7415 Whitehall St. #119
Richland Hills, TX 76118
682-262-5759

Local Reviews
for arlington, tx

Rated 5.0 out of 5 stars based on 7 customer reviews

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Took care of the problem quickly

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Did an excellent job. I really enjoyed that they got the job done quickly and rightly. eexcellant Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Job Done

Rey was very professional and represented his company well.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Mike, explained everything to us, discussed our options and was very professional!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

a professional from start to finish.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for arlington, tx

Rey V.

Rey V. Job Checkin

Arrived on the job site and the customer stated that they had an unused oven circuit and wanted it converted into a standard 120-volt outlet. We installed a 20-amp CL breaker in the GE panel and converted the existing 8/3 wiring by splicing it to 12-gauge wire feeding the new outlet. After testing, everything is working properly. The customer was informed that all work performed includes a five-year warranty. We also completed a safety evaluation and noted that the electrical panel is outdated and has several issues that need attention. We provided solutions for upgrading the panel, meter base, and additional recommended improvements. We will be calling next Saturday, December 6th, to review the options with her husband. The customer is 100% satisfied with today’s visit.

Arrived on the job site and the customer stated that they had an unused oven circuit and wanted it converted into a standard 120-volt outlet. We installed a 20-amp CL breaker in the GE panel and converted the existing 8/3 wiring by splicing it to 12-gauge wire feeding the new outlet. After testing, everything is working properly.

The customer was informed that all work performed includes a five-year warranty. We also completed a safety evaluation and noted that the electrical panel is outdated and has several issues that need attention. We provided solutions for upgrading the panel, meter base, and additional recommended improvements.

We will be calling next Saturday, December 6th, to review the options with her husband. The customer is 100% satisfied with today’s visit. Arrived on the job site and the customer stated that they had an unused oven circuit and wanted it converted into a standard 120-volt outlet. We installed a 20-amp CL breaker in the GE panel and converted the existing 8/3 wiring by splicing it to 12-gauge wire feeding the new outlet. After testing, everything is working properly.

The customer was informed that all work performed includes a five-year warranty. We also completed a safety evaluation and noted that the electrical panel is outdated and has several issues that need attention. We provided solutions for upgrading the panel, meter base, and additional recommended improvements.

We will be calling next Saturday, December 6th, to review the options with her husband. The customer is 100% satisfied with today’s visit.

Rey V.

Rey V. Job Checkin

Arrived on the job site. The customer stated that the front porch outlet was not working. I charged a minor diagnostic fee to troubleshoot the issue. During the diagnostic, I noticed that the two back-door outlets— which should be tied into the same circuit—are powered 24/7. When testing these outlets, they showed as “GFCI protected,” but they do not trip the GFCI, indicating they were previously protected but are no longer tied into the current GFCI. The customer mentioned that the home recently underwent a remodel, converting a single-story home into a two-story. All the remodeling work is still under the contractor’s warranty. I explained that I could continue diagnosing the issue, but I could not replace or modify any wiring, as that could void the homeowner’s remodel warranty. I also found that the two outdoor outlets that remain energized are tied into the “new plugs” circuit and not the same circuit as the outdoor GFCI. When attempting to reset the GFCI, it trips instantly, wh

Arrived on the job site. The customer stated that the front porch outlet was not working. I charged a minor diagnostic fee to troubleshoot the issue. During the diagnostic, I noticed that the two back-door outlets— which should be tied into the same circuit—are powered 24/7. When testing these outlets, they showed as “GFCI protected,” but they do not trip the GFCI, indicating they were previously protected but are no longer tied into the current GFCI.

The customer mentioned that the home recently underwent a remodel, converting a single-story home into a two-story. All the remodeling work is still under the contractor’s warranty. I explained that I could continue diagnosing the issue, but I could not replace or modify any wiring, as that could void the homeowner’s remodel warranty.

I also found that the two outdoor outlets that remain energized are tied into the “new plugs” circuit and not the same circuit as the outdoor GFCI. When attempting to reset the GFCI, it trips instantly, wh Arrived on the job site. The customer stated that the front porch outlet was not working. I charged a minor diagnostic fee to troubleshoot the issue. During the diagnostic, I noticed that the two back-door outlets— which should be tied into the same circuit—are powered 24/7. When testing these outlets, they showed as “GFCI protected,” but they do not trip the GFCI, indicating they were previously protected but are no longer tied into the current GFCI.

The customer mentioned that the home recently underwent a remodel, converting a single-story home into a two-story. All the remodeling work is still under the contractor’s warranty. I explained that I could continue diagnosing the issue, but I could not replace or modify any wiring, as that could void the homeowner’s remodel warranty.

I also found that the two outdoor outlets that remain energized are tied into the “new plugs” circuit and not the same circuit as the outdoor GFCI. When attempting to reset the GFCI, it trips instantly, wh

Tyler B.

Tyler B. Job Checkin

- Replace 9yr old electric rheem w new premium state unit - replace all old connections to the unit. - install flood stop automatic shutoff valve ( battery powered ). - install electrical disconnect per code. - permit and inspection ( through the city of arlington ) - haul off old unit and old parts - clean work area and test work for leaks and proper operation ** 9yr transferable/warranty on unit parts and labor ** 5yr warranty on all other work ** - bust tile up in guest shower around shower valve w a hammer. We are not liable for tile damage or repair ** customer will Redue shower at some point - cut out the old valve and cap hot and cold water lines. ** 5yr warranty **

- Replace 9yr old electric rheem w new premium state unit
 - replace all old connections to the unit.
 - install flood stop automatic shutoff valve ( battery powered ).
 - install electrical disconnect per code.
 - permit and inspection ( through the city of arlington )

- haul off old unit and old parts
- clean work area and test work for leaks and proper operation 

** 9yr transferable/warranty on unit parts and labor ** 5yr warranty on all other work **

- bust tile up in guest shower around shower valve w a hammer.

We are not liable for tile damage or repair ** customer will Redue shower at some point

- cut out the old valve and cap hot and cold water lines.

** 5yr warranty ** - Replace 9yr old electric rheem w new premium state unit
 - replace all old connections to the unit.
 - install flood stop automatic shutoff valve ( battery powered ).
 - install electrical disconnect per code.
 - permit and inspection ( through the city of arlington )

- haul off old unit and old parts
- clean work area and test work for leaks and proper operation 

** 9yr transferable/warranty on unit parts and labor ** 5yr warranty on all other work **

- bust tile up in guest shower around shower valve w a hammer.

We are not liable for tile damage or repair ** customer will Redue shower at some point

- cut out the old valve and cap hot and cold water lines.

** 5yr warranty **

Blake L.

Blake L. Job Checkin

Troubleshooting breaker and checked voltage coming into panel and breakers. found that there was an internally tripped tandem breaker and cut off and back on and everything worked with no issues. The problem happened during a storm. Also found that customer was making code and that 1 leg coming into panel had 130v on it when the coffee maker was running. Explained to customer she will need to have oncore out. Also explained that the breakers are outdated and need to be replaced due to age. If we have to come out for same problem we will automatically charge for a troubleshoot, including troubleshooting the meter base.

Troubleshooting breaker and checked voltage coming into panel and breakers. found that there was an internally tripped tandem breaker and cut off and back on and everything worked with no issues. The problem happened during a storm. Also found that customer was making code and that 1 leg coming into panel had 130v on it when the coffee maker was running. Explained to customer she will need to have oncore out. Also explained that the breakers are outdated and need to be replaced due to age. If we have to come out for same problem we will automatically charge for a troubleshoot, including troubleshooting the meter base. Troubleshooting breaker and checked voltage coming into panel and breakers. found that there was an internally tripped tandem breaker and cut off and back on and everything worked with no issues. The problem happened during a storm. Also found that customer was making code and that 1 leg coming into panel had 130v on it when the coffee maker was running. Explained to customer she will need to have oncore out. Also explained that the breakers are outdated and need to be replaced due to age. If we have to come out for same problem we will automatically charge for a troubleshoot, including troubleshooting the meter base.

James A.

James A. Job Checkin

Remove and dispose of existing tank water heater in attic. Install professional grade tank water heater. Replace water shutoff and supply lines. Replace emergency pan and reconnect to existing pan drain. Reconnect to existing exhaust pipe and t&p discharge piping. Install flood protection device. Provide city permit and inspection. Pull and reset wobbly toilet in master bathroom. Pulled and re set master bath toilet and ensured no rock or wobble. Applied sealant to base of toilet. Installed 50 gallon gas water heater in attic with flood stop device. 6 year warranty on parts and labor. Paid with card. Job complete.

Remove and dispose of existing tank water heater in attic. Install professional grade tank water heater. Replace water shutoff and supply lines. Replace emergency pan and reconnect to existing pan drain. Reconnect to existing exhaust pipe and t&p discharge piping. Install flood protection device. Provide city permit and inspection. Pull and reset wobbly toilet in master bathroom. 

Pulled and re set master bath toilet and ensured no rock or wobble. Applied sealant to base of toilet. Installed 50 gallon gas water heater in attic with flood stop device. 6 year warranty on parts and labor. Paid with card. Job complete. Remove and dispose of existing tank water heater in attic. Install professional grade tank water heater. Replace water shutoff and supply lines. Replace emergency pan and reconnect to existing pan drain. Reconnect to existing exhaust pipe and t&p discharge piping. Install flood protection device. Provide city permit and inspection. Pull and reset wobbly toilet in master bathroom. 

Pulled and re set master bath toilet and ensured no rock or wobble. Applied sealant to base of toilet. Installed 50 gallon gas water heater in attic with flood stop device. 6 year warranty on parts and labor. Paid with card. Job complete.

Rey V.

Rey V. Job Checkin

Arrived on the job site. The customer stated that he wanted to replace his FPE panel. Explained that when replacing a panel, a permit is required and all work must be brought up to current electrical code. The customer mentioned that he could not make a decision today, so we will follow up on Friday, November 14th, after 5:30 PM to discuss pricing with the supervisor. The customer was 100% happy and satisfied with today’s visit.

Arrived on the job site. The customer stated that he wanted to replace his FPE panel. Explained that when replacing a panel, a permit is required and all work must be brought up to current electrical code. The customer mentioned that he could not make a decision today, so we will follow up on Friday, November 14th, after 5:30 PM to discuss pricing with the supervisor. The customer was 100% happy and satisfied with today’s visit. Arrived on the job site. The customer stated that he wanted to replace his FPE panel. Explained that when replacing a panel, a permit is required and all work must be brought up to current electrical code. The customer mentioned that he could not make a decision today, so we will follow up on Friday, November 14th, after 5:30 PM to discuss pricing with the supervisor. The customer was 100% happy and satisfied with today’s visit.

James A.

James A. Job Checkin

Ran closet auger through toilet. Before starting work advised customer about existing scratches on porcelain. Toilet is currently flushing, but is making a gurgling sound, which indicates that a blockage is still present. Recommended pulling toilet and performing a camera inspection. No further work was authorized at this time.

Ran closet auger through toilet. Before starting work advised customer about existing scratches on porcelain. Toilet is currently flushing, but is making a gurgling sound, which indicates that a blockage is still present. Recommended pulling toilet and performing a camera inspection. No further work was authorized at this time. Ran closet auger through toilet. Before starting work advised customer about existing scratches on porcelain. Toilet is currently flushing, but is making a gurgling sound, which indicates that a blockage is still present. Recommended pulling toilet and performing a camera inspection. No further work was authorized at this time.

Tyler B.

Tyler B. Job Checkin

Arrived on the job site, and the customer stated that he is getting his front door replaced and remodeled. Upon inspection, I noticed a single-gang switch box located on the door trim that will need to be relocated. We will be moving the existing switch legs into a two-gang box and converting it into a four-gang box to accommodate the two new switch legs for the outdoor sconce lights and the front entry light. This is the full scope of work that will be completed when we return. The customer understands that we are not responsible for any sheetrock damage or sheetrock repair. All work, labor, and materials include a five-year warranty. The customer was 100% happy and satisfied with today’s visit. Removed existing two gang switch box in entry hall and installed a four gang box. Removed dougle switch and disconnected all wiring in box to make them dead. Performed troubleshoot to find hot for that box and removed it from circuit so the door framing can be safely removed. Dropped new

Arrived on the job site, and the customer stated that he is getting his front door replaced and remodeled. Upon inspection, I noticed a single-gang switch box located on the door trim that will need to be relocated. We will be moving the existing switch legs into a two-gang box and converting it into a four-gang box to accommodate the two new switch legs for the outdoor sconce lights and the front entry light.

This is the full scope of work that will be completed when we return. The customer understands that we are not responsible for any sheetrock damage or sheetrock repair. All work, labor, and materials include a five-year warranty. The customer was 100% happy and satisfied with today’s visit.

Removed existing two gang switch box in entry hall and installed a four gang box.  Removed dougle switch and disconnected all wiring in box to make them dead.  Performed troubleshoot to find hot for that box and removed it from circuit so the door framing can be safely removed.  Dropped new Arrived on the job site, and the customer stated that he is getting his front door replaced and remodeled. Upon inspection, I noticed a single-gang switch box located on the door trim that will need to be relocated. We will be moving the existing switch legs into a two-gang box and converting it into a four-gang box to accommodate the two new switch legs for the outdoor sconce lights and the front entry light.

This is the full scope of work that will be completed when we return. The customer understands that we are not responsible for any sheetrock damage or sheetrock repair. All work, labor, and materials include a five-year warranty. The customer was 100% happy and satisfied with today’s visit.

Removed existing two gang switch box in entry hall and installed a four gang box.  Removed dougle switch and disconnected all wiring in box to make them dead.  Performed troubleshoot to find hot for that box and removed it from circuit so the door framing can be safely removed.  Dropped new

Alex C.

Alex C. Job Checkin

Received pass report from city and emailed copy to the homeowner.

Received pass report from city and emailed copy to the homeowner. Received pass report from city and emailed copy to the homeowner.

Alex C.

Alex C. Job Checkin

Received pass report from city and emailed copy to homeowner.

Received pass report from city and emailed copy to homeowner. Received pass report from city and emailed copy to homeowner.

Alex C.

Alex C. Job Checkin

Attempted to reach homeowner through phone call but did not receive answer nor could I leave a voicemail. Sent message on the chat as that is how the customer has been communicating. Left message informing him that the pro source crew will be arriving today in the 12-1 window to remove the caution tape and forms.

Attempted to reach homeowner through phone call but did not receive answer nor could I leave a voicemail. Sent message on the chat as that is how the customer has been communicating. Left message informing him that the pro source crew will be arriving today in the 12-1 window to remove the caution tape and forms.

Alex C.

Alex C. Job Checkin

Home owner met inspector onsite and passed the final inspection.

Home owner met inspector onsite and passed the final inspection. Home owner met inspector onsite and passed the final inspection.

Daniel S.

Daniel S. Job Checkin

Warranty on flood stop. Flood stop was closed. Opened flood stop amd restored hot water to home. Job complete.


Johnathan P.

Johnathan P. Job Checkin

- Replace whole home shutoff and prv due to leak condition of parts. - excavate area and expose all piping and fittings in ground. - install all new piping / fittings in area. - replace old shutoff and flex line on cold side of water heater. - install 2gal expansion tank per code. - install new prv and whole home shutoff ( half turn ). - install new valve box and p gravel. - backfill hole and clean up. - test work and check for leaks. ** 5yr warranty on work **

- Replace whole home shutoff and prv due to leak condition of parts.
 - excavate area and expose all piping and fittings in ground.
 - install all new piping / fittings in area.
 - replace old shutoff and flex line on cold side of water heater.
 - install 2gal expansion tank per code.
 - install new prv and whole home shutoff ( half turn ).
 - install new valve box and p gravel.
 - backfill hole and clean up.
 - test work and check for leaks.

** 5yr warranty on work ** - Replace whole home shutoff and prv due to leak condition of parts.
 - excavate area and expose all piping and fittings in ground.
 - install all new piping / fittings in area.
 - replace old shutoff and flex line on cold side of water heater.
 - install 2gal expansion tank per code.
 - install new prv and whole home shutoff ( half turn ).
 - install new valve box and p gravel.
 - backfill hole and clean up.
 - test work and check for leaks.

** 5yr warranty on work **

James A.

James A. Job Checkin

Cut wall behind water heater and perform in wall plumbing inspection. Not responsible for wall repairs. Locate , cut, test and reassemble up to three hot water manifolds. Cap off compromised line on both ends. Install new water line through attic and walls as needed. Cut wall and ceiling materials as needed(not responsible for repairs. Provide city permit and inspection. Replace ball valve and supply line on water heater. Dig up yard line and install PRV (pressure reducing valve) to bring the pressure to safe levels along with a new 1/4 turn ball valve. 5 year warranty on parts and labor. It’s all pressure reducing valve and whole home shut off and customers flower bed in front yard. Installed expansion tank on customers water heater in hall closet. Rerouted three-quarter of work today. Hot water line from a hot water heater. To guest bathroom vanity. Strapped and insulated new piping through attic. Re built hot water manifolds to accept new pex hot water line. 5 year warranty

Cut wall behind water heater and perform in wall plumbing inspection. Not responsible for wall repairs. 
Locate , cut, test and reassemble up to three hot water manifolds.
Cap off compromised line on both ends. 
Install new water line through attic and walls as needed. 
Cut wall and ceiling materials as needed(not responsible for repairs. 
Provide city permit and inspection. 
Replace ball valve and supply line on water heater. 
Dig up yard line and install PRV (pressure reducing valve) to bring the pressure to safe levels along with a new 1/4 turn ball valve.
5 year warranty on parts and labor. 

It’s all pressure reducing valve and whole home shut off and customers flower bed in front yard. Installed expansion tank on customers water heater in hall closet.
Rerouted three-quarter of work today. Hot water line from a hot water heater. To guest bathroom vanity. Strapped and insulated new piping through attic. Re built hot water manifolds to accept new pex hot water line. 5 year warranty Cut wall behind water heater and perform in wall plumbing inspection. Not responsible for wall repairs. 
Locate , cut, test and reassemble up to three hot water manifolds.
Cap off compromised line on both ends. 
Install new water line through attic and walls as needed. 
Cut wall and ceiling materials as needed(not responsible for repairs. 
Provide city permit and inspection. 
Replace ball valve and supply line on water heater. 
Dig up yard line and install PRV (pressure reducing valve) to bring the pressure to safe levels along with a new 1/4 turn ball valve.
5 year warranty on parts and labor. 

It’s all pressure reducing valve and whole home shut off and customers flower bed in front yard. Installed expansion tank on customers water heater in hall closet.
Rerouted three-quarter of work today. Hot water line from a hot water heater. To guest bathroom vanity. Strapped and insulated new piping through attic. Re built hot water manifolds to accept new pex hot water line. 5 year warranty