I would call them again.
Response from Light'em Up Electric:
Thank you for the review! Please take advantage of our referral program and receive a $50.00 Gift Card to Kroger!
Response from Light'em Up Electric:
Thank you for the GREAT rating!
Dan did a fantastic job finding what caused part of my house to be out of power. He replaced one light switch and one power outlet and solved the problem. He was a pleasure to do business with. I have several more projects to do at my house and I will definitely use this company again.
Response from Light'em Up Electric:
Angela, thank you for the 5-Star review! We're glad we could help fix the first of (hopefully) many projects around your home!
VERY PLEASED with the service, definitely the Electrician, Ian Weaver👍 Helpful, and very prompt and accommodating . 5⭐️
Very impressed with Customer Service.
Electrician was running late but they kept me well informed even had time to run out and do some errands got back and there he was
Response from Light'em Up Electric:
Thank you for the review. We appreciate any and all feedback. Please feel free to call the office at 678-540-5715 if you have any questions or concerns. Have a great day! ?
Replaced murray panel with cutler hammer br panel. Panel was over heated and burnt. 5 year warranty on breakers and life time on labor. Customer understands issue found in home inspection and does not want to move forward with work. Found multiple loose o and ungrounded outlets.
Moved 8 lights in the downstairs media room and added 8 lights on a dimmer in the media room
Installed gfci with bubble cover on back porch by back door. Also installed 4 led trims on back porch recesseced can light.
Replace overloaded panel, grounding system, disposal circuit surge protection.
Replace overloaded panel, grounding system, disposal circuit surge protection.
Upon arrival found that panel was rusted and had corrosion to main service lugs and that two wires had completely burned we replaced the panel and installed a ceiling fan
Upon arrival found that panel was rusted and had corrosion to main service lugs and that two wires had completely burned we replaced the panel and installed a ceiling fan
Replaced photo cell for front garage light
Installed 4 data jacks. Advised customer to contact a networking technician to set up network. Thank you. Eric Messer.
Installed 4 new Ethernet drops in building. One in conference room and the two offices down from it. And one in office by copy machine. Also installed a new quad outlet in office by copy room. Cable provider will do punch downs at locations needed.
Ran diagnostic found the box is mounted in between the sink and the pool pumps and is mounted to that slab the j Xbox is cracked and not terminated properly
Left qoute to install 50 amp charger in garage. Would run wire exposed and put in conduit. Install breaker and plug is included
Preform electrical inspection: the panel busbar is burnt in one place and getting in regular voltage readings. Highly recommend a panel replacement, two circuit exams and a whole home electrical inspection......examined electrical circuit in master bedroom.....disconnected switch to flood lights at Jeff’s request....outside electrical circuit examination found recepticals on the same circuit as bathroom in main level bathroom found loose wire in bathroom reconnected wire tightened all connections recepticals work properly...removed old electrical panel in garage and replaced with new electrical panel
Ran diagnostic found the wire for the fan was lose up in the canopy relanded wire and replaced bulbs now the kitchen fan is working also ran panel inspection found a braker is double taped with a 15amp added wire and it is a 20 amp braker and the neutrals and grounds are typed together coustomer is awair of the code violations and requests no repair at this time left estimate