Troubleshot flickering lights in the living room. Inspected the wiring and found a loose neutral connection at the breaker panel. Tightened the connection and replaced a worn-out Square D breaker. Tested all affected lights, confirming stable power and no further flickering. Ensured that the entire panel was securely wired.
Replaced outdated two-prong outlets with new Leviton tamper-resistant three-prong outlets in a bedroom. Ran new grounding wires to ensure compliance with current electrical codes. Tested each outlet for proper voltage and grounding. The updated outlets now provide safe, reliable power for modern devices.
I worked on a Tesla EV charger installation in Alexandria, VA today. After confirming the home’s electrical panel could handle the load, I installed a Tesla Wall Connector. I wired it into the panel, mounted the charger on the wall, and tested the system by plugging in the client’s vehicle to ensure it was working.
This morning in Alexandria, VA, I worked on new construction electrical installation. I ran conduit and wired several rooms with 12/2 Romex cable for standard outlets and lights. After installing electrical boxes, I connected the wires to the panel, mounted the outlets, and tested the circuits for proper voltage.
In Alexandria, VA, I diagnosed a tripping circuit breaker caused by a short circuit in the wiring. Using a multimeter, I located the damaged insulation within the circuit. I repaired the faulty section with new 12-gauge Romex wire, replaced the breaker, and tested the circuit to confirm proper operation and load capacity.
In Alexandria, VA, I installed new LED pendant lights over a kitchen island. I routed new wiring from the ceiling junction box, mounted the fixtures securely, and connected them to a dimmer switch for adjustable brightness. After installation, I tested the lights for proper operation, adding both functionality and style to the space.
I performed electrical repairs in the residence of our client in Alexandria, replacing damaged wiring in a wall outlet circuit. I used 12-gauge Romex wire to rewire the circuit, installed a new Leviton GFCI outlet, and ensured the breaker was properly rated. Conducted a voltage test to confirm safe operation.
Today, I replaced several outlets in an Alexandria, VA home, upgrading to Leviton tamper-resistant outlets for child safety. I disconnected the existing wiring, attached the new outlets, and ensured all connections were properly grounded. Checked each outlet for voltage and proper operation after installation.
I installed a Tesla home EV charger for a customer in Alexandria this morning. After assessing their electrical panel, I ran a dedicated 240-volt line from the main panel to the garage. I used 6 AWG copper wire and a 50-amp breaker to ensure proper capacity. The installation was tested and completed successfully.
I installed an EV charger for a Nissan Leaf. The installation involved running a new 240V circuit from the panel to the garage. I mounted a JuiceBox 40 Level 2 charger, connected it to the power source, and tested the charging unit for proper operation.
I repaired a tripped breaker issue for a homeowner. The breaker was frequently tripping due to an overloaded circuit. I identified the problem, separated the loads onto different circuits, and installed a new Square D 15-amp breaker. The system is now running smoothly with no further issues.
I installed whole home surge protection using a Siemens FirstSurge Type 2 device. The surge protector was connected to the main panel to guard against voltage spikes and surges. After installation, I tested the device to ensure proper operation, securing the home’s electronics from future surges.
Installed an Intermatic IG1240RC3 whole-house surge protector. Mounted the unit adjacent to the main panel and connected it to a dedicated 20-amp breaker. Ensured all wiring was correctly terminated and that the ground connections were secure. Tested the system to ensure it was properly protecting the home from voltage spikes.
Performed an electrical safety inspection on a home’s aging wiring system. Inspected all circuits for potential overloads, checked the condition of the breaker panel, and tested outlets for proper polarity and grounding. Replaced two outdated GFCI outlets with new Leviton models. Provided the homeowner with a detailed report, including recommendations for future upgrades.
Installed a Nest Learning Thermostat and integrated it with the home’s HVAC system. Replaced the existing thermostat with the Nest unit, connected it to the Wi-Fi network, and configured it through the Nest app. Tested the system to ensure it was properly adjusting the temperature and could be controlled remotely via smartphone.