Showed up in a timely manner and explained everything very well
Overall Experience
Quality
Price
Convenience
Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Excellent customer service and a tremendous knowledge of anything HVAC.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Seth and the guy with him were awesome!! They were super friendly and were very thorough in their explanation of what they were gonna do and when they were done, explained how to use the new humidifier with great detail!! The price was great too!!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Seth was professional. Did excellent propane to gas conversions on three furnaces.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
I really appreciate Seth taking the time to explain things to me in a way I could understand. Very friendly and knowledgeable!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
They did a great job! Helpful and professional. Neat work and on time.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Performed heating maintenance on a Lennox 93% efficient single stage natural gas furnace Found water damage inside the furnace that is currently wet Verified water leak is from improper installation of the furnace condensate trap Cannot remove the trap without destroying it Need to install a brand new trap kit We will call Lennox in the morning to get price and availability then email over the price for the repair 16x25x1 filter is new Pulled and cleaned the flame sensor Cleared condensate tubing internal to the furnace Run tested furnace Set gas pressure to 3.5"wc with reference to the sealed burner box Temperature rise 69⁰ (spec 45-75⁰) Furnace is operating within factory specifications at this time Only concern found is the water leak As stated above, we will call Lennox for part price and availability and email over the proposal in the morning
Two system heating maintenance Main house: Heat pump operating upon arrival 37⁰ temperature rise 150⁰ Vapor line temperature 106⁰ supply air Temperature Puller and cleaned the flame sensor Sensor rod is beginning to get pitted (common with propane use) No need to replace the flame rod yet, but will need done eventually Run tested furnace Manifold pressure set to 11.0"wc Temperature rise 62⁰ System operating within spec at this time House addition: Run tested heat pump After 10 minutes System produced: 34⁰ temp rise 135⁰ Vapor line temperature And 106⁰ supply air temp Pulled and cleaned flame sensor Flame rod is also pitting on this furnace, too Manifold pressure 11"wc Temperature rise rdhc65et⁰ System operating within spec at this time
Performed heating maintenance on a 2022 Bryant 95% efficient single stage natural gas furnace Replaced replaced the electronic air cleaner filter cartridge with the one we provide with the gold maintenance plan PGAPXCAR 20X20 Aprilaire 500 humidifier #10 water panel in good shape Bypass damper moved to open (winter) positiom Run tested humidifier to verify correct operation and no water leaks at this time Humidity set to 45% ***Decrease humidity setting if condensation forms on any windows, especially with cold outdoor temperatures** Pulled flame sensor and cleaned Condensate trap is clear Blower wheel in OK condition Burner Manifold gas pressure set to 3.0"wc Temperature rise stabilized @ 53⁰F (spec 40-70⁰) Furnace is operating within factory specifications at this time No concerns found on today's visit
Performed heating maintenance on a Trane 2 stage 96% efficient propane-fired furnace Pulled and cleaned flame sensor Checked Condensate lines Adjusted burner Manifold pressure also had to increase house regulator pressure to get burner pressure correct 10"wc high fire 6"wc low fire Temperature rise 35⁰ for both fire rates 16x25x1 filter is in OK condition Signed up for silver maintenance plan
Performed two system heating maintenance Attic system: 2023 Lennox dual fuel system Two stage 96% efficient LP-fired furnace 3 ton heat pump 16x25x1 filter is good Left a new one with the furnace Corrected drain safety switch wiring to shut the furnace and AC down in the event ofman drain backup Run tested heat pump Getting 110⁰ Vapor line temperature and 17⁰ temperature rise Pulled and cleaned furnace flame sensor Cleared condensate ports internal to the furnace Run tested furnace High fire Manifold pressure set to 10"wc with reference to the sealed burner box Temperature rise 40⁰ Low fire pressure set to 4.5" Temperature rise 30⁰ Main system: 2023 Lennox dual fuel system 18 SEER inverter heat pump 2 stage 96% propane furnace Ductwork massively undersized 5 ton heat pump requires 2000CFM of air Return drop is 10x24" with one side utilizing a 16x25x1 filter Return trunk is 8x24 Ductwork needs to be at least 30x12 with a 20x25x4 filter, preferably a 24x25x4 Discussed issue of airflo
Performed leak search on mini split of all flare fittings Found vapor line flare fitting on indoor head for the lobby Tightened flare. All other flare connections are good Next step will be recover refrigerant and reflare the line if tightening does not stop the leak
SOLD: 11/12/2025 9:47:28 PM - Option 1 Install New Bryant Two Stage Gas Furnace Model #: 927TA48080V17 Serial #: 4425A59611 80,000 BTU’s - 97% AFUE Installation: * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system * Air Filtration - AprilAire 1210 (20X25) Media Air Cleaner Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
Zone 1 dampers whistling when closed during zone 2 call for heat Discussed options Decided to lock zone 1 dampers open
Install WaterFurnace 5 Series Geothermal split system. 2 Stage compressor - Geothermal Model # W5SZ048BD1B1FCFFFB10 4 Ton 5 Series Split Geo Serial# 251000494 -Geothermal Coil Model # A5DC048BNFA0FFFFFF1F Serial# 251000495 - Furnace #Bryant 927TA60080V21 Preferred 97, Up to 97% AFUE, Two-Stage, Variable 25-Speed, Non-Communicating, 4-Way Multipoise, Condensing Gas Furnace with InteliSense Technology, 80K, 5T, 21" width Serial# 2025A45614 Features Included: *Aurora Advanced Controls *April Aire 1210 High Efficiency Media Air Cleaner *2 Pump GeoLink non-pressurized loop flow center *Vision Pro 8000 WiFi thermostat Installation: *Install 4 Ton vertical closed loop field (Installed by Jackson Geothermal) *Reconnect to existing high voltage electrical circuit *Add electrical circuit for Geo split portion *Transition to existing supply and return duct Warranty: (Annual maintenance must be performed) WaterFurnace 10 Year Parts WaterFurnace 5 Year Labor Bryant Manufacturers Parts Warranty
Service recall Furnace board showing e01 fault (pressure switch failure to close) Inducer never runs Measured 0V to the inducer Noted board making a funny sound, too Swapped with a new board Inducer now runs Found igniter broken off New board kit includes an igniter Replaced the igniter Furnace operating normally at this time
Upon arrival, inspected system and found inducer motor is non-operable. Control board throwing code 3 inducer motor error. Inducer motor has zero resistance, spins freely, but will not turn on. Called train and motor is available but extremely expensive being an ECM inducer. Recommend replacement over repair due to repair repair costs, quote for repair and quote number are in estimates in case replacement is not the route taken.
Performed heating maintenance on a 2001 Trane 78% efficient single stage natural gas furnace 16x25x1 filter is OK, **will need changed in another month or so** Pulled and clesned flame sensor Blower wheel is not the cleanest, but considering age, do not feel it is worth pursuing cleaning it Cleared pressure switch port Run tested furnace Gas pressure is 3.5"wc Combustion test numbers are in a healthy range 0ppm carbon monoxide in the ductwork Temperature rise 56⁰ Despite age, furnace is running OK and safe at this time.
Upon arrival inspected unit and found mouse nest in intake and burner compartment. Unit not running due to pressure switch error. Vacuum nest and remains from pipe and burner compartment and test run heating on propane and heat pump, verify proper operation for both functions. Unit is heating great at this time
Install replacement OEM Trane variable speed blower motor. Test run operation in fan only and geothermal heating stage 2 for multiple speed test.
Discussed issue over the phone. Everything he's describing is a setting issue with the thermostat. He will play with the settings and call us back Monday if needed.