Knowledgeable, polite efficient
Response from Light'em Up Electric:
Thank you for the 5-Star Review! We appreciate the opportunity to provide excellent service!
I needed a new outlet and cable TV connect. It was a lot of work and there were several options to make it work. Craig worked with me on making sure what I needed got done with the least amount of cutting in walls. It was all done in a timely manner, the space was cleaned/tidied up, I was left with thorough instructions, info on the warranty, and I was thrilled with the finished work!
I could not be more impressed with this company. Every aspect of their business is user friendly, cost effective and customer oriented. The owner and employees can all be very proud of this business. Outstanding knowledge and service!
They called me back and we're able to work me in the same day. It turned out to be something small, but I still had the AC service done on my two units. They did a great job.
Fixed a junction box out front. Installed a photo cell for carport.
There is a short in the bedroom light fixture. Recommend a light fixture replacement. Install dedicated 20amp circuit for living room tv.
Replace eyebolt home owner call power company to reattach power to anchor
Gave estimate to install a dedicated circuit to the irrigation system
Arrived at home and inspected service....eyebolt has been ripped out of home...power still on, meter is on back side of home with service wire exposed(no conduit)........ left estimates option 1: replace eye bolt....option 2 eyebolt and safety check up of electrical system ......option 3: upgrade service to today’s code and safety standards
Redevice whole home , and perform panel rejuvenation
Diagnosed back bedroom fan. Found room had no power. Checked all breakers in electrical panel. Found some tandem breakers breakers broken by whom ever installed them to make them fit this panel. Left quote to ran bedroom of existing circuit to cut down on Sheetrock damage
Replace panel , grounding , surge , esp, redevice only dining room
Replace panel , grounding , surge , esp, redevice only dining room
Customer is cancelling appointment at this time. Replace meter obsolete meter guts
Customer is cancelling appointment at this time. Replace meter obsolete meter guts
Dishwasher is currently connected to the kitchen circuit and needs to be on a dedicated circuit
Responded to call for power is flickering. Upon arrival customer advised during heavy usage her electrical power is flickering. Inspected electrical panel. Found no issues with power. Powered ac, stove, and dryer on at the same time and terminated main power. Waited 3 minutes. Then restored main power. After power restore observed power is surging in the home. Tested main feed to electrical panel. Found 95 volts on B phase and 154 volts on a phase. Determined issue is a floating neutral. Contacted Ga Power and waited for their arrival due to they have been contacted about the problem previously but stated there was no issues. Remade all main neutral connections. Requested for Ga Power to inspect all neutral connections from transformer to home. Ga Power tech tightened all crimps at transformer and at weather head. After Ga Power repairs were made found no issues with electrical in the home. Ga Power tech advised he will put an order in to have an engineer respond and record power comin
Responded to call for needs attic fan replaced. Upon arrival customer advised whole house fan is making a noise. After locating attic access found attic access was cut in at the eve of the home and is not sufficient to access attic space. Inspected whole house fan from hall. Found belt is extremely worn causing the noise. Advised customer of findings. Advised customer no access to attic. Thank you. Eric Messer.