Arrived to warranty the outlet at the top of the stairs as it lost power after an outlet was removed previously by us. Through investigation I found that the neutral behind the outlet around the corner had been capped off and the hot was left energizes. Rewired the back of the outlet box so the correct wires were capped off and the wires needed were energized. While there the homeowner also had two fandelier to install so I mounted those as well.
Arrived on site, and the customer requested to have the electrical panel relabeled and a new four-way switch installed for the hallway entry lights. The switches control the hallway lighting from three locations — the front entry near the main door, the garage entry on the left side, and the hallway leading into the kitchen. Verified that everything is functioning properly. The customer was informed that the work includes a five-year transferable warranty. Customer is 100% happy and satisfied with today’s visit.
Troubleshooting outdoor/ garage/ bathroom circuits and replacing plugs with new covers due to gfci in garage tripping any time you reset. Found that the backyard plug was wet inside the box so dried it up the best I could and replaced the plug. Replaced the front door plug and also had to clean up the garage gfci box and replace gfci. Install bubble covers and siliconed boxes and explained how everything works and explained that Christmas/ Halloween lights and decorations with open connections will make the gfci trip. Explained 5 year warr Only on garage gfci, front and back door plug. The circuit is also part of bathroom plugs. Return this Thursday after 6 to go over different options with wife Angela and husband Justin with updating electric panel. Return for warranty found that the recently installed gfci had a manufacturer defect so that the outlet itself had an open neutral connection but was able to operate the circuit with no issues. Replaced the device and verified the ne
Arrived onsite to potential warranty after homeowner had power outage and was concerned the whole house surge and multiple breakers were not operational. The whole house surge was still operating upon arrival but there were tripped breaker. Checked voltage and operation of the breakers and only one breaker has a broken trip indicator but it is operating. The only thing not operating in the home is a light kit on the downstairs bedroom fan. Homeowner is going to get replacement for light kit and replacement for the one breaker.
- Attempt drain restore through bath tub overflow ( bathroom above garage ) ** no warranty ** Successfully restored flow to bath tub and toilet , tested multiple times and homeowner wanted the water drain. Preformed safety check on plumbing system the only issues / problems I noticed were the water heaters are past there life expectancy and also that all the shutoff valves were push pull did let customer know he declined estimates at this time.
Warranty- Upon arrival customer mentioned he’s had elevated water bill since the repair we made a few months back. Verified that no leaks are present when sprinkler system is off. Ran several zones on sprinkler system and found two zones to have issues near area of yard in question. Advised customer to have sprinkler company come back and further troubleshoot and repair issues.
1. Extend circuit up for tv plug 2. Disconnect plug for other tv 3. Relocate and rewire switches upstairs (fan, fan lights, can light) 4. Install digital timer for front pond pumps 5. Minor troubleshoot on 3-way dimmer upstairs Removed two switches in upstairs living space and relocated up into 3 switch gang box and put recessed lights, fan, and chandeliers on their own switch. Installed new outlet for tv upstairs, and demoed old outlet. Replaced dimmer for wall sconces upstairs in living area, and removed dimmer from media room on same three way set up. Installed in wall timer switch under panel and out front yard water pond pump to come on at specific times.
Replaced both outside flood lights and added boxes all customer supplied. Customer did not have right bulbs so we used 1 bulb to test both lights . Left lights at settings customer requested. Also went over electrical evaluation with him. Customer was 100% happy and satisfied with todays service.
Arrived on job site customer stated that her car charger was overheating and indicating an error code. Let customer know that the type one charger is not a long-term solution and she would need to upgrade to a type two however I noticed that the breaker was a 60 amp CH2 pole breaker and the outlet that supports the car charger is a Nema 1450 car charger outlet which can only hold up to 50 A which the 60 amp breakers oversize. Ended up replacing the 60 amp breaker with a 50 amp GFCI to pole breaker customer has a five-year warranty on the breaker and also if she does sell the house it does transfer to the new homebuyers. Customer is 100% happy and satisfied with today’s visit.
1. Install jellyfish lighting 2. Install plug in eve 3. Install plug below tv 4. Install whole home surge protection 5. Install 22 arc fault breakers and gfci breakers 7. Install plug outside for uplights 8. Fix floor plug 9. Install large recessed box behind tv Monday/ all day
Install dedicated 240 volt 60 amp circuit under right side main electric panel in garage, install customer supplied hardwired wall mount EV charger
Replace front porch pendant light with new customer supplied light, supply and install 3 new RAB bullet lights on front of home