Showed up in a timely manner and explained everything very well
Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.
Excellent customer service and a tremendous knowledge of anything HVAC.
Seth and the guy with him were awesome!! They were super friendly and were very thorough in their explanation of what they were gonna do and when they were done, explained how to use the new humidifier with great detail!! The price was great too!!
Seth was professional. Did excellent propane to gas conversions on three furnaces.
I really appreciate Seth taking the time to explain things to me in a way I could understand. Very friendly and knowledgeable!
They did a great job! Helpful and professional. Neat work and on time.
Install New Bryant 2 Stage Gas Furnace Model #: 926TC60080V21 Serial #: 5024A43517 * Reconnect to existing gas line and electric * Transition to existing supply and return ductwork * Start up and commission new system 10 Year Bryant Manufacturers Parts Warranty (Annual Maintenance Must Be Performed) 20 Year Heat Exchanger Warranty (Annual Maintenance Must Be Performed) 2 Year Westin Air labor warranty (Annual Maintenance Must Be Performed) * Honeywell T6 Pro Thermostat * Aprilaire 1210 Media Air Cleaner
Front of house system heat exchanger is rusted through. This is a quote to replace the heat exchanger and associated components. Both units are 6 ton and 12 years old.
Replace Bosch OEM ECM blower motor and module. Test run in fan only and heat pump heating. System is properly operating at this time with bo issues suspected.
Carrier Infinity thermostat locking out gas heat on service codes 13 and 33 Furnace inspection found locked out flame roll out switch on the right hand side of the direct vent enclosed burner box After reset and run testing rotten burners were found to be the cause of an overheated burner box. The fire is not going into the heat exchanger tubes as it should Replace all four burners and shop vac equipment. Shop-Vac and clean upper portion of heat exchanger. Run test gas heat at 121 Run test heat pump and found no condenser fan operation Install replacement 45 + 5 dual run capacitor 440 volt power supply Infiniti heat pump test supply temperature 101
Install r22 high pressure safety switch kit and perform refrigerant service to remove and seal off failed high pressure switch
Minor two system inspection for high electric bills. Water furnace 5 series equipment is running in excellent condition at this time. System has zero service codes since the last inspection. Test run equipment in heat pump mode and HP2 +aux and confirm all amp and volt readings for the heat pump and auxiliary on the south system. Turn off 5 kilowatts of the 15 KW heat strip pack at the breaker in the main panel Inspect vision pro 8000 installation and make minor adjustments to the multi-staging differentials. North system geothermal does not have any auxiliary heat and no other complaints by homeowner at this time. Water to water geothermal has failed at some point in the past and been replaced with a 4500 watt electric water heater to supply the radiant floor heat Equipment seems to be running in very good condition at this time. Recommend homeowner researching the budget price and kilowatt usage for electric over a long period of time for comparison
Trane recommends installing the stainless steel burner kit when converting the furnace to propane. The standard burners are notorious for rusting and causing ignition issues. Also replaced the burner orifices to fresh ones.
Service warranty Water in the pressure switch hose causing service code 2 red blonks The most probable cause is not priming the trap after cleaning last night. The hose did have a belly trap holding water before trimming shorter today Test vacuum at 2.4, switch activates at 1.7 System is running again Test run several times before departure Homeowners are aware of that diagnostic LEDs for future reference
Per homeowner description of the problem, the exhaust motor would run but nothing else would happen. After morning appointments he returned home and the temperature was 58. System was turned off and front cover doors were off upon arrival today Philco /Nordyne 90+ system turned on in fired off after the initial inspection and ran like normal. Resurface flame sensor and blowout drain trap Temperature rise is exceeding the recommended 45 to 75 and reaching 80°+ at 150 supply temperature with 69 return The exhaust pipe drain trap has a broken nipple that was reattached and resealed today. The exhaust motor has chirps and rattles that come and go that are not normal. Cleaning and lubrication of the motor and bearings made no difference to the sound. Visual inspection through the exhaust pipe rubber transition boot confirmed nothing visible or large enough to lodge itself in the motor housing. Gas valve does not have any manifold adjustments for pressure and blower assembly is already s
Diagnosis of bad blower motor module. Confirmed proper high and low voltage to blower motor module. After removing and inspecting module, found that one capacitor has failed and leaking fluid. After calling multiple local dealers that used to carry Bosch parts to find out they do not carry them anymore, Justin attempted to contact Bosch directly and was put on hold. Took plenty of pictures of motor module to assist in finding ine from Bosch, or possibly cross referencing from a different brand. Will have to call back once more info is sorted.
Two Carrier rooftop gas fired units. Front of house required a new belt. System was locking out on successive limit trips due to insufficient airflow from the worn out belt. This unit is in need of a new heat exchanger and inducer. Extremely rusted out and has pin holes. Back of house unit had the gas valve shut off internal to the unit. Heat exchanger is in OK condition for now, but will need replaced in the near future.
Normal operation blower speed separation multiple fins have let loose in the whole wheel is vibrating the entire furnace Install matching replacement blower wheel from warehouse stock and run test equipment in fan speed and heat mode Minor adjustments to motor mounting bracket and shaft position due to differences in blower wheel hub design. All equipment is running an excellent condition at 45 temperature rise
Oem furnace control board is failing. Inducer motor control relay is working intermittently and has the same symptoms as a frozen flue pipe. Replaced with universal integrated furnace control module, program for furnace, and test run in heating. System is properly operating with no other issues suspected.