Showed up in a timely manner and explained everything very well
Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.
Excellent customer service and a tremendous knowledge of anything HVAC.
Seth and the guy with him were awesome!! They were super friendly and were very thorough in their explanation of what they were gonna do and when they were done, explained how to use the new humidifier with great detail!! The price was great too!!
Seth was professional. Did excellent propane to gas conversions on three furnaces.
I really appreciate Seth taking the time to explain things to me in a way I could understand. Very friendly and knowledgeable!
They did a great job! Helpful and professional. Neat work and on time.
Performed 5 system cooling maintenance Changed all filters. Westin provided (4) 20x20x2 filters for the large unit. The rest were supplied by the VFW. Smaller unit servicing the pool table area has NO provision for installing a filter. Considering age (9yrs) and never having a filter, the indoor coil is in OK condition. Checked refrigerant charge on the 3 split systems The old unit is not running ideal numbers but still cooling. If it fails to keep up, replacement will be necessary. Washed Condenser coils. Used duct mastic to seal as much of the outdoor portion ductwork for the big bar area unit. Got in the attic to survey the ductwork for that system There appears to be abandoned ductwork for an entire system that no longer exists and the heat runs and returns have been tied into the big unit's ductwork. Solving the duct deficiencies will be a massive undertaking. Discussed adding two 24k btu mini split systems to the bar area to supplement the cooling on hot/busy days. Dan want
Job is complete at this time. Incoming propane pressures was low at 10.5 furnace calls for 11"h20. I informed the homeowner to have propane company increase it. Everything is running good at this time
Reconnected drain line on the back side of the indoor head
Went over options for helping the ducted AC system Proposed adding dampers to the lower level heat runs and adding 3 more heat runs to the upper area Requested quote for new mini split, ok with two single zone units Currently is 18,000 with two 12,000 indoors.
Upon arrival, system was in cooling mode but set high enough that it would not attempt to run. Little spot of water in the attic upon first inspection. Could not find anything around the perimeter of the indoor coil that looked like water spots. Turned on AC to test run operation and see if any leaks were visible. Inspection around attic portion showed no external leaks. Inspected drain line termination at outside near condenser unit and there was no condensation dripping. Suspected drain line to be clogged. Used gallow gun to blow through drain line. Slight pressure build up at first, followed by an audible popping noise, and then water started to flow out of the drain. Initial water was chunky and murky, and gradually got cleaner. Inspected attic portion again and found no leaks. System is properly draining and ready for operation.
SOLD: 08/20/2025 9:29:32 AM - Option 3 Install new Bryant HVAC system Equipment: Furnace-926TC66100V21 Preferred, 96" AFUE, Two Stage, 4-Way Multipoise, VCT ECM, Gas Furnace, 100K, 21" width Serial# 1825A58730 AC-GA5SAN54200W 14.3 SEER2 Single-Stage Air Conditioner with Puron Advance Refrigerant, R-454B, 3.5 Ton, 208/230 Volt Serial# 3025G04973 Coil- CVAVA4221XMAEAAA Serial# 1725J6352 *Honeywell Vision Pro 8000 thermostat *AprilAire 1210 High efficiency media air cleaner *LP conversion kit Installation: *Reconnect to existing gas line and high voltage electric *Transition to existing supply and return ductwork *Install new PVC furnace venting *Start up and commission the new system Warranty: 10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed)
2009 carrier 13 seer 2.5 ton r410a equipment is running in very good condition after maintenance cleaning and cooling system service perform today Taking into consideration the homeowners concerns of long run times to achieve the temperature in summer the evaporator coil was visually inspected, the drain trap was flushed & scrubbed, and maximum speed blower was confirmed. The air filter is acceptable and on schedule with homeowner. Evaporator coil inspection reveals light buildup that is not a concern today. Future coil cleanings can be performed but are not really necessary at this point The outdoor equipment inspection revealed heavy buildup on 25% Plus of the condenser coil creating high head pressures and hot liquid temperatures. Heavy-duty water flush of the condenser coil resolved all issues outside and the refrigerant pressures are perfectly within specs stated on the outdoor equipment. The 370 volt power supply is slightly low but still within specs at 38.1 / 5.0 All equipmen
Split system off the front parking lot not running at all Diagnosed failed transformer on the furnace Replaced transformer System working normally at this time.
Service warranty. Internal drain trap hose disconnected from drain pan nipple causing water to drain into furnace cabinet. No electronics were touched by water. Attempted to remove as much water as possible. Told Greg that it was pure water as he had a gate up to keepcthe cat away, and that there was still a bit left and it would dry up on its own.
Performed cooling maintenance on a Goodman system 14x20x1 filter is OK, change after another month or two Blower OK Blower speed too high, bumped it down one speed lower from factory high setting Outdoor coil 50% plugged with pollen Removed top from unit, washed coil from inside-out Capacitor tested good Wiring in good shape Refrigerant charge OK System operating normally at this time
Service warranty no charge Minor electrical repair to high voltage metal conduit leading to compressor circuit of geothermal
Install New Bryant HVAC System Bryant Preferred 97 2-Stage, Variable 25-Speed Gas Furnace Model #: 927TA48080V17A Serial #: 4224A62315 80,000 BTU's - 97% AFUE Condensing Gas Furnace with InteliSense Technology Bryant Single-Stage Air Conditioner Model #: GA4SAN53000N Serial #: 0525C30787 2.5 Ton - 13.4 SEER2 Puron Advance Refrigerant, R-454B 208/230 Volt, 1 Phase AC Pad Matching Cased Coil: CVAVA3017XMA Serial #: 1525J52185 Installation: * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Reuse existing air filter rack * Start up and commission new system * Honeywell P200 thermostat Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
Performed cooling maintenance Indoor unit clean Drain flowing normally Checked outdoor unit Refrigerant numbers have not deviates from readings taken last year Capacitor tested 45/5mfd Tore apart outdoor unit and washed with coil cleaner System maintaining 66⁰ indoor temperature.