Repeat Customer for a reason

This is my second house that I am using Westin air for servicing, and not just annual HVAC inspections and cleaning. My first house only had one air vent in a large furnished basement. It caused problems. They added more circulation without touching the cosmetics. My 2nd house needs more circulation in the basement due to moisture in the summer. There air no water leaks in the walls to fix. Just stale, moist air forcing me to run the dehumidifier. Their pricing is reasonable for the work and the cost savings from the electric bill is worth it.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

All went well and to our satisfaction

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

The technicians quickly diagnosed the problem and fix our unit

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always helpful

  • Overall Experience
  • Quality
  • Price
  • Convenience

Pleasant and thorough.

Westin still has a 5 star rating with me, though the fact that Westin canceled out original appointment and was late on the rescheduled appointment puts that opinion in jepordy.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great price and installation

I'm very satisfied with Weston air. I complement their sales person who came to out home and the office person for her attention. The installation crew was excellent.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Thanks for sending Seth.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Timely service, good inspection and advise

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service! Seth is extremely friendly and easy to work with!

I am very pleased with our service from Westin Air. They are very accommodating to crazy schedules as well.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Westin Air is one of the most easy to deal with service company I have dealt with in a long time. From the front office staff to the service team everyone is friendly and professional and are very responsive to any question or concern I have had. They stand behind the products they represent and are very easy to deal with. I had a new HVAC system installed about a year ago and have had multiple issues within this time period. Seth my service tech came out and spent numerous hours diagnosing and eventually fixing the problem so I can defiantly say they stand behind the products.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Satisfied!

Seth arrived within the window and performed annual maintenance on two furnace units. He was courteous while in the home, performed his work timely and made sure to point out items that needed my attention. I have used Westin a number of times over the past year for various properties and have always felt they provided a good service that is reliable and honest. I would recommend Westin to anyone looking for service on their heating/air systems.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for powell, oh

seth p.

seth p. Job Checkin

2023 s9x2 4-ton train cooling system silver maintenance tune-up cleaning and safety inspection 4 in media filter is on schedule with homeowners and humidifier damper and control are already turned off. Homeowners concerns with water leaking from the humidifier at the end of the heating season will need to be addressed at the fall tune-up with the humidifier filter change and startup procedures. Test run vision pro 8000 Wi-Fi in multi-stage cooling Increase continuous fan speed and low stage cooling by one tap each. Continuous fan is now on tp3 low cooling is now on tp4 Run test all outdoor equipment, test and inspect compressor capacitor 440 volts at 35 UF, test run ECM condenser fan motor, run test refrigerant pressures and water flush condenser coil. All equipment is in excellent running condition and ready for summer.


Nate G.

Nate G. Job Checkin

Performed cooling maintenance on a Daikin Fit AC system 20x25x4 filter is good Blower clean Drain clear No signs of water leaks from furnace that may occur during heating season Modified condensate float safety switch wiring to the alarm terminal on the furnace board Bypassed duct mounted humidistat to give Daikin thermostat full control of the humidifier in the winter Showed where the humidity settings are in the app Washed outdoor unit Checked refrigerant charge All numbers are within manufacturer's specifications at this time


Graham M.

Graham M. Job Checkin

Upon arrival inspected ac unit and discovered compressor was not starting with hard start functioning. Could hear it amping out and not starting. Replaced hard start kit and turned system back on to test. Unit is operating with no issues after repairs were performed.


Graham M.

Graham M. Job Checkin

Upon arrival found unit would kick on but no compressor function. Check compressor capacitor and circuit read 0.0MFD Replaced with oem size 45+5 dual run capacitor and test ran unit. Pressures a little shy from full but homeowner only wants capacitor replaced. No further concerns at this time


Graham M.

Graham M. Job Checkin

Cooling preventative maintenance performed Check filter - aa216 new today Check coil for any buildup or debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD - 40+5 @ 39.01+4.92 Check OD fan Amp - 0.55 Check compressor Amp - 6.61 Verify pressures and HP-SC/LP-SH Delta T - 21° The Air handler and AC are in optimal running conditions.

Cooling preventative maintenance performed
Check filter - aa216 new today
Check coil for any buildup or debris in drain pan and flush with water
Set up thermometers
Rinse down outdoor coil with garden hose
Check capacitor MFD - 40+5 @ 39.01+4.92
Check OD fan Amp - 0.55
Check compressor Amp - 6.61
Verify pressures and HP-SC/LP-SH
Delta T - 21°
The Air handler and AC are in optimal running conditions.

Graham M.

Graham M. Job Checkin

Upon arrival found bad run capacitor swollen. Replaced with 45+5 and test ran unit. Condenser coil clean and refrigerant pressures at 8° subcool unit is in good running shape at this time.


Brandon P.

Brandon P. Job Checkin

cancelling heating PMI until the fall. zeroing out invoice


Nate G.

Nate G. Job Checkin

Second floor system: Condensate safety switch was tripped, suspect system froze up during the event in question Reset the wet switch sensor Adjusted airflow, temp drop across the evaporator was too high. It was running a 27⁰ delta, it is now running a 22⁰ delta Suspect either someone bumped the set point too low and forgot to adjust it back or the thermostat got stuck. Got in the attic and traced every inch of the thermostat wire to rule out rodent damage that could have caused a short circuit. No damage to the wiring was found. When adjusting the set point for cooling, we recommend no more than two degrees of change, especially in extreme hot weather and cold weather, as well. Cold outdoor Temps with excessive run time will cause freeze up of the evaporator coil. More than a 2⁰ swing in extreme hot weather will make the system run all day and never get the space down to set point until night time. If the system appears to be stuck on (room temperature is way below set point i


Jason D.

Jason D. Job Checkin

Install New Daikin FIT HVAC System *Two Stage - Variable Speed Furnace: Model #: DM80VC0603BNAD Serial #: 2308092344 60,000 BTU's - 80% AFUE *Variable Speed Air Conditioner: Model #: DX6VSS3010AB Serial #: 2406161843 2.5 Ton - 16.8 SEER2 - 9.9 EER2 *Matching Indoor Coil: Model #: CAPEA2422B4BA Serial #: 2407044941 *Daikin One+ Thermostat: DTST-TOU-A Serial #: EA2404018080 Installation: * Reconnect to existing gas line and electric * Transition to existing supply and return ductwork * Start up and commission new system * Aprilaire 1210 (20x25) Media Air Cleaner Warranty: 12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed) Daikin manufacturers Lifetime Heat Exchanger Warranty (Annual maintenance must be performed)

Install New Daikin FIT HVAC System
*Two Stage - Variable Speed Furnace:
Model #: DM80VC0603BNAD
Serial #: 2308092344
60,000 BTU's - 80% AFUE
*Variable Speed Air Conditioner:
Model #: DX6VSS3010AB
Serial #: 2406161843
2.5 Ton - 16.8 SEER2 - 9.9 EER2
*Matching Indoor Coil: 
Model #: CAPEA2422B4BA
Serial #: 2407044941
*Daikin One+ Thermostat: DTST-TOU-A
Serial #: EA2404018080

Installation:
* Reconnect to existing gas line and electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Aprilaire 1210 (20x25) Media Air Cleaner

Warranty:
12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
Daikin manufacturers Lifetime Heat Exchanger Warranty (Annual maintenance must be performed)

seth p.

seth p. Job Checkin

The following is a list of possible costs associated with the leak searching. You will only be billed one or the other service plus the original diagnostics trip charge Step 1 - electronically searching $175 (includes opening up system for full access electronic and visual oil leak searching) Step 2 - nitrogen pressure testing $461.58 Recover all remaining refrigerant, 500 PSI nitrogen pressure testing to identify the leak location. Repair costs and new refrigerant will be quoted after the current leaks are identified 6-3-25 Attic split system geothermal installed 6\2020 Full system disassembly for visual, UV, and electronic system scan. Equipment lost a total of 45 oz of refrigerant since the last recorded refrigerant charge or balance which was thenew install in June of 2020. A very minimal non-reliable alerts detected around both split system King valves however no visible leakage was detected with dye or micro leak gel while on site today. All other components of the equipm


Brandon P.

Brandon P. Job Checkin

2011 Bryant AC running in good condition. Trane Clean Effects pre-filter cleaned. Visual inspection of indoor coil. Flush drain pan and drain lines. Humidifier damper is closed. Run test unit in cooling mode from thermostat. Delta t of 19F with supply temp of 54F. Refrigerant pressures are within spec. 250psi with 9F SC, low 120psi with 12F SH. Outdoor coils are in clean condition. Outdoor fan motor and compressor are operating within specs. System is operating properly, efficiently and ready for Summer.


Graham M.

Graham M. Job Checkin

Cooling preventative maintenance performed Check filter - 16x25x1 advised lower mercury rating for future Check coil for any buildup or debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD - 34.56+4.63 Check OD fan Amp - 0.43 Check compressor Amp - 4.97 Verify pressures and HP-SC/LP-SH Delta T - 19° The Air handler and AC are in optimal running conditions.

Cooling preventative maintenance performed
Check filter - 16x25x1 advised lower mercury rating for future 
Check coil for any buildup or debris in drain pan and flush with water
Set up thermometers
Rinse down outdoor coil with garden hose
Check capacitor MFD - 34.56+4.63
Check OD fan Amp - 0.43
Check compressor Amp - 4.97
Verify pressures and HP-SC/LP-SH
Delta T - 19°
The Air handler and AC are in optimal running conditions.

seth p.

seth p. Job Checkin

2005 water furnace 5 series split system geothermal located in basement matched with tempstar upflow gas furnace located in the Attic servicing the second floor Equipment r410a refrigerant charge is very low but not cycling on low pressure safety switches. Equipment is running stable at 48 PSI suction and 175 with expected pressures to be at 125 and 300. Full system charge is approximately 7-8 pounds. Isis forming on the bottom 25% of the attic system horizontal a coil. Homeowners have chosen not to recharge the r410a refrigerant until the leak has been identified with electronic and/or nitrogen pressure testing at a later date scheduled by the office staff Recommend 2-3 hours for refrigerant recovery and nitrogen pressure testing if electronic testing is not successful Today's diagnostics trip charge has been rolled over into the leak search estimate


seth p.

seth p. Job Checkin

Construction warranty Shorted 24vac control voltage 3 amp fuse on ABC control board inside Water furnace 7 series basement package system Found and disabled miswired makeup air system Rewired communicating thermostat inside of air handler Replace fuse and test run all modes Confirm thermostat is online and functional ***Office staff will reschedule the remaining repairs Finish install of makeup air controls in the basement Finish flow center hose kid insulation kit Install all caps and seals on non pressurized flow center


seth p.

seth p. Job Checkin

2007 water furnace premier DC volt communications Upon arrival homeowner had power turned off due to the fact that the compressor will not turn off ever under any thermostat mode or setting. Initial inspections discovered welded closed contacts on the 40 amp two pole starting relay contactor. At the same time the ground loop pressure has lost all pressure to zero starting at 45 within one year. Replace two pole contactor and re-pressurize ground loops to 60 PSI. Maximum house water pressure. Run test cooling mode high stage at 47° supply temperature Homeowner will monitor hose kits and flow center for any ground loop pressure loss. Westin Air can service any and all equipment and antifreeze flushing necessities inside the house however any foundation penetrations and outside ground loop work will require the original installing contractor or a professional geothermal well drilling company Ground loop antifreeze has not been identified at this point