725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for sunbury, oh

Rated 5.0 out of 5 stars based on 15 customer reviews

Chris was great

Showed up in a timely manner and explained everything very well

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service Exceeds Expectations

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Very professional Strive for excellence

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome

5 star plus

  • Overall Experience
  • Quality
  • Price
  • Convenience

5 Stars all the Way!

Excellent customer service and a tremendous knowledge of anything HVAC.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Great job - thanks so much!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome Service!!

Seth and the guy with him were awesome!! They were super friendly and were very thorough in their explanation of what they were gonna do and when they were done, explained how to use the new humidifier with great detail!! The price was great too!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Preventive maintenance inspection

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

Seth was professional. Did excellent propane to gas conversions on three furnaces.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Alway pleasant and efficient

  • Overall Experience
  • Quality
  • Price
  • Convenience

Took lots of time to explain things, thank you!

I really appreciate Seth taking the time to explain things to me in a way I could understand. Very friendly and knowledgeable!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Replacement System-Furnace & Heat Pump

  • Overall Experience
  • Quality
  • Price
  • Convenience

New roof top furnace

They did a great job! Helpful and professional. Neat work and on time.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome Geothermal service

Quick, efficient and friendly service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for sunbury, oh

Nate G.

Nate G. Job Checkin

Trane heat pump reversing valve not switching to cooling mode Jumped R to O wires outside for testing purposes, unit switched to cooling mode correctly Found ecobee thermostat wired incorrectly for a heat pump with fossil fuel auxiliary furnace. Corrected wiring Run tested system Data tag calls for 8⁰ liquid line subcooling Actual measurement was 1.5⁰ Added 1lb of R410a Subcooling now 8⁰


Nate G.

Nate G. Job Checkin

Performed cooling maintenance on a Lennox AC Filter new Drain clear Blower clean Outdoor coil dirty Capacitor in spec 6⁰ subcool 18⁰ drop across evap coil Refrigerant charge is good per the chart inside the unit Took top off outdoor unit Washed Condenser coil from inside out with water Reassembled System operating within factory specs at this time


Brandon P.

Brandon P. Job Checkin

Installing AprilAire E100 Dehumidifier 1 Year Labor Warranty 5 Year Parts Warranty Flex ductwork tied in with return ducting, drain tied in with furnace/coil drain, power hooked into extension cord, control setup on dehu,dehumidifier itself. Set to 45% per homeowners request.


Brandon P.

Brandon P. Job Checkin

Upon arrival, system was off. Turn3d onto cooling mode so that outdoor unit would come on. Fan motor was very sluggish to come on and compressor did not run, only made a buzzing sound. Found that original 45/5 Dual run capacitor has failed and will need replaced. Parts are covered under warranty but labor is not. Installed new 45/5 dual run capacitor and test ran in cooling mode. No other issues found or suspected at this time.


Nate G.

Nate G. Job Checkin

Performed cooling maintenance System appears to have been installed by previous homeowner: Furnace is set on a wood frame. Air performance is in spec: 18⁰ drop and enthalpy change 7 Made a quick air balance to try to push more air upstairs Condensate on ductwork due to high humidity, recommend a dehumidifier set to 55% or lower Washed outdoor coil Bushes around unit need to be 16" away from the sides System overcharged with refrigerant, was running 23⁰ subcool, specification is 10⁰ +/-3⁰ Recovered refrigerant until it came down to 13⁰ System operating within specifications at this time.


Nate G.

Nate G. Job Checkin

System throwing communication fault along with installation error code Per service manual and troubleshooting steps the control boards need replaced

System throwing communication fault along with installation error code 
Per service manual and troubleshooting steps the control boards need replaced

seth p.

seth p. Job Checkin

2002 Florida heat pump geothermal downflow r22 System has an internally shorted refrigerant gas pump. Due to the age, 23 years old and obsolete r22 refrigerant there is no available repairs for this equipment the system needs replaced. Non-pressurized two pump flow center with alcohol antifreeze currently at 0.970 Recommend replacing downflow geothermal package equipment with 15 KW auxiliary and installing new NP series flow center Cathy Shankland 614-679-3928 will be your comfort advisor through the next several steps and will contact you shortly


seth p.

seth p. Job Checkin

X13 blower motor module failure. Rheem Ruud 240vac electric air handler with heat pump Install gentech brand 6207x constant torque blower motor set to speed one for fan and three for compressor Phone battery dead with flow signal Homeowners well settle the invoice via online Link Ashlea will follow up on Monday


Jason D.

Jason D. Job Checkin

Install New Bryant HVAC System Bryant Preferred 97 2-Stage Gas Furnace Model #: 927TA48080V17 Serial #: 2125A61749 80,000 BTU's - 97% AFUE Bryant Single-Stage Air Conditioner Model #: GA4SAN53600N Serial #: 2025C32888 3 Ton - 13.4 SEER2 - 11 EER2 Puron Advance Refrigerant, R-454B Matching Cased Coil: CVAVA3617XMA Serial #: 1325J79153 Installation: * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system * Honeywell T4 Pro Thermostat * 1" Standard Filter Rack Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

Install New Bryant HVAC System 
Bryant Preferred 97 2-Stage Gas Furnace
Model #: 927TA48080V17
Serial #: 2125A61749
80,000 BTU's - 97% AFUE
Bryant Single-Stage Air Conditioner
Model #: GA4SAN53600N
Serial #: 2025C32888
3 Ton - 13.4 SEER2 - 11 EER2
Puron Advance Refrigerant, R-454B
Matching Cased Coil: CVAVA3617XMA
Serial #: 1325J79153

Installation:
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Honeywell T4 Pro Thermostat
* 1" Standard Filter Rack

Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

Nate G.

Nate G. Job Checkin

Canceled due to working now


seth p.

seth p. Job Checkin

2009 Bryant United technologies package geothermal 50YDV072 6 Ton system is completely depleted of all refrigerant charge. Factory requires 156 Oz 9.75 lb of r410a. Unfortunately this system has lived a very difficult and hard life by having the compressor, the coax heat exchanger, and the evaporator coil all replaced at some point in time and records of refrigerant leaks dated back to 2014. Currently there is oil spray on the side of the compressor and dripping oil on the compressor discharge line indicating multiple leaks in different areas. Original Bryant zone system is obsolete with no repair parts available. Recommend completely deleting the zone system in the house with the replacement of the new equipment or upgrading to a fully communicating intellizone 2 with redesigned ductwork Under these conditions Western Air is unable to provide any further assistance with this equipment and recommends the geothermal package be replaced Cathy Shankland, will be in contact ASAP 614


seth p.

seth p. Job Checkin

Upon arrival and initial inspection the air conditioner communications demand was interrupted and shut down by consolidated electric energy co-op system. The shutdowns were confirmed by the homeowner on the phone. At the same time the condenser capacitor had a failed compressor terminal. After bypassing past the electric company shut down for a test run the compressor failed to start but the fan motor ran Install replacement 370 volt power supply 35 + 5


seth p.

seth p. Job Checkin

2001 water furnace r22 P056 Downflow, Non-pressurized flow center equipment ALL 3/4PVC Confirm compressor burnout. Two of the three leads are shorted to ground causing an instant breaker trip with a call for compressor operation Compressor was already replaced once with a 2018 serial number Repair parts are obsolete for r22 equipment at 24 years old Disabled compressor and reset breaker. Fan motor will run and circulate air through the house however no compressor operation will occur Downflow package geothermal system needs replaced Cathy Shankland will follow up with homeowners Seth will upload all information and consult with Cathy


seth p.

seth p. Job Checkin

2022 Lenox 10 seer 3 ton r410a cooling system preventive maintenance inspection, tune up, and cleaning Replace 16x25x1 air filter already on site and perform minor modifications to the very tight filter slot, visually inspect evaporator coil, clean and flush evaporator drain pan and drain lines with p-trap, run test single stage cooling at 53° f supply temperature. Test run all equipment and cooling mode on the outdoor unit, inspect 370 vac power supply and starting relay. Water flush condenser coil and run test refrigerant pressures 129 and 369 with 15 subcooling and 17 superheat All equipment is clean safe and ready for summer Homeowner will reset the 66° test temperature on the thermostat


Graham M.

Graham M. Job Checkin

Cooling preventative maintenance performed Check filter - 20x25x1 change soon Check coil for any buildup debris in drain pan and flush with water Set up thermometers Check capacitor MFD - 43.68+5.02 Check OD fan Amp - 0.68 Check compressor Amp - 9.25 Verify pressures and HP-SC/LP-SH Delta T - 20° The Air handler and AC are in optimal running conditions. Cooling preventative maintenance performed Check filter -20x25x1 due soon Check coil for any buildup debris in drain pan and flush with water Set up thermometers Verify pressures and HP-SC/LP-SH Delta T - 18° The Air handler and AC are in optimal running conditions.

Cooling preventative maintenance performed
Check filter - 20x25x1 change soon
Check coil for any buildup debris in drain pan and flush with water
Set up thermometers
Check capacitor MFD - 43.68+5.02
Check OD fan Amp - 0.68
Check compressor Amp - 9.25
Verify pressures and HP-SC/LP-SH
Delta T - 20°
The Air handler and AC are in optimal running conditions.

Cooling preventative maintenance performed
Check filter -20x25x1 due soon
Check coil for any buildup debris in drain pan and flush with water
Set up thermometers
Verify pressures and HP-SC/LP-SH
Delta T - 18°
The Air handler and AC are in optimal running conditions.