Showed up in a timely manner and explained everything very well
Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.
Excellent customer service and a tremendous knowledge of anything HVAC.
Seth and the guy with him were awesome!! They were super friendly and were very thorough in their explanation of what they were gonna do and when they were done, explained how to use the new humidifier with great detail!! The price was great too!!
Seth was professional. Did excellent propane to gas conversions on three furnaces.
I really appreciate Seth taking the time to explain things to me in a way I could understand. Very friendly and knowledgeable!
They did a great job! Helpful and professional. Neat work and on time.
Cooling preventative maintenance performed Check filter -20x25x4 clean Check coil for any buildup debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD -45+5 @ 42.31+2.61 old - new today Check OD fan Amp - 0.92 Check compressor Amp - 8.31 Verify pressures and HP-SC/LP-SH Delta T - 18° The Air handler and AC are in optimal running conditions.
Performed cooling checkup System is from 1993 Set blower speed on the new furnace to match the capacity of the AC unit Refrigerant charge is OK Unit is electrically OK Producing 19⁰ temperature drop Despite age, system is working OK at this time.
Performed cooling maintenance on a Lennox AC system Filter is good Provided a 20x25x1 Filter that's included with the gold maintenance plan Drain is clear Blower is clean UV light is functional Tore down and washed outdoor unit Capacitor in spec Wiring is secure and free of damaged insulation Connected air probes to ductwork and refrigeration probes to outdoor unit Compared readings to the unit charging chart Verified indoor coil has a TXV metering device System was running 0.8⁰ subcooling after being cleaned. Per the chart at 85⁰ outdoor, we should have 4⁰ subcooling Got authorization to add R410a refrigerant Topped off system charge to achieve 4⁰ subcool System is operating well within manufacturer's specifications at this time
System locking out with no apparent reason. After checking multiple parts including but not limited to contactor, pressure switches, and incoming low and high voltage, control board is found to be faulty. 60uf capacitor is also reading low at 55uf. Replaced capacitor for testing to see if that was the issue with no improvement. Called for parts and availability from supply house with no answer. Left a voice mail but will have to call back for quoting. System is non operational at this time. Fan will still operate and can be used but cooling nor geothermal heating will operate.
OEM ADP brand exact match air coil drain pan Replace coil drain pan in the air handler while in place. No refrigerant service required 2025 spring AC maintenance All indoor equipment is in excellent condition after today's service blower is set to single speed, capacitor is good, drain trap was removed for services and repairs today and redesigned with new material. Raise and level the outdoor condenser. Water flush condenser coils, test outdoor capacitor and starting relay, run test cooling mode refrigerant pressures 120 with 3° superheat, 246 w/ 2° subcooling Indoor supply temperature is 56 Replace air filter the homeowner already had on site. All equipment is in very good condition and ready for summer
No cooling call on a 2 year old Lennox AC Compressor not starting Capacitor tests good (45mfd) Ohm'd compressor windings, readings are good Put a hard start kit on, Compressor fired up Took hard start off, Compressor now starts normally Explained compressor could be starting to fail (way prematurely) Threw out the idea of putting in a heat pump (if the Compressor dies) and making it a dual fuel system to save on propane in the winter. Signed up for gold maintenance plan **we need to return asap to perform maintenance, the condenser coil is extremely dirty** 20x25x1 filter
2001 Yrane XB 2 ton original to the house system is running in fair to good condition considering the age. The furnace was serviced in October by Brandon with a replacement blower capacitor. Today's indoor services included a drain flush, cooling system run test with 55 supply temperature and minor safety inspection inside. The outdoor equipment is running in fair to good condition with the power supply perfectly on point at 34.9 and 3.9 spec'd at 35 + 4 +/- 6% Running refrigerant pressures are within temperature curve for a piston r22 coil with 83 outdoor and 71 indoor temperature The outdoor spiny fin condenser coil was matted over on all four sides and required a extra heavy duty water flush. Air filter is in acceptable condition and reinstalled. The thermostat is cooling properly with no concerns of the homeowner and batteries were replaced within a few months All equipment is clean safe and ready for summer
Performed cooling maintenance on a 2017 Lennox 13SEER AC Filter is OK, change in a month Blower is clean Drain is clear Outdoor coil required a wash, took top off and washed from inside out Capacitor in spec Wiring in good shape We were outside of the required conditions to check the refrigerant charge against the manufacturer's chart this morning. It may have leaked since the recharge we did last June. Keep an eye on it. The first signs of frost on the insulated refrigerant line and not keeping up with cooling, please shut it off and call us. The system was cooling well today, but it is a very low heat load, currently. Everything else looks OK today.
Disassemble Armstrong air package equipment as far as necessary to remove drain pan and replace. Install new drain trap and drain trap pipe. Shop-Vac and foaming no rinse chemical clean evaporator coil No refrigerant service required as originally estimated. Bill was adjusted from $978 to $675 Notes: The entire RTU system is installed sloping away from drain pan termination. Installing a new drain pan will not fix this issue.
Performed cooling maintenance on two Trane heat pumps Furnace filters are still good, especially the second floor one Checked furnaces for condensate leaks - No concerns Blowers are clean Drains are clear Reset filter reminder on downstairs thermostat Checked outdoor units Coils are clean Refrigerant charges are correct Capacitors are within tolerance, downstairs unit is at the bottom end of the specification but no need to replace it yet... we will see if there's any deviation next year. No damage to wiring, all connections are secure Adjusted the downstairs outdoor TXV sensing bulb tubing to keep it from rubbing the suction line and wearing thin to the point of a leak. No major concerns found on today's visit.
Performed cooling maintenance on a Daikin Fit heat pump and Trane XR air conditioner. Put drain treatment in the daikin indoor coil drain pan to prevent drain clogging up Modified float switch wiring to throw a fault code display on the stat vs make the stat go blank in the event of a drain backup Adjusted heat pump lockout settings to enable the heat pump to run down to 10⁰ in an effort to save electric consumption in the winter. Filter is good. Outdoor coil is clean Refrigerant charge in spec No stored fault codes Trane system filter is new. Closed humidifier bypass damper Drain is clear Blower is clean Washed outdoor coil Capacitor in spec Refrigerant charge in spec Inspected furnace for water leaks that may have developed between maintenance visits No concerns found on this visit.
Install New Daikin FIT HVAC System *Two Stage - Variable Speed Furnace: Model #: DM96VC1005CNAB Serial #: 2406095939 100,000 BTU's - 96% AFUE *Variable Speed Air Conditioner: Model #: DX17VSS421BA Serial #: E004204 3.5 Ton - 16.6 SEER2 *Matching Indoor Coil: Model #: CAPE4860D4 Serial #: 2408160255 *Daikin One+ Thermostat: DTST-TOU-A Serial #: EA2410608041 Installation: * Reconnect to existing gas line and electric * Transition to existing supply and return ductwork * Start up and commission new system * Aprilaire 1210 (20x25) Media Air Cleaner Warranty: 12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed) Daikin manufacturers Lifetime Heat Exchanger Warranty (Annual maintenance must be performed)
Cooling preventative maintenance performed basement Check filter - 16x25x1 new today Gold Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD - N/A variable speed DC Control board / wiring - no concerns Verify pressures and HP-SC/LP-SH 212-5°/101-14° Delta T - 19° The Air handler and AC are in optimal running conditions. Cooling preventative maintenance performed attic Check filter - 16x25x1 new today gold Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD - N/A variable speed DC Verify pressures and HP-SC/LP-SH 198-7°/99-12° Delta T - 17° The Air handler and AC are in optimal running conditions.
Perform cooling maintenance on 1 mistubisi 3 headed system. Flush drains for each head, wash filters on each head. Turn on all units and check operation, each unit properly cooling at full demand.