725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for sunbury, oh

Rated 5.0 out of 5 stars based on 15 customer reviews

Chris was great

Showed up in a timely manner and explained everything very well

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Always there when I need them. And always ready to help out when I am in a pinch. Great guys to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service Exceeds Expectations

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Very professional Strive for excellence

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome

5 star plus

  • Overall Experience
  • Quality
  • Price
  • Convenience

5 Stars all the Way!

Excellent customer service and a tremendous knowledge of anything HVAC.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Great job - thanks so much!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome Service!!

Seth and the guy with him were awesome!! They were super friendly and were very thorough in their explanation of what they were gonna do and when they were done, explained how to use the new humidifier with great detail!! The price was great too!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Preventive maintenance inspection

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

Seth was professional. Did excellent propane to gas conversions on three furnaces.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Alway pleasant and efficient

  • Overall Experience
  • Quality
  • Price
  • Convenience

Took lots of time to explain things, thank you!

I really appreciate Seth taking the time to explain things to me in a way I could understand. Very friendly and knowledgeable!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Replacement System-Furnace & Heat Pump

  • Overall Experience
  • Quality
  • Price
  • Convenience

New roof top furnace

They did a great job! Helpful and professional. Neat work and on time.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome Geothermal service

Quick, efficient and friendly service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for sunbury, oh

seth p.

seth p. Job Checkin

Rebuild AC and furnace condensate drain for proper slope to the floor drain


seth p.

seth p. Job Checkin

2017 water furnace 5 series equipment is running in excellent condition and ready for the winter heating season Single pump non-pressurized variable speed flow center is programmed for 30% minimum and 40% maximum and currently flowing 9 GPM on high speed HP heating mode. Glycol antifreeze is confirmed at +18° Confirm operation of 10KW electric auxiliary heat strips with 39.9 amps at 240 volts Confirm K9 DHW relay operation and pump motor circulation in test mode Power flush condensate drain trap vinyl tubing and visually inspect condensate drain pump 20x25x5 air bear filter was replaced in April and still appears to be in like new condition AID computer scan confirms correct logging with E99 * 9 system resets and 0 logged trouble codes All equipment is clean safe and ready for heating mode


seth p.

seth p. Job Checkin

On site Inspection for custom maintenance plan


Nate G.

Nate G. Job Checkin

Diagnosed system low on refrigerant Got authorization to top off refrigerant and add leak sealant. System took 1.5lbs of refrigerant. Leak sealant may have a good chance of keeping the system running for a while longer. No guarantee on the leak actually stopping. We will email over a quote for a full system replacement.

Diagnosed system low on refrigerant
Got authorization to top off refrigerant and add leak sealant.
System took 1.5lbs of refrigerant.  Leak sealant may have a good chance of keeping the system running for a while longer.  No guarantee on the leak actually stopping. 

We will email over a quote for a full system replacement.

Nate G.

Nate G. Job Checkin

Performed 5 system cooling maintenance Changed all filters. Westin provided (4) 20x20x2 filters for the large unit. The rest were supplied by the VFW. Smaller unit servicing the pool table area has NO provision for installing a filter. Considering age (9yrs) and never having a filter, the indoor coil is in OK condition. Checked refrigerant charge on the 3 split systems The old unit is not running ideal numbers but still cooling. If it fails to keep up, replacement will be necessary. Washed Condenser coils. Used duct mastic to seal as much of the outdoor portion ductwork for the big bar area unit. Got in the attic to survey the ductwork for that system There appears to be abandoned ductwork for an entire system that no longer exists and the heat runs and returns have been tied into the big unit's ductwork. Solving the duct deficiencies will be a massive undertaking. Discussed adding two 24k btu mini split systems to the bar area to supplement the cooling on hot/busy days. Dan want

Performed 5 system cooling maintenance
Changed all filters.  Westin provided (4) 20x20x2 filters for the large unit.  The rest were supplied by the VFW.
Smaller unit servicing the pool table area has NO provision for installing a filter.  Considering age (9yrs) and never having a filter, the indoor coil is in OK condition.
Checked refrigerant charge on the 3 split systems
The old unit is not running ideal numbers but still cooling.  If it fails to keep up, replacement will be necessary.
Washed Condenser coils.
Used duct mastic to seal as much of the outdoor portion ductwork for the big bar area unit.
Got in the attic to survey the ductwork for that system
There appears to be abandoned ductwork for an entire system that no longer exists and the heat runs and returns have been tied into the big unit's ductwork.
Solving the duct deficiencies will be a massive undertaking.  
Discussed adding two 24k btu mini split systems to the bar area to supplement the cooling on hot/busy days.
Dan want

Jason D.

Jason D. Job Checkin

Job is complete at this time. Incoming propane pressures was low at 10.5 furnace calls for 11"h20. I informed the homeowner to have propane company increase it. Everything is running good at this time


Nate G.

Nate G. Job Checkin

Reconnected drain line on the back side of the indoor head


Nate G.

Nate G. Job Checkin

Went over options for helping the ducted AC system Proposed adding dampers to the lower level heat runs and adding 3 more heat runs to the upper area Requested quote for new mini split, ok with two single zone units Currently is 18,000 with two 12,000 indoors.

Went over options for helping the ducted AC system
Proposed adding dampers to the lower level heat runs and adding 3 more heat runs to the upper area
Requested quote for new mini split, ok with two single zone units
Currently is 18,000 with two 12,000 indoors.

Brandon P.

Brandon P. Job Checkin

Upon arrival, system was in cooling mode but set high enough that it would not attempt to run. Little spot of water in the attic upon first inspection. Could not find anything around the perimeter of the indoor coil that looked like water spots. Turned on AC to test run operation and see if any leaks were visible. Inspection around attic portion showed no external leaks. Inspected drain line termination at outside near condenser unit and there was no condensation dripping. Suspected drain line to be clogged. Used gallow gun to blow through drain line. Slight pressure build up at first, followed by an audible popping noise, and then water started to flow out of the drain. Initial water was chunky and murky, and gradually got cleaner. Inspected attic portion again and found no leaks. System is properly draining and ready for operation.


Jason D.

Jason D. Job Checkin

SOLD: 08/20/2025 9:29:32 AM - Option 3 Install new Bryant HVAC system Equipment: Furnace-926TC66100V21 Preferred, 96" AFUE, Two Stage, 4-Way Multipoise, VCT ECM, Gas Furnace, 100K, 21" width Serial# 1825A58730 AC-GA5SAN54200W 14.3 SEER2 Single-Stage Air Conditioner with Puron Advance Refrigerant, R-454B, 3.5 Ton, 208/230 Volt Serial# 3025G04973 Coil- CVAVA4221XMAEAAA Serial# 1725J6352 *Honeywell Vision Pro 8000 thermostat *AprilAire 1210 High efficiency media air cleaner *LP conversion kit Installation: *Reconnect to existing gas line and high voltage electric *Transition to existing supply and return ductwork *Install new PVC furnace venting *Start up and commission the new system Warranty: 10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed)


Graham M.

Graham M. Job Checkin

Replace evaporator coil 12° subcool


seth p.

seth p. Job Checkin

2009 carrier 13 seer 2.5 ton r410a equipment is running in very good condition after maintenance cleaning and cooling system service perform today Taking into consideration the homeowners concerns of long run times to achieve the temperature in summer the evaporator coil was visually inspected, the drain trap was flushed & scrubbed, and maximum speed blower was confirmed. The air filter is acceptable and on schedule with homeowner. Evaporator coil inspection reveals light buildup that is not a concern today. Future coil cleanings can be performed but are not really necessary at this point The outdoor equipment inspection revealed heavy buildup on 25% Plus of the condenser coil creating high head pressures and hot liquid temperatures. Heavy-duty water flush of the condenser coil resolved all issues outside and the refrigerant pressures are perfectly within specs stated on the outdoor equipment. The 370 volt power supply is slightly low but still within specs at 38.1 / 5.0 All equipmen


Nate G.

Nate G. Job Checkin

Split system off the front parking lot not running at all Diagnosed failed transformer on the furnace Replaced transformer System working normally at this time.


Brandon P.

Brandon P. Job Checkin

Service warranty. Internal drain trap hose disconnected from drain pan nipple causing water to drain into furnace cabinet. No electronics were touched by water. Attempted to remove as much water as possible. Told Greg that it was pure water as he had a gate up to keepcthe cat away, and that there was still a bit left and it would dry up on its own.


seth p.

seth p. Job Checkin

Performed cooling maintenance on a Goodman system 14x20x1 filter is OK, change after another month or two Blower OK Blower speed too high, bumped it down one speed lower from factory high setting Outdoor coil 50% plugged with pollen Removed top from unit, washed coil from inside-out Capacitor tested good Wiring in good shape Refrigerant charge OK System operating normally at this time

Performed cooling maintenance on a Goodman system
14x20x1 filter is OK, change after another month or two
Blower OK
Blower speed too high, bumped it down one speed lower from factory high setting 
Outdoor coil 50% plugged with pollen
Removed top from unit, washed coil from inside-out
Capacitor tested good
Wiring in good shape
Refrigerant charge OK
System operating normally at this time