105 Village Walk Suite 178
Dallas, GA 30132
678-540-5715

Local Reviews
for jonesboro, ga

Rated 5.0 out of 5 stars based on 6 customer reviews

Great Service

Eric was on time and very efficient. He completed his job in a timely manner and was very professional.


Response from Light'em Up Electric:

Thank you for the 5-Star Review! We would like to invite you to take part in our referral program, if a new customer gives us your name, we'll send you a $50.00 Kroger gift card!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Mr. Eric Weser handled himself in a knowledgeable and professional manner. He presented me with options after a thorough inspection of the electrical issues. I would definitely recommend him and The Light Em Up Company for your electrical needs.


Response from Light'em Up Electric:

Thank you for the review! Please make sure to take advantage of our Referral program and we'll send you a $50.00 Kroger Gift Card!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Terrific service

Craig is the best electrician we have ever had, he's thorough, he is Legendary" and he cares about his customers!!!


Response from Light'em Up Electric:

Thanks! You can be a part of our 'legendary' referral program. If a customer gives us your name as a point of contact, we'll send you a $50.00 gift card to Kroger!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Craig explain all that needs to be done.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great first impression

Justin was a very knowledgeable, understanding and patient with all my questions. He was very nice and based on the quote I got today, he is a very good listener. The quote was exactly what I asked for and spelled out the exact cost for the projects and variables I asked for. I have to say an unexpectedly excellent first impression.

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

great job.


Response from Light'em Up Electric:

Thank you for the review. We appreciate any and all feedback. Please feel free to call the office at 678-540-5715 if you have any questions or concerns. Have a great day!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for jonesboro, ga

Craig  W.

Craig W. Job Checkin

Left multiple quotes for needed work. Found busbar in panel burnt panel with have to be replaced. Also service is just hanging by wires


Craig  W.

Craig W. Job Checkin

Installed new fan in living room. And new Led fixture in kitchen. While at Electrical panel noticed double taps and non ul listed breakers. Performed panel rejuvenation. Thank you for your business.


Jimmy H.

Jimmy H. Job Checkin

The 29 was waved because was not told over the phone


Eric M.

Eric M. Job Checkin

Responded to call for outlets not working and doorbell install. Upon arrival customer advised gfci on the back of the home and 2 gfci outlets in the master bath are not working. Customer stated also need ring doorbell installed. Inspected outlets. Found no power to all gfci outlets that are not working. Inspected breakers to ensure voltage from panel. Found all breakers are operating properly at this time. Advised customer of worn breakers and double tapped neutrals. Advised customer of the options. Customer agreed to option. Customer declined panel repairs at this time. Diagnosed gfci outlets without power. Found gfci in garage is wired incorrectly. Wired gfci in garage correctly. Tested gfci on back of home. Power restored. Tested gfci outlets in master bath. Found outlets in master bath still did not work. Inspected wiring to master bath gfci outlets. Found both gfci outlets wired incorrectly and corrected. Tested outlets. All outages power restored. Installed new ring doorbell. A


Patrick K.

Patrick K. Job Checkin

Collecting 500.00 today due to bad receiver fro one fane. Customer will call us back when receiver comes in. All of job is complete minus receiver. Recommend replaceing existing box in ceiling. On fan due tue box wiggling on stud. Ceiling fan


Eric M.

Eric M. Job Checkin

Responded to call for power loss in guest bedrooms. Upon arrival customer advised power is intermittent in both rooms and breaker is not tripping at the time of the power loss but power restores without any repair. Inspected guest bedrooms. Tested all outlets in both rooms. With outlet tester found multiple outlets have failing wiring connections. Advised customer. Inspected panel. Found double tapped neutrals and 25+ year old breakers that are weak and worn. Also found a small amount of corrosion on the bus bars in the panel. Advised customer of the concerns with corrosion, double tapped neutrals, and weak connections at switches and outlets. While inspecting panel customer observed arching at the bedroom breaker. Advised customer with multiple issues with the bedroom electrical circuit replacing the breaker is needed to prevent further damage but is not guaranteed to completely eliminate the power loss issues. Customer agreed to replacing the breaker. Removed existing tandem breake


Justin S.

Justin S. Job Checkin

Changed ballast in kitchen over counter.....also replaced bad outlet in middle bedroom..... checked other outlets and switches on that circuit and noticed they were backstabbed, this type of wiring over time will become worn causing loose or loss of connection and heating, melting and burning of outlet in wall


Craig  W.

Craig W. Job Checkin

Arrived at home and found back security light on left side not working. Also the others around home were wired incorrectly. They just had Romex wire ran on home. Installed new seal-tight conduit. And demoed old food light. Also brought the front security lights up to code. They were also wired incorrectly. While performing home check up. Found home didn’t have proper gfci protection. We installed 3 gfci outlets. Electrical panel looked good. Panel does have surge protection located at bottom of panel. Home also has surge protection at meter though power company. Which can be discontinued due to being double protected. Thank you for your business!! Craig Windom


Craig  W.

Craig W. Job Checkin

Replaced two switches one controlling fan in kitchen. Other to light in basement stairwell. Also adjusted can socket in hallway. Advised customer home doesn’t have proper gfci protection. Also advised about electrical panel. Having original breakers and double tapped neutrals.


Patrick K.

Patrick K. Job Checkin

Install 3 outdoor fixtures and install keyless fixture in dressing room


DJ P.

DJ P. Job Checkin

Performed a breaker transplant, replaced all switches and outlets in home. 1 year ESP


Justin S.

Justin S. Job Checkin

New fixtures


Justin S.

Justin S. Job Checkin

New fixtures


Jake E.

Jake E. Job Checkin

Gave estimate to install 2 switch legs for a pair of wall sconces stationing the back door


Justin S.

Justin S. Job Checkin

Install fixtures throughout home