Mason C.

Mason C. Job Checkin

Came out today due to the indoor unit producing a burning smell. Upon inspection of the outdoor system found it is a R 22 that is from 2006. Upon inspection of the indoor system found heat pump that is from 2005. Upon testing the outdoor unit found that the refrigerant charger is good. The contactor is burnt and pitted, but the 24 V coil is OK. The capacitor for the outdoor system is within range. Upon inspection of the indoor system found a lot of biological growth inside of the system. The indoor coil and indoor blower will have lots to build up. Due to the amount of stress and buildup on the blower will cleaning this motor could completely caused this motor to fail. Upon inspection of the blower motor itself, found oil from around the motor, which is indicating that the motor has overheated. Upon testing the blower capacitor found it was bad. After full inspection of the system, found nothing that was burnt or any burning wires. Performed test to ensure that the heat strips were not


Dalton C.

Dalton C. Job Checkin

Found system to be over charged. Removed 1.3lbs from system and it is now cooling correctly. Compressor is row running at 9 amps was previously running at 16.


Dalton C.

Dalton C. Job Checkin

Based on our findings today, it might be time to think about getting a brand new system. Customer stated they have been having issues for two years with a leak in the system. Had refrigerate put in the system two days ago and it has almost completely leaked back out. System is over ten years old. Have options to do a leak search and repair the unit, customer elected to have a quote for replacement.


Mark  H.

Mark H. Job Checkin

Performed diagnostic on upstairs 6yr old Lennox heat pump, upon arrival customer stated unit had water in the pan and he can see water dripping from the side of the unit, checked tstat, already in ac mode set at 77 reading 77, upon going in attic found secondary drain pan with water, recommended removing all water from pan, customer declined stated he will remove it himself, also recommend TE flood protection such as wet switch to prevent pan from filling with water, customer declined as well due to having a float switch, I did explain that float switch will not activate until pan is full of water, inspected air handler, found primary pan full of water, recommend cleaning and flushing drain line, customer approved, flushed and cleaned drain line, now draining properly,inspected duct work and airflow, explain to customer he is short on suppply air for a 3ton unit, requires 1200cfm, customer only has 780cfm supply and 1120cfm in return, recommend increasing 10” to a 14”, customer decline


Joel C.

Joel C. Job Checkin

Removed two commercial grade charge points and provided and installed to universal Tesla magic dock chargers.


Mike P.

Mike P. Job Checkin

Ame out for main line leaking gave estimate customer agreed dig up line made repair tested no failure at this time. Gave estimate for replacement.