725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for powell, oh

Rated 4.9 out of 5 stars based on 17 customer reviews

Wonderful service

Great service, clean, and courteous. Very friendly. This was an annual check and a piece was broken. They had it on the truck and repaired it that day. Highly recommend.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very knowledgeable technician

Seth did a great job. He was very knowledgeable and quickly diagnosed our issue.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great, quick service

Great quick service, and did more than I even expected

  • Overall Experience
  • Quality
  • Price
  • Convenience

Repeat Customer for a reason

This is my second house that I am using Westin air for servicing, and not just annual HVAC inspections and cleaning. My first house only had one air vent in a large furnished basement. It caused problems. They added more circulation without touching the cosmetics. My 2nd house needs more circulation in the basement due to moisture in the summer. There air no water leaks in the walls to fix. Just stale, moist air forcing me to run the dehumidifier. Their pricing is reasonable for the work and the cost savings from the electric bill is worth it.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

All went well and to our satisfaction

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

The technicians quickly diagnosed the problem and fix our unit

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always helpful

  • Overall Experience
  • Quality
  • Price
  • Convenience

Pleasant and thorough.

Westin still has a 5 star rating with me, though the fact that Westin canceled out original appointment and was late on the rescheduled appointment puts that opinion in jepordy.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great price and installation

I'm very satisfied with Weston air. I complement their sales person who came to out home and the office person for her attention. The installation crew was excellent.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Thanks for sending Seth.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Timely service, good inspection and advise

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service! Seth is extremely friendly and easy to work with!

I am very pleased with our service from Westin Air. They are very accommodating to crazy schedules as well.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Westin Air is one of the most easy to deal with service company I have dealt with in a long time. From the front office staff to the service team everyone is friendly and professional and are very responsive to any question or concern I have had. They stand behind the products they represent and are very easy to deal with. I had a new HVAC system installed about a year ago and have had multiple issues within this time period. Seth my service tech came out and spent numerous hours diagnosing and eventually fixing the problem so I can defiantly say they stand behind the products.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Satisfied!

Seth arrived within the window and performed annual maintenance on two furnace units. He was courteous while in the home, performed his work timely and made sure to point out items that needed my attention. I have used Westin a number of times over the past year for various properties and have always felt they provided a good service that is reliable and honest. I would recommend Westin to anyone looking for service on their heating/air systems.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for powell, oh

Nate G.

Nate G. Job Checkin

Performed 3 system heating maintenance Master bedroom Mitsubishi ducted heat pump 20x20x1 filter is new today Cleared the drain from the outdoor outlet with shopvac Got in the attic and inspected air handler No signs of water leaks Outdoor coil is clean Run tested system in heat mode No concerns found with this system 2nd floor gad furnace 20x25x1 Filter is new Pulled and cleaned the flame sensor Condensate trap is clear Run tested furnace Gas pressure set to 3.0" Temperature rise is 45⁰ Blower is clean Furnace operating perfectly within manufacturer's specs Basement furnace 20x25x1 Filter is good Pulled and cleaned the flame sensor Condensate trap clear Run tested furnace Gas pressure set to 3.0" Temp rise 55 Blower clean Operating within manufacturer's specs No concerns found with all 3 systems, all are heating normally at this time


Graham M.

Graham M. Job Checkin

Upon arrival found furnace attempting to start but gas valve wasn’t opening. Valve was in off position. Turn valve on and test run furnace. Unit is heating with no problem now.


seth p.

seth p. Job Checkin

Climate Master tranquility 27 6-ton system pressurized alcohol closed loop Geo system Upon arrival the thermostat was set 2° below the actual room temperature in cooling mode and calling for stage 1. The zone control panel recognizes the cooling demand and engaged y1 on the geothermal package equipment. After multiple test runs and different procedures the CXM control board has failed and will not output a (Y)contactor 24vac signal. Hotwire run testing confirms both flow center pumps are functioning and cooling mode is running in very good condition on second stage with 54° supply temperature, 127\315 refrigerant pressures R410A Seth will prepare an estimate for a replacement CXM control board and repressurizing the geothermal antifreeze ground loops System is currently running in cooling mode with the CXM safety circuit contactor relay bypassed CC output wire is now on Y until repairs are completed 9-24-25 2:30p Seth has contacted the ClimateMaster local supplier and is awaitin


seth p.

seth p. Job Checkin

The noises heard on the outdoor heat pump by the homeowner were unable to be duplicated or replicated while on site today. The system was ramped up and down multiple times from off to maximum cool and several stages in between. Refrigerant pressures were tested perfect at 117 and 325 with 9sc and 17 superheat. Air filter is approximately 2 to 3 months old on schedule with homeowner and he will check and replace. Diking control does not indicate any service codes or caution indicators Recommend homeowner use system normally until the noise can be positively identified by a daikin service technician


Nate G.

Nate G. Job Checkin

Washed all 3 outdoor units Need to return to perform heating maintenance and finish up cooling maintenance, particularly the attic heat pump air handler for the master bedroom.


Nate G.

Nate G. Job Checkin

New belt installed a few weeks ago during preventative maintenance came apart This could just be a faulty belt or a sign that the pulleys need replaced. If this occurs again in a short period of time, we will quote to replace the blower and motor pulleys. Replaced belt System operating normally and sounding normal

New belt installed a few weeks ago during preventative maintenance came apart
This could just be a faulty belt or a sign that the pulleys need replaced.  
If this occurs again in a short period of time, we will quote to replace the blower and motor pulleys. 
Replaced belt
System operating normally and sounding normal

Graham M.

Graham M. Job Checkin

Install replacement non-pressurized flow center, including hose connection kit FC2-GLNP Reuse all existing antifreeze isolated in the ground loops during the repair service and top off the new reservoir with 4 gallons of new cryotech 100 resulting in a 10%-15% mixture with roughly 22-24° freeze protection. Water furnace equipment usually requires a 15 to 20° freeze protection antifreeze on closed loop systems. If equipment intermittently or repeatedly locks out on freeze protection a antifreeze flushing cart rejuvenation service may be required to achieve 15° freeze protection with propylene glycol Flush and bleed out all air pockets Run test cooling mode

Install replacement non-pressurized flow center, including hose connection kit
FC2-GLNP
 Reuse all existing antifreeze isolated in the ground loops during the repair service and top off the new reservoir with 4 gallons of new cryotech 100 resulting in a 10%-15% mixture with roughly 22-24° freeze protection.
Water furnace equipment usually requires a 15 to 20° freeze protection antifreeze on closed loop systems. If equipment intermittently or repeatedly locks out on freeze protection a antifreeze flushing cart rejuvenation service may be required to achieve 15° freeze protection with propylene glycol
Flush and bleed out all air pockets 
Run test cooling mode

Brandon P.

Brandon P. Job Checkin

Install WaterFurnace 5 Series Geothermal system. 2 Stage compressor, Variable Speed ECM blower -Model #NDV049K102NTL0BA Serial# 230202168 Efficiency: Up to 4.8 COP / 28.0 EER Features Included: *Aurora Base Controls *15KW Backup heat *2" Merv 11 air filter *GeoLink 2 pump non-pressurized loop flow center *Vision Pro 8000 WiFi thermostat Installation: *Install new 5 ton vertical loop field *Transition to existing supply and return duct Warranty: (Annual maintenance must be performed) Remainder of current WaterFurnace 10 Year Parts and 5 Year Labor Good through - 03/15/2028 for labor warranty & 03/15/2033 for Parts Warranty Flow Center and Accessories 5 Year Parts and Labor **30% Federal Tax Credit Eligible*** ***High voltage electric circuits to be done by others*** Disclaimer: No drill cuttings or water cleanup is included in price. No site restoration or seed and straw included in price. Westin Air will call OUPS for underground utility locates. All privately installed lines are


Install WaterFurnace 5 Series Geothermal system. 2 Stage compressor, Variable Speed ECM blower
-Model #NDV049K102NTL0BA
Serial# 230202168
Efficiency: Up to 4.8 COP / 28.0 EER
Features Included:
*Aurora Base Controls
*15KW Backup heat
*2" Merv 11 air filter
*GeoLink 2 pump non-pressurized loop flow center
*Vision Pro 8000 WiFi thermostat

Installation:
*Install new 5 ton vertical loop field
*Transition to existing supply and return duct

Warranty: (Annual maintenance must be performed)
Remainder of current WaterFurnace 10 Year Parts and 5 Year Labor 
Good through - 03/15/2028 for labor warranty & 03/15/2033 for Parts Warranty
Flow Center and Accessories 5 Year Parts and Labor

**30% Federal Tax Credit Eligible***
***High voltage electric circuits to be done by others***
Disclaimer: No drill cuttings or water cleanup is included in price. No site restoration or seed and straw included in price. Westin Air will call OUPS for underground utility locates. All privately installed lines are 
Install WaterFurnace 5 Series Geothermal system. 2 Stage compressor, Variable Speed ECM blower
-Model #NDV049K102NTL0BA
Serial# 230202168
Efficiency: Up to 4.8 COP / 28.0 EER
Features Included:
*Aurora Base Controls
*15KW Backup heat
*2" Merv 11 air filter
*GeoLink 2 pump non-pressurized loop flow center
*Vision Pro 8000 WiFi thermostat

Installation:
*Install new 5 ton vertical loop field
*Transition to existing supply and return duct

Warranty: (Annual maintenance must be performed)
Remainder of current WaterFurnace 10 Year Parts and 5 Year Labor 
Good through - 03/15/2028 for labor warranty & 03/15/2033 for Parts Warranty
Flow Center and Accessories 5 Year Parts and Labor

**30% Federal Tax Credit Eligible***
***High voltage electric circuits to be done by others***
Disclaimer: No drill cuttings or water cleanup is included in price. No site restoration or seed and straw included in price. Westin Air will call OUPS for underground utility locates. All privately installed lines are

Nate G.

Nate G. Job Checkin

Performed cooling maintenance on a 19yr old Ruud split system Changed 16x25x1 filter Put Condensate treatment in the evaporator coil drain pan Drain is not trapped, which is incorrect from time of installation Potential water overflow is a risk from not having a trap Store owner has never noticed water leaking Got on the roof Condenser coil is not in need of a cleaning R22 refrigerant charge appears to be starting to go low Low voltage control wire has UV sun damage Wrapped control wire with electrical tape to prevent wires from becoming bare and shorting out No complaints of the system not cooling properly in the hot months When it comes time to replace, recommend installing a heat pump to help with electric costs during heating season

Performed cooling maintenance on a 19yr old Ruud split system
Changed 16x25x1 filter
Put Condensate treatment in the evaporator coil drain pan
Drain is not trapped, which is incorrect from time of installation
Potential water overflow is a risk from not having a trap
Store owner has never noticed water leaking
Got on the roof 
Condenser coil is not in need of a cleaning
R22 refrigerant charge appears to be starting to go low
Low voltage control wire has UV sun damage
Wrapped control wire with electrical tape to prevent wires from becoming bare and shorting out

No complaints of the system not cooling properly in the hot months

When it comes time to replace, recommend installing a heat pump to help with electric costs during heating season Performed cooling maintenance on a 19yr old Ruud split system
Changed 16x25x1 filter
Put Condensate treatment in the evaporator coil drain pan
Drain is not trapped, which is incorrect from time of installation
Potential water overflow is a risk from not having a trap
Store owner has never noticed water leaking
Got on the roof 
Condenser coil is not in need of a cleaning
R22 refrigerant charge appears to be starting to go low
Low voltage control wire has UV sun damage
Wrapped control wire with electrical tape to prevent wires from becoming bare and shorting out

No complaints of the system not cooling properly in the hot months

When it comes time to replace, recommend installing a heat pump to help with electric costs during heating season

Jason D.

Jason D. Job Checkin

SOLD: 08/28/2025 10:07:15 AM - Option 1 Install new Bryant HVAC system Equipment: Furnace-926TC48080V17 Bryant, Preferred, 96" AFUE, Two Stage, 4-Way Multipoise, VCT ECM, Gas Furnace, 80K, 17" width Serial# 1825A63314 AC-GA4SAN53000N 13.4 SEER2 Single-Stage Air Conditioner with Puron Advance Refrigerant, R-454B, 2.5 Ton, 208/230 Volt, 1 Phase, 60 HZ, North Serial# 3025C24224 Coil- CVAVA3017XMAEAAA Serial# 2425J79524 *Honeywell T4 Pro thermostat Installation: *Install new PVC furnace vents *1" Standard filter rack *Reconnect to existing gas line and high voltage electric *Transition to existing supply and return ductwork *Start up and commission the new system Warranty: 10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed)


SOLD: 08/28/2025 10:07:15 AM - Option 1

Install new Bryant HVAC system

Equipment:
Furnace-926TC48080V17 Bryant, Preferred, 96" AFUE, Two Stage, 4-Way Multipoise, VCT ECM, Gas Furnace, 80K, 17" width
Serial# 1825A63314
AC-GA4SAN53000N 13.4 SEER2 Single-Stage Air Conditioner with Puron Advance Refrigerant, R-454B, 2.5 Ton, 208/230 Volt, 1 Phase, 60 HZ, North
Serial# 3025C24224
Coil- CVAVA3017XMAEAAA
Serial# 2425J79524
*Honeywell T4 Pro thermostat

Installation:
*Install new PVC furnace vents
*1" Standard filter rack
*Reconnect to existing gas line and high voltage electric
*Transition to existing supply and return ductwork
*Start up and commission the new system

Warranty:
10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed)
2 Year Westin Air labor warranty (Annual maintenance must be performed)



SOLD: 08/28/2025 10:07:15 AM - Option 1

Install new Bryant HVAC system

Equipment:
Furnace-926TC48080V17 Bryant, Preferred, 96" AFUE, Two Stage, 4-Way Multipoise, VCT ECM, Gas Furnace, 80K, 17" width
Serial# 1825A63314
AC-GA4SAN53000N 13.4 SEER2 Single-Stage Air Conditioner with Puron Advance Refrigerant, R-454B, 2.5 Ton, 208/230 Volt, 1 Phase, 60 HZ, North
Serial# 3025C24224
Coil- CVAVA3017XMAEAAA
Serial# 2425J79524
*Honeywell T4 Pro thermostat

Installation:
*Install new PVC furnace vents
*1" Standard filter rack
*Reconnect to existing gas line and high voltage electric
*Transition to existing supply and return ductwork
*Start up and commission the new system

Warranty:
10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed)
2 Year Westin Air labor warranty (Annual maintenance must be performed)

Graham M.

Graham M. Job Checkin

Perform cooling maintenance on 2 systems. Coils clean Test run cooling on each system Run capacitors within spec Delta T NE- 19° SW- 21° Units are in proper operation at this time.


Nate G.

Nate G. Job Checkin

Condenser coil 75% damaged due to what appears to be a power washer System running very high head pressure as a result Capacitor tested OK Cause for outdoor fan motor stopping is likely due to overheating from the damaged coil and the unit getting too hot System has a history of refrigerant leaks, service record on the ductwork from 2014 shows 1lb of r22 and leak sealant added Exhaust and intake are incorrectly pitched

Condenser coil 75% damaged due to what appears to be a power washer 
System running very high head pressure as a result
Capacitor tested OK
Cause for outdoor fan motor stopping is likely due to overheating from the damaged coil and the unit getting too hot
System has a history of refrigerant leaks, service record on the ductwork from 2014 shows 1lb of r22 and leak sealant added
Exhaust and intake are incorrectly pitched
Condenser coil 75% damaged due to what appears to be a power washer 
System running very high head pressure as a result
Capacitor tested OK
Cause for outdoor fan motor stopping is likely due to overheating from the damaged coil and the unit getting too hot
System has a history of refrigerant leaks, service record on the ductwork from 2014 shows 1lb of r22 and leak sealant added
Exhaust and intake are incorrectly pitched

seth p.

seth p. Job Checkin

Install Honeywell vision pro 8000, set up for two stage geothermal, programmable with automatic changeover, connect to home Wi-Fi and confirm operation. Homeowner is responsible for creating a Honeywell account and connecting to the system *** Due to unforeseen circumstances and age of the equipment the single pump cannot be replaced. During an attempt today the pump motor assembly came apart in pieces with the impeller seized in the housing of the flow center with a broken drive shaft. *** Recommend replacing the pressurized water furnace flow center with a two pump non-pressurized replacement NP2 fc2glnp or equivalent


Brandon P.

Brandon P. Job Checkin

2019 Trane high efficiency AC running in great condition. Electronic air filter cleaning. Tested operation. System is working and pulling correct power. Suspect that blub for green light has burned out. No corrective action needed. Indoor delta t of 19F with supply temp of 52F. Refrigerant pressures are within spec. High 275psi with 11F SC, low 115psi with 10F SH. Water flushed outdoor coils to remove dirt and debris. Outdoor fan motor and compressor are operating within specs. 40/5uf capacitor is new as of 8-17. System is operating properly, efficiently and ready for Summer.

2019 Trane high efficiency AC running in great condition. Electronic air filter cleaning. Tested operation. System is working and pulling correct power. Suspect that blub for green light has burned out. No corrective action needed. Indoor delta t of 19F with supply temp of 52F. Refrigerant pressures are within spec. High 275psi with 11F SC, low 115psi with 10F SH. Water flushed outdoor coils to remove dirt and debris. Outdoor fan motor and compressor are operating within specs. 40/5uf capacitor is new as of 8-17. System is operating properly, efficiently and ready for Summer.

Graham M.

Graham M. Job Checkin

Upon arrival inspected mini split heads and found 0° delta T inspected outdoor suction at 16psi while running. 115 ambient. Unit low on refrigerant. Perform leak search on all components and found leak on outdoor lineset. Have to cut out the line and repair. Quote approved for repair. Will return and zoomlock leaking lineset.