Absolute professional, knowledgeable, courteous, did what he said he was gonna do did it well.
Overall Experience
Quality
Price
Convenience
Ricky Newsome from TE Certified did an excellent job repairing a complex problem related to our water heater! He was very professional, knowledgeable, and congenial. We recommend him and TE Certified to anyone requiring this sort of service.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Griffin was great. He went above and beyond and gave great insight to the problem and how to mitigate for the future.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
So happy with Luis and his crew and the excellent electrical job the did and the work that they will be doing next week. Appreciated his no pressure approach and information to help make an informed decision for our home.
Overall Experience
Quality
Price
Convenience
David was amazing to work with. He came in fixed things that my contractor didn’t do correctly. In and out in a few hours.
Overall Experience
Quality
Price
Convenience
Total professional, understood my concerns, communicated clearly. Got the job done. I’m satisfied customer.
Overall Experience
Quality
Price
Convenience
Both technicians were professional, knowledgeable and courteous.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Today I was called out because the lights in the downstairs living room stopped working. Upon diagnosis I found a GFI outlet that was under the TV that was melted damaging some of the wiring in the box. Luckily, I was able to salvage the existing wiring by trimming back and rewiring The existing wiring with jumpers and I installed a new tamper resistant GFI.
Dedicated circuit to garage door openers and kitchen lights.
Came out to install 3 Aprilaire SpaceGard 201 filters for main floor, basement, and upstairs systems. Strongly recommended signing up for our Home Care plan, customer will consider for future visit
For this job, I replaced a bad breaker and I replaced the batteries in all the smoke detectors.
Bandage repair address is a problem with no warranty. We are only addressing the symptom.
Homeowner called because water heater was leaking. The water heater was six years old outside of manufacturers warranty and what was leaking was the T&P valve. I also checked the pressure and the pressure was sitting at 145 psi. I installed a new 50 gallon gas water heater, and a new PRV on the main line to bring the pressure down to 65 psi. All the work was tested for leaks to ensure proper function.
Directional boar new main line with a sleeve for protection. Also added new prv and main shutoff valve
Directional boar new main line with a sleeve for protection. I added a temporary fix on waterline. She has paid 2800 and the remainder she needs to pay us 3163.
Performed 1 system homecare, replaced (1) 16x25x1 filter. Inspected the system in heating and cooling modes, cleared drain lines and tested all electrical and mechanical components. Today I installed an APCOX UV light in the system to prevent biological growth.
As we arrived today, we came to do a home care and we also performed a troubleshootingon a problem in the kitchen area. We found that there were three different double tap circuits in the electrical panel. They were not landed on the breaker, but they were tapped together inside of the panel. You cannot have neutrals touching each other from two different circuits going to the same breaker. This could make it trip quite frequently and is also a potential fire hazard. We did find that the dishwasher and disposal Were also on the same circuit, which is where the problem was taking place in the kitchen. Each of these according NEC (national electrical code) are supposed to have a dedicated circuit. Any licensed electrician should know better than this! I’m attaching two separate estimates to fix the problem. It was very nice meeting you today mrs. Miller! If you have any questions about the estimate or need anything else, feel free to give me a call anytime. Thank you, Brandon
Flushed heaters and changed expansion tank due to undersize expansion tank and yearly service on water heaters. Let homeowner know that they need to install boiler drain if hot water does not get to fixtures as fast as it did.
Came out for Home Care heating/cooling check on 3 AC/90% Furnaces. 2 in attic 2 in basement. 2019 Goodman Zoned system for master bedroom and guest bedroom in attic, 2022 Lennox system for upstairs. 1998 Carrier system for basement, 2019/2022 Lennox AC/Goodman Furnace for main floor. Cleared all condensate lines, found no TE Standard flood protection for either systems, recommend adding. Found no UV Protection for either systems recommended APCO-Xs with air scrubbers. For older Carrier furnace found weak 7.5mfd capacitor. Main recommendation for this system is to consider looking into replacing due to age and obsolete refrigerant. Still left quote incase they would like to proactively replace weak capacitor. All 3 systems cooling and heating at this time. Recommended replacing all 3 space guard 16x25x5 filters. Not in truck stock, customer approved for us to come back out and install once we order them. Set up with dispatch. Left inspection reports and quotes via email
Customers kitchen sink is clogged. Used camera to trace drain to exterior to determine where it exits.
This was a pre purchase inspection of the plumbing system. The shower drain in the master needs to be replaced due to leaking. The water heater is old and recommending replacement soon. The kitchen drain needs to be replaced due to it being back pitched. The garbage disposal will need to be replaced. Had difficulty with operation of the kitchen faucet. Seal the hose bibbs and vacuum breakers need to be installed.
Tub spout in master shower was bent downwards due to it being leaned on for support. Cut and repiped spout connection as well replaced spout onto new connection. Tested and checked for leaks