Showed up in a timely manner and explained everything very well
Overall Experience
Quality
Price
Convenience
Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Excellent customer service and a tremendous knowledge of anything HVAC.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Seth and the guy with him were awesome!! They were super friendly and were very thorough in their explanation of what they were gonna do and when they were done, explained how to use the new humidifier with great detail!! The price was great too!!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Seth was professional. Did excellent propane to gas conversions on three furnaces.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
I really appreciate Seth taking the time to explain things to me in a way I could understand. Very friendly and knowledgeable!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
They did a great job! Helpful and professional. Neat work and on time.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
System has a failed 45uf capacitor for compressor operation. Replace failed capacitor and test run in heating mode. No other issues found or suspected during testing. Geothermal maintenence plan includes two visits for maintenence. Once in the spring for checking geothermal operation, and once in the fall for checking electric heat strips operation.
Gas heating preventative maintenance performed Check filter - 20x25x4 new today Clean flame sensor Inspect burners - clean Ohm test igniter: 54.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: panel ok - water supply very concerning (CPVC should not have a saddle valve on it) photo submitted. Wiring also improper allowing humidifier operation without gas heat or fan. Turned off currently. Inspect exhaust flu - no concerns with exhaust. No drain on intake allowing excess moisture into burner compartment. Set thermostat for heat Check amp draw on blower motor: 3.26 Check amp draw on inducer motor:0.62 Check delta T - 53° Furnace is in optimal running conditions
Install new Bryant HVAC system Equipment: Furnace- 927TA48080V17 Preferred 97, Up to 97% AFUE, Two-Stage, Variable 25-Speed, Non-Communicating, 4-Way Multipoise, Condensing Gas Furnace with InteliSense Technology, 80K, 4T, 17" width AC- 146SAN03600W 16 SEER2 Preferred Series Single-Stage Air Conditioner with Puron Advance Refrigerant, R-454B,IntelliSense Technology, 3 Ton, 208/230V, 1 Phase Coil- Matching cased coil *Honeywell T6 thermostat *LP conversion kit *April Aire 1210 High efficiency media air cleaner Installation: *Reconnect to existing gas line and high voltage electric *Transition to existing supply and return ductwork *Start up and commission the new system Warranty: 10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed)
Replace OEM WaterFurnace ABC control board Verified correct settings and operation
Performed gas line leak search on all reachable gas appliances and fittings. No indication of leaks in furnaces or in furnace room. Inspected reachable gas line in shop area. No indications of leaks. Walked around to look for any other propane powered equipment. Leaks detected on the propane powered forklift at the connection joint, and on one other forklift propane tank. Uncertain if this is the reason for the propane smell throughout the building, but no leaks were found on the main propane lines.
Propane heating preventative maintenance performed Check filter - 20x/5x1 clean Clean flame sensor Inspect burners - no concerns Ohm test igniter: spark no concerns Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.22 Check amp draw on inducer motor:0.43 Check delta T - 62° Furnace is in optimal running conditions Heat pump working well keeping up with demand
2013 climatemaster geo system maintenancs Very quickly found the system is low on refrigerant Wants quote to replace with gas furnace, already has natural gas service
Performed heating maintenance on a Lennox 93% efficient single stage natural gas furnace Cleared condensate lines of PVC shavings Condensate trap for the furnace is clear Removed burner box cover to gain access to the flame sensor and inspect burners Burners are in good shape Removed flame sensor and cleaned Reinstalled sensor and cover Blower wheel in OK condition Replaced 16x25x1 filter with customer-supplied one No visible signs of water leaks inside or around the furnace Run tested furnace Adjusted gas pressure to 3.5"wc with reference to the sealed burner box No adjustment required to blower speed Temperature rise leveled off at 53⁰, spec is 40-70⁰ Furnace is in good shape, operating within factory specifications at this time No concerns found on today's visit
Upon arrival inspected system and found noise coming from hot water regeneration on Waterfurnace. Turned off HWG on Waterfurnace and collected photos of pump for replacement
5 series water furnace Last lockout E11 fault (freeze protection 1 and 2 sensors) Suspect ABC board fault System is operating properly at the current time We will send a quote to replace ABC board ASAP
Preventative maintenence inspection on Waterfurnace 5 Series geothermal unit running in great condition. Current air filter is in good. UV bulb is operating properly. Visual inspection of blower and compressor compartments for any damage or loose wiring. None found. Test operation of electric heat strips. All are operating properly. Test run operation of geothermal heating aswell. Refrigerant pressures are within spec. Ground loop pressure is within spec. All parts and measurements are within spec. System is operating properly, efficiently and ready for Winter.
Install new Bryant HVAC system Equipment: Package H/P - 605CNXB60000 *Honeywell thermostat Installation: *Reconnect to existing high voltage electric circuit *Transition to existing supply and return ductwork *Start up and commission the new system Warranty: Bryant manufacturers parts warranty (Annual maintenance must be performed) 1 Year Westin Air labor warranty (Annual maintenance must be performed)
Factory heat exchanger parts warranty, labor not covered