Excellent service, repairman came quickly and took care of my problem quickly. very happy with price and everything!
Seth was great. He was very thorough in performing an annual service for our furnace and AC units.
Seth did an excellent job. He is always easy to work with. I'm glad Westin did the furnace replacement. A great company to work with.
Geothermal replacement. A couple of issues but Westin corrected them all. We used Westin to later replace a humidifier and plan to use them for an HVAC system in a condo we own.
Love , all the staff, and Seth is really great , he cares about the customers, I can tell it’s not an act
Seth was very professional and courteous. He took the time to explain the new system with me and answered all my questions. He was on time and did quality work.
Seth is a great guy to have on your team. Doesn't mind if watch and ask questions.
Fit us in the schedule in a few days and fixed our AC at a reasonable price
Westin Air has been very helpful. They are always on time and courteous. I would recommend them if you need your furnace repaired.
2021 Bryant AC is running in good condition. 20x25x4 air filter in good condition. Visual inspection of indoor coil. Flush drain pan and drain lines. Run test unit in cooling mode from thermostat. System was low on refrigerant at start of service with a Subcool of 0.7F, when data sheet calls for 10F SC +/-3F. Water flushed outdoor coils to ensure dirty coil was not affecting subcool readings. Due to unit being installed fairly recently, I suspect that system was undercharged from install. Due to not having any service history of the unit, we can not say for certain that there is no leaks. Charged unit with 17oz of R-410A to bring subcool withn the 7-13F range. Current refrigerant pressures are within spec. High 280psi with 11F SC, low 120psi with 8F SH. 45/5 dual run capacitor is reading within spec. Outdoor fan motor and compressor are operating within Amp draw specifications. System is operating properly, efficiently and ready for Summer.
2020 Trane XR AC running in great condition. 20x25x4 air filter in good condition. Visual inspection of indoor coil. Flush drain pan and drain lines. Test I-Wave operation. Test run unit in cooling mode from Nest thermostat. Delta t of 20F with supply temp of 49F. Refrigerant pressures are within spec, high 240psi with 12F SC, low 110psi with 18F SH. Outdoor condenser coils are in clean condition. 70/7.5uf dual run capacitor is within spec. Fan motor and compessor are operating within Amp draw specifications. System is operating properly, efficiently and ready for Summer.
Initial inspection found overheated and swollen compressor capacitor. Electrical readings of the capacitor are rated at $370 volts with 45 microfarads, the system is reading 10.1 MFD. Upon arrival the thermostat was turned off with no service codes active or in lockout. The LED terminal strip and comforter alert are in standby mode. After replacing the compressor capacitor and testing the ground loop water pressure the system ran good with 87° supply temperature in heat pump mode. Hotwire test run 15 KW electric auxiliary heat and confirm 60 amps Replace two AA batteries in the Waterfurnace brand Emerson multi-stage heat pump thermostat The worn out compressor capacitor could definitely explain the no heat in the heat pump mode condition and possibly a hot compressor at the same time but does not explain any burning smells followed by no heat conditions. All electrical components connections wiring and etc all appears normal in the water furnace envision package system Installed
New construction South 5 ton 2 zoned split hybrid dual fuel Geothermal mechanicals are running in good condition in heat pump multi-stage and cooling multi-stage 0 diagnostic service codes upon arrival today Ice is noticeable on both inlet and discharge lines around the non-insulated fittings at the wall and at the split Geo. Frost is also noticeable on the surface of the coax heat exchanger First floor thermostat (vision pro 8000 setup for two stage geothermal and two-stage gas heat) is at the set point of 68 however the basement T4 thermostat is reading 67 and set to 71 in heat mode Drywall in the basement is not complete causing the hot air to be drawn straight from the ceiling to the return in the ceiling and not satisfying the basement thermostat At the same time the T4110 thermostat (basement zone 2) will never energize second stage heating or cooling if zone 1 is not already running in second stage Re-insulate geothermal ground loop lines Return all equipment to thermos
Performed cooling maintenance on geothermal packaged heat pump system: Filter good Air coil clean Blower wheel clean Put Condensate drain treatment tablets in the coil pan Primed the drain trap with water No condensate leaks found, drain flowing properly Compressor amps 21, rated 27 Capacitor 42mfd (under load), rated 40mfd Strapped reversing valve wiring off the bare copper TXV line to prevent a short circuit due to mechanical vibration Blower motor amps 2.2, rated 7.0 under full load No visual signs of internal water or refrigerant leaks No overheated wiring All electrical connections secure and tight Geo loop circulation pumps 1.8 amps, rated 2.14 total Domestic hot water generator functioning normally Zone dampers opening and closing properly System is in good working order at this time.
Outdoor unit of first floor system not running Discovered rodents nesting in the electrical compartment of the outdoor unit. Damaged control voltage wiring is the cause of the no operation outside Visual inspection of indoor evaporator A coil and air filter during pre-inspection Clean and disinfect the electrical compartment Repair damaged wiring Water flush condenser coils on both air conditioners Add rodent poison provided by homeowners to the electrical compartment of both outdoor air conditioners Cooling run test from first floor nest thermostat
Water for a 7 series 3 ton equipment is running an excellent condition at this time. Preseason cooling preventive maintenance inspection & cleaning Scan computer for relevant service codes and confirm hot water generator operation Shop vac all equipment including filter rack and return air duct Run test all equipment in multi-stage cooling mode and confirm all functions are within specs Flush AC condensate drain Clear all cycle counters and return equipment to thermostat controls for normal heating operation Homeowner is interested in alternate methods of auxiliary heat operation to assist with the "undersized" geothermal equipment Daikin hp is the primary interest at this time. Seth will consult with JP and move forward in the appropriate manner
Replace 4' of 8x8 Ductwork in crawl space Install 1 - 4" crawl heat Re-Route 2 - 6" heat runs to sides of 8x8 ductwork Replace main trunk line in basement Install 8' of 16x8 ductwork Install 10'-12' of 14x8 ductwork Re-Route 6" & 7" heat runs (currently coming off end cap) to sides of new ductwork
Install Aprilaire 600M bypass humidifier. Humidifier is mounted on supply plenum, and bypass pipe run to return drop. Drain line is tied in fith furnace drain due to limited space in floor drain. Waterline is ran to hot waterline on wall behind furnace. Electric is ran into furnace and connected to thermostat for operation. Test ran humidifier from thermostat. Humidifier is operating properly. Instructed Brett on operation procedure and how to change humidifier pad. Flushed out hot water heater. Some calcium deposits were Flushed out, and no dirt or sediment deposits were witnessed.
Install New Daikin FIT HVAC System Heat Pump: DZ6VSA3010AB Serial #: 2305126449 Air Handler: DFVE36CP1400AA Serial #: 2302208202 HKSC10XC - 10 KW Heat Package Daikin One+ Thermostat: DTST-TOU-A Serial #: EA2304003502 * Reconnect to existing gas line and electric * Transition to existing supply and return ductwork * Start up and commission new system 12 Year Daikin manufacturers parts warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed) Lifetime Heat Exchanger Warranty (Annual maintenance must be performed) Aprilaire 1210 (20x25) Media Air Cleaner
Confirmed failed blower motor 208-230 indoor electric air handler 1/3 HP blower motor with 3 attached mounting legs Motor is in stock and available for installation at today's visit, $526.38 After discussions with Cathy homeowners have decided to proceed with replacement Daikin fit equipment
April there 500 bypass humidifier leaking water through the cover onto the floor of the mechanical room in the garage Homeowners recently replaced the number 10 evaporator pad however the replacement media was installed sideways allowing straight flow through of the water at the same time the feet or tube was not fully inserted into the upper distributor reservoir allowing water to flow out of the plastic drain pan Clean plastic shroud, replace number 10 pad homeowner's already had on site and run test, adjust water pressure down for less waste in the drain
Homeowner concerns our intermittent operation and temperature dropping. Thermostat always responds and turns on if temperature is adjusted up. Generation 1 vision pro 8000 touch screen. 2-stage heat one stage cool Upon arrival today the thermostat was at the set temperature and satisfied. System did cycle on and off multiple times under the thermostat normal control. Resurface flame sensor, inspect and blowout drain trap, test run equipment in multi-stage heat, maximum temperature on high heat reached 121°f Inspect thermostat wiring and AAA batteries. No low battery indicators and no corrosion. Duracells dated 2015
Performed maintenance on heatpump and gas furnace. Changed filter. Checked humidifier and ERV.