will have to get quote for parts and call back with repair quote. 

this was completed on 02/26/24 but put on hold, the repair has already been made. zeroing out this invoice and completing with Justins approval on 06/04/25

Brandon P.

Brandon P. Job Checkin

Faulty condenser fan motor is pulling high amps and not operating when a call for cooling is present. 80/5 capacitor is within specs and new from 2023. Condenser fan motor will need replaced. Compressor will operate for a few minutes before tripping on high pressure and shutting the system off for approximately 1-2 minutes and then will continue the cycle. Replace current failed condenser fan motor with new universal condenser fan motor. Test run in cooling from thermostat. No other issues suspected at this time.

Faulty condenser fan motor is pulling high amps and not operating when a call for cooling is present. 80/5 capacitor is within specs and new from 2023. Condenser fan motor will need replaced. Compressor will operate for a few minutes before tripping on high pressure and shutting the system off for approximately 1-2 minutes and then will continue the cycle. 
Replace current failed condenser fan motor with new universal condenser fan motor. Test run in cooling from thermostat. No other issues suspected at this time.

Nate G.

Nate G. Job Checkin

Performed cooling maintenance Filter is good Blower is clean No water leaks present from furnace or AC Drain is clear Washed outdoor coil Capacitor in spec Refrigerant charge in spec Wiring in good shape No concerns found on today's visit


Jason D.

Jason D. Job Checkin

See Notes


seth p.

seth p. Job Checkin

9\2020 Trane XR Overheated and swollen OEM dual run capacitor on outdoor unit Solid matting on spiny fin condenser coils Confirm parts warranty and replace 370 volt power supply 45/5 UF Partial disassembly and water flush condenser coil. Condenser should be 3 in above final grade for proper drainage and snow protection currently the top of the 3-in permapad is below the mulch level Recommend annual maintenance


Nate G.

Nate G. Job Checkin

Geothermal control board replacement Run tested. System operational now


seth p.

seth p. Job Checkin

Water furnace 5 series 6 ton 072 open loop 12 gpm Intellizone generation 1 Clean and flush drain system, inspect space guard air filter and return to service, light dusting of indoor air coil, open loop discharge line TACO zone century zone valve functioning normal and well pumps are maintaining 60 PSI, minor maintenance cleaning of complete system All equipment is clean safe and ready for summer Condensation and or well water has destroyed the hose kit insulation between the Geo and the valve assembly enclosure on both lines. Recommend replacing 1-in armaflex including adding new inside of the valve assembly enclosure


Nate G.

Nate G. Job Checkin

Performed cooling maintenance on a Trane AC system Cleaned CleanEffects electronic air cleaner and reset reminder Blower clean Drain clear Washed outdoor unit and coil with coil cleaner and water Verified refrigerant charge is in spec: 7.7⁰ subcool (calls for 8⁰ +/-3⁰) Capacitor within tolerance Wiring is secure, free of overheating and fraying Did remove a dead mouse from the unit: did not see any damage caused by it System is clean and ready for summer