18341 E. El Buho Pequeno Gold
Canyon, AZ 85118

Local Reviews
for peoria, az

Rated 5.0 out of 5 stars based on 4 customer reviews

Fast service

was very happy with the same day service and the technicion

  • Overall Experience
  • Quality
  • Price
  • Convenience

super service

Carlos always knows what he is doing. We always ask for him. He knew the problem immediately and fixed it fast!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

refrig repair

Did a great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for peoria, az

Paul  S.

Paul S. Job Checkin

Washer Service Call See Invoice For Details CONCERN: washer does not complete cycle. DIAGNOSTIC: entered washer in service mode. Tested all components, passed. Ran washer in rinse and spin. Washer completed cycle. At this time washer is operating normal.


Paul  S.

Paul S. Job Checkin

CONCERN: Customer reports washer water inlet is not working properly. CAUSE: Found washer water valve failed. CORRECTION: Replaced washer water valve and tested. Operation now normal. NOTE: After repairs were completed inspected for leaks, no leaks at time of completion


Company Owner .

Company Owner . Job Checkin

CONCERN Customer reports refrigerator Is not cooling. CAUSE: Found Evap fan jammed. CORRECTION: Freed evap fan and tested. Operation now normal. CONCERN Customer reports refrigerator is not dispensing water. CAUSE: Found water reservoir iced up. CORRECTION: Melted ice in reservoir and tested. Operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports KitchenAid microwave is not working properly. Model KEMS2055SSS-2 CAUSE: Tested Microwave door switches for continuity, found microwave interlock door switches have electrical short and failed. CORRECTION: Replace microwave interlock door switches and tested. Operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports refrigerator is leaking water. DIAGNOSTIC AND CAUSE: Inspected water supply line for leaks, no leaks at the refrigerator water supply line. Inspected internal water refrigerator water lines for leaks, internal refrigerator water line are normal at the time of inspection. Inspected refrigerator defrost drain line for water leaks, found the source of the leak coming from the refrigerator defrost drain. Removed freezer panel to inspect for clogged drain line. Found the defrost drain restricted with ice and debris. CORRECTION: Cleared the refrigerator defrost drain of ice and debris, operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports microwave is not working. DIAGNOSTIC AND CAUSE: Inspected power supply at the wall for 120V, voltage at supply line normal at time of inspection. Inspected control board for visible signs of shorts, no signs of shorts a the control board. Inspected microwave 20 amp safety fuse for shorts. Microwave fuse shorted. CORRECTION: Replaced microwave fuse and tested, operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Refrigerator section is not getting cold. DIAGNOSTIC AND CAUSE: Inspected voltage from terminal block to compressor, voltage normal at the time of inspection. Tested compressor operation, compressor operation normal at the time of inspection. Inspected voltage to evaporator fan motor, voltage normal at the time of inspection. Found evaporator fan motor failed. CORRECTION: Replaced refrigerator evaporator fan motor and tested. Operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports ice maker is not making ice. DIAGNOSTIC AND CAUSE: Inspected water supply lines for leaks, no leaks from supply lines at the time of inspection. Inspected freezer for proper temperature output, temperature output in freezer normal at the time of inspection. Inspected for proper voltage to the ice maker, voltage to ice maker is normal at the time of inspection.Found voltage to the Ice maker normal however ice maker will not call for water from the refrigerator water valve. Found the ice maker failed. CORRECTION: Replaced ice maker and tested. Operation now normal CONCERN: Customer reports refrigerator is leaking water onto floor. DIAGNOSTIC AND CAUSE: Inspected water supply line to refrigerator for leaks, no leaks found at this time. Inspected water valve for leaks, found water valve failure. CORRECTION: Replaced water valve and tested. Operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports refrigerator is not working properly. DIAGNOSTIC AND CAUSE: Inspected refrigerator for proper voltage supply, voltage is normal at the time of inspection. Inspected for proper voltage from terminal block to control, voltage is normal at the time of inspection. Inspected voltage from control to DC inverter, found voltage supply to the inverter normal however no voltage coming out of the inverter to the compressor. Found compressor inverter control board failed. CORRECTION: Replaced compressor inverter control board and tested. Operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports washer water inlet is not working properly. CAUSE: Found washer water valve failed. CORRECTION: Replaced washer water valve and tested. Operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Refrigerator section is not getting cold. DIAGNOSTIC AND CAUSE: Inspected voltage from terminal block to compressor, voltage normal at the time of inspection. Tested compressor operation, compressor operation normal at the time of inspection. Inspected voltage to evaporator fan motor, voltage normal at the time of inspection. Found evaporator fan motor failed. CORRECTION: Replaced refrigerator evaporator fan motor and tested. Operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports Oven is making noise CAUSE: Found bad clock N/A CORRECTION: Disable clock.


Company Owner .

Company Owner . Job Checkin

CONCERN: Refrigerator is not working properly. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage, voltage at wall outlet was normal at the time of inspection. Inspected input voltage to compressor, input voltage at compressor was normal at the time of inspection. Inspected refrigerator thermostat cold control operation, found refrigerator cold control failed. CORRECTION: Replaced refrigerator cold control and tested. Operation now normal.


Paul  S.

Paul S. Job Checkin

CONCERN: Customer reports dishwasher door is not working properly. CAUSE: Found dishwasher door latch failed. CORRECTION: Replaced dishwasher door latch and tested, operation now normal.