Arrived onsite and the resident showed us all the outdoor outlets that were in rough condition to say the least. Some were burnt, some were broken, and some had terrible weather aging and lack of weatherproofing. I inspected the house and panel while Tyler opened all of the outside outlets up. I found 3 multifeeds that can be corrected by installing 2 pole breakers so both legs of the circuit are equally protected, as opposed to the current setup where one half of the circuit can damage the other half. I also found a lack of bonding at the hot water heater that Is needed. She mentioned she is going to have work done to the kitchen and other areas in the future but she wanted to address safety concerns. I talked to her about a whole home surge protector and explained so she understands what it is and what it does, as well as discussed the Replacement of their old smoke detectors as well. We went over options and the membership but because of life circumstances at the moment she cannot