Local Reviews
for sunbury, oh

Rated 5.0 out of 5 stars based on 15 customer reviews

Chris was great

Showed up in a timely manner and explained everything very well

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service Exceeds Expectations

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Very professional Strive for excellence

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome

5 star plus

  • Overall Experience
  • Quality
  • Price
  • Convenience

5 Stars all the Way!

Excellent customer service and a tremendous knowledge of anything HVAC.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Great job - thanks so much!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome Service!!

Seth and the guy with him were awesome!! They were super friendly and were very thorough in their explanation of what they were gonna do and when they were done, explained how to use the new humidifier with great detail!! The price was great too!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Preventive maintenance inspection

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

Seth was professional. Did excellent propane to gas conversions on three furnaces.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Alway pleasant and efficient

  • Overall Experience
  • Quality
  • Price
  • Convenience

Took lots of time to explain things, thank you!

I really appreciate Seth taking the time to explain things to me in a way I could understand. Very friendly and knowledgeable!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Replacement System-Furnace & Heat Pump

  • Overall Experience
  • Quality
  • Price
  • Convenience

New roof top furnace

They did a great job! Helpful and professional. Neat work and on time.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome Geothermal service

Quick, efficient and friendly service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for sunbury, oh

Nate G.

Nate G. Job Checkin

Concentric intake/exhaust termination kit installed incorrectly so the exhaust was being directed back towards the house. Large gaps present in the J block around the pipes. Put thumb gum putty around the pipes and installed termination kit in the correct orientation.


Nate G.

Nate G. Job Checkin

Removed 5 min compressor delay, set to 0 (defrost board has its own short cycle protection) Changed furnace lockout to 45⁰ Changed HP lockout to 25⁰ Set 2⁰ droop Left 5hr upstage timer Heat pump ran the entire time I had the thermostat in test mode


Nate G.

Nate G. Job Checkin

Performed heating maintenance on an 'aquatherm' style ADP air handler Flushed hot water tank Checked blower capacitor Replaced 12x20x1 filter AC evaporator coil clean Blower wheel clean Hot water coil clean Controls operating properly on the air handler (blower thermostat for water temperature) Electrical connections are secure and show no signs of overheating 0ppm carbon monoxide present around the water heater No gas leaks detected No water leaks present System operating normally at this time Renewed silver maintenance with monthly payment option


Jason D.

Jason D. Job Checkin

Replacement Warranty


Jason D.

Jason D. Job Checkin

SOLD: 02/16/2026 10:40:29 AM - Option 2 Install New Bryant Two Stage Gas Furnace Model #: 927TA48080V17A-A Serial #: 2525A60012 *Propane Conversion Kit 80,000 BTU’s - 97% AFUE Installation: * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system * Honeywell P200 Thermostat Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)


SOLD: 02/16/2026 10:40:29 AM - Option 2

Install New Bryant Two Stage Gas Furnace
Model #: 927TA48080V17A-A
Serial #: 2525A60012
*Propane Conversion Kit
80,000 BTU’s - 97% AFUE
 
Installation:
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Honeywell P200 Thermostat

 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

SOLD: 02/16/2026 10:40:29 AM - Option 2

Install New Bryant Two Stage Gas Furnace
Model #: 927TA48080V17A-A
Serial #: 2525A60012
*Propane Conversion Kit
80,000 BTU’s - 97% AFUE
 
Installation:
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Honeywell P200 Thermostat

 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

Brandon P.

Brandon P. Job Checkin

Replace failed control board with new oem control board from Waterfurnace. Test run operation of geothermal heating, aswell as axillary heat strips. No other issues found or suspected during testing.


Brandon P.

Brandon P. Job Checkin

Install flow center pump add on to take over for current failed flow center pump. Repressurize to 60psi from house water. Test run operation of pump, aswell as speed 9 heating as per manufacturer testing guidelines. No other issues were found during testing.

Install flow center pump add on to take over for current failed flow center pump. Repressurize to 60psi from house water. Test run operation of pump, aswell as speed 9 heating as per manufacturer testing guidelines. No other issues were found during testing.

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 16x25x1 ok - due soon Clean flame sensor Inspect burners - no concerns Ohm test igniter: 56.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 7.5mfd @ 7.23 Check amp draw on inducer motor:0.72 Check delta T - 56 Furnace is in optimal running conditions


Brandon P.

Brandon P. Job Checkin

Control board has failed and is not outputting a signal to the Y terminal for compressor operation. Confirmed control board issue with Waterfurnace. Control board will be ordered and will call to schedule repair once parts are in hand.


Brandon P.

Brandon P. Job Checkin

Upon arrival, system was in the off mode with fan on. Attatched pressure and temperature guages to perform an operation test. During heat pump operation testing, found that the heap pump is operating properly and refrigerant pressures and temperatures are within spec based on third party measurequick testing application. Jodi says that there has been no refrigerant added to her knowledge. Based on the operation measurements of the refrigerant and air temperature rise, the system is within refrigerant specifications and there is no leak search that needs to be performed. Tested operation of auxiliary heat strips and found no issues. Found that the thermostat heat pump lockout was set to 35F. With an all electric system, disabling the heat pump lockout temperature is recommended as the heat pump is still producing heat at those temperatures and the system is designed to run the auxiliary heat as needed to boost heat content, aswell as run the auxiliary during defrost mode which can happe


Brandon P.

Brandon P. Job Checkin

Inspection of all electrical systems. Could not recreate issue of heating stuck on while on site. Suspect it could be a bad control board with intermittent relay sticking. Will prepare a quote for control board replacement.

Inspection of all electrical systems. Could not recreate issue of heating stuck on while on site. Suspect it could be a bad control board with intermittent relay sticking. Will prepare a quote for control board replacement. Inspection of all electrical systems. Could not recreate issue of heating stuck on while on site. Suspect it could be a bad control board with intermittent relay sticking. Will prepare a quote for control board replacement.

Brandon P.

Brandon P. Job Checkin

Replace failed ABC control board with new oem ABC board and test run operation. No other issues found or suspected during testing.


Brandon P.

Brandon P. Job Checkin

Replace Waterfurnace HWG desuperheater coax coil. Part is covered under Waterfurnace Parts warranty. Labor and refrigerant is not. Remove and replace failed desuperheater water coil. Pressure test with nitrogen at 400psi for 10 minutes. Vacuum down to 500 microns and let sit for 30 minutes for decay test. Charge in 93oz of new R-410A. Installed new ABC board aswell and preformed test run. Refrigerant pressures are within spec. No other issues found or suspected.


Nate G.

Nate G. Job Checkin

Replace ECM blower motor with universal motor Converted from constant airflow to constant torque motor Blower was intermittently starting and stopping Couldn't determine if it was the board or the motor causing the issue. Switching to constant torque eliminated both possibilities


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a 2020 Lennox 96% efficient single stage natural gas furnace 16x25x1 filter is in good shape, looks almost brand new (using the correct MERV8 rating filter, please continue to use these same filters) Blower wheel is a touch dirty, at this point it doesn't seem to be causing system performance issues. Pulled and cleaned the flame sensor Condensate trap is clear Checked internal condensate lines for blockage Intake air screen free or debris Intake and exhaust pipes showing no signs of leakage at fitting glue joints Burners in good shape Run tested furnace Gas pressure set to 3.5"wc with reference to the sealed burner box Increased blower speed Temperature rise is a steady 62⁰ (spec is 35-65⁰) No signs of water leaks internal or external to the furnace 0ppm carbon monoxide present No concerns found on today's visit Furnace operating within factory specifications at this time