7415 Whitehall St. #119
Richland Hills, TX 76118
682-262-5759

Local Reviews
for north richland hills, tx

Rated 5.0 out of 5 stars based on 3 customer reviews

Excellent Service!

Blaike was extremely nice, professional, and very informative!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service with thorough explanations

Rey took his time and did a great job of explaining all the options. Then had Hector and Matthew come back and fix/replace all of items that I needed done. Both installers were very polite and thorough also.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

The tech did a great job. He was very thorough and gave me all the quotes I needed. I highly recommend!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for north richland hills, tx

Tyler B.

Tyler B. Job Checkin

Friday we are going to install a generator inlet and interlock with wiring from panel to inlet as well as install breaker for generator at panel Not supplying generator or generator cable Not supplying generator or generator cable Ran dedicated 30 amp circuit from panel to back corner of the house and installed generator inlet outlet, and installed interlock kit on panel.

Friday we are going to install a generator inlet and interlock with wiring from panel to inlet as well as install breaker for generator at panel 
Not supplying generator or generator cable


Not supplying generator or generator cable

Ran dedicated 30 amp circuit from panel to back corner of the house and installed generator inlet outlet, and installed interlock kit on panel. Friday we are going to install a generator inlet and interlock with wiring from panel to inlet as well as install breaker for generator at panel 
Not supplying generator or generator cable


Not supplying generator or generator cable

Ran dedicated 30 amp circuit from panel to back corner of the house and installed generator inlet outlet, and installed interlock kit on panel.

Blake L.

Blake L. Job Checkin

Customers are just now moving into the house and had a hole in the wall where range would typically go. I said live wire. Did not find any live wire in the hole. Left different options of getting different areas taken care of. I’m calling customer back next Wednesday around 12

Customers are just now moving into the house and had a hole in the wall where range would typically go. I said live wire. Did not find any live wire in the hole. Left different options of getting different areas taken care of. I’m calling customer back next Wednesday around 12 Customers are just now moving into the house and had a hole in the wall where range would typically go. I said live wire. Did not find any live wire in the hole. Left different options of getting different areas taken care of. I’m calling customer back next Wednesday around 12

Blake L.

Blake L. Job Checkin

Replaced bad dual function breaker controlling circuit 29. Customer was stating it was randomly tripping and explained to her that all the gen 2 breakers will go bad due to manufacturer defect. Showed her that there’s one more left controlling dishwasher and explained that will go bad and recommended replacing. Tested my breaker I replaced and everything worked with no issues and 5 year warranty on breaker.

Replaced bad dual function breaker controlling circuit 29. Customer was stating it was randomly tripping and explained to her that all the gen 2 breakers will go bad due to manufacturer defect. Showed her that there’s one more left controlling dishwasher and explained that will go bad and recommended replacing. Tested my breaker I replaced and everything worked with no issues and 5 year warranty on breaker. Replaced bad dual function breaker controlling circuit 29. Customer was stating it was randomly tripping and explained to her that all the gen 2 breakers will go bad due to manufacturer defect. Showed her that there’s one more left controlling dishwasher and explained that will go bad and recommended replacing. Tested my breaker I replaced and everything worked with no issues and 5 year warranty on breaker.

Tyler B.

Tyler B. Job Checkin

Arrived on site and spoke with the customer, who requested a dedicated circuit to be run for an exhaust fan/heater/light combo switch. We will also be installing and wiring a four-gang Leviton switch. Tyler will be returning to complete the work. The customer understands that all labor is covered under a five-year warranty, excluding any customer-supplied materials. The customer is fully satisfied with today’s visit. Ran dedicated 20 amp circuit from panel to master bathroom and installed specialty fan switch in new switch bank location. Ran two switchlegs from new switch location and ran to bath fan, turned power on everything working properly.

Arrived on site and spoke with the customer, who requested a dedicated circuit to be run for an exhaust fan/heater/light combo switch. We will also be installing and wiring a four-gang Leviton switch. Tyler will be returning to complete the work. The customer understands that all labor is covered under a five-year warranty, excluding any customer-supplied materials. The customer is fully satisfied with today’s visit.

Ran dedicated 20 amp circuit from panel to master bathroom and installed specialty fan switch in new switch bank location. Ran two switchlegs from new switch location and ran to bath fan, turned power on everything working properly.  Arrived on site and spoke with the customer, who requested a dedicated circuit to be run for an exhaust fan/heater/light combo switch. We will also be installing and wiring a four-gang Leviton switch. Tyler will be returning to complete the work. The customer understands that all labor is covered under a five-year warranty, excluding any customer-supplied materials. The customer is fully satisfied with today’s visit.

Ran dedicated 20 amp circuit from panel to master bathroom and installed specialty fan switch in new switch bank location. Ran two switchlegs from new switch location and ran to bath fan, turned power on everything working properly.

Rey V.

Rey V. Job Checkin

Arrived on the job site and the customer stated that the timer for the Eve outlets was not working properly. Upon inspection, I confirmed the timer was receiving power, but it was not sending power out to the load side. Performed a full troubleshoot, removed the timer, and temporarily bypassed it. All Christmas lights turned on, confirming the issue was either with the timer itself or its installation. I also noticed the circuit was not GFCI protected. I provided pricing and then installed a 2-gang cut-in box, added a GFCI outlet to properly protect the circuit, and rewired the timer. Everything is now operating correctly. Additionally, I replaced the GFCI by the outdoor kitchen in the backyard, which is functioning properly. I also replaced the two-pole 50-amp breaker for the oven in the main panel. The original breaker was a Cutler-Hammer BR; it was replaced with a Siemens 50-amp breaker, which is UL-listed and appropriate for the Siemens panel. All work performed—excluding the ti

Arrived on the job site and the customer stated that the timer for the Eve outlets was not working properly. Upon inspection, I confirmed the timer was receiving power, but it was not sending power out to the load side. Performed a full troubleshoot, removed the timer, and temporarily bypassed it. All Christmas lights turned on, confirming the issue was either with the timer itself or its installation.

I also noticed the circuit was not GFCI protected. I provided pricing and then installed a 2-gang cut-in box, added a GFCI outlet to properly protect the circuit, and rewired the timer. Everything is now operating correctly. Additionally, I replaced the GFCI by the outdoor kitchen in the backyard, which is functioning properly.

I also replaced the two-pole 50-amp breaker for the oven in the main panel. The original breaker was a Cutler-Hammer BR; it was replaced with a Siemens 50-amp breaker, which is UL-listed and appropriate for the Siemens panel.

All work performed—excluding the ti Arrived on the job site and the customer stated that the timer for the Eve outlets was not working properly. Upon inspection, I confirmed the timer was receiving power, but it was not sending power out to the load side. Performed a full troubleshoot, removed the timer, and temporarily bypassed it. All Christmas lights turned on, confirming the issue was either with the timer itself or its installation.

I also noticed the circuit was not GFCI protected. I provided pricing and then installed a 2-gang cut-in box, added a GFCI outlet to properly protect the circuit, and rewired the timer. Everything is now operating correctly. Additionally, I replaced the GFCI by the outdoor kitchen in the backyard, which is functioning properly.

I also replaced the two-pole 50-amp breaker for the oven in the main panel. The original breaker was a Cutler-Hammer BR; it was replaced with a Siemens 50-amp breaker, which is UL-listed and appropriate for the Siemens panel.

All work performed—excluding the ti

Rey V.

Rey V. Job Checkin

Arrived on the job site and the customer explained that an outlet in the master bedroom had made contact with the metal bed frame, causing a spark and damaging the outlet. We replaced the duplex outlet in the bedroom and verified that everything was working properly. I informed the customer that the outlet comes with a 5-year warranty. During the electrical safety inspection, I identified a few outdated or non-compliant items, including the smoke detectors, surge protection, and the existing 120V car charger, which should be upgraded to a 240V NEMA 14-50 plug. The customer would like some time to consider the additional work, and we will follow up next Friday to discuss pricing. The customer was 100% satisfied with today’s visit.

Arrived on the job site and the customer explained that an outlet in the master bedroom had made contact with the metal bed frame, causing a spark and damaging the outlet. We replaced the duplex outlet in the bedroom and verified that everything was working properly. I informed the customer that the outlet comes with a 5-year warranty.

During the electrical safety inspection, I identified a few outdated or non-compliant items, including the smoke detectors, surge protection, and the existing 120V car charger, which should be upgraded to a 240V NEMA 14-50 plug. The customer would like some time to consider the additional work, and we will follow up next Friday to discuss pricing. The customer was 100% satisfied with today’s visit. Arrived on the job site and the customer explained that an outlet in the master bedroom had made contact with the metal bed frame, causing a spark and damaging the outlet. We replaced the duplex outlet in the bedroom and verified that everything was working properly. I informed the customer that the outlet comes with a 5-year warranty.

During the electrical safety inspection, I identified a few outdated or non-compliant items, including the smoke detectors, surge protection, and the existing 120V car charger, which should be upgraded to a 240V NEMA 14-50 plug. The customer would like some time to consider the additional work, and we will follow up next Friday to discuss pricing. The customer was 100% satisfied with today’s visit.

Hector G.

Hector G. Job Checkin

1. Run wire from sub panel to bathroom 2. Install customer supplied breaker and cut in 3. Install plug in bath 4. Run wire from sub panel to bathroom 5. Install customer supplied breaker and cut in 6. Install plug in bath

1. Run wire from sub panel to bathroom 
2. Install customer supplied breaker and cut in 
3. Install plug in bath 
4. Run wire from sub panel to bathroom 
5. Install customer supplied breaker and cut in 
6. Install plug in bath 1. Run wire from sub panel to bathroom 
2. Install customer supplied breaker and cut in 
3. Install plug in bath 
4. Run wire from sub panel to bathroom 
5. Install customer supplied breaker and cut in 
6. Install plug in bath

Johnathan P.

Johnathan P. Job Checkin

- attempt to restore flow to main drain due to complete blockage in yard. - Preform camera inspection on main sewer piping from home to street to check condition and any issues in piping. ** estimates will be given for any issues found ** Did find issue in yard line and explained the repair needed , customer does want to get another quote to compare. Quotes are good for 30 days.

- attempt to restore flow to main drain due to complete blockage in yard.
- Preform camera inspection on main sewer piping from home to street to check condition and any issues in piping.

** estimates will be given for any issues found **

Did find issue in yard line and explained the repair needed , customer does want to get another quote to compare.

Quotes are good for 30 days. - attempt to restore flow to main drain due to complete blockage in yard.
- Preform camera inspection on main sewer piping from home to street to check condition and any issues in piping.

** estimates will be given for any issues found **

Did find issue in yard line and explained the repair needed , customer does want to get another quote to compare.

Quotes are good for 30 days.

Marco B.

Marco B. Job Checkin

Will not be responsible for bus or stud bar snapping due to age of panel, when replacing main breaker. If problem happens then we will still charge for a minor troubleshoot and price will change based on what is required for replacing panel. This price is only for replacing main breaker.

Will not be responsible for bus or stud bar snapping due to age of panel, when replacing main breaker. If problem happens then we will still charge for a minor troubleshoot and price will change based on what is required for replacing panel. This price is only for replacing main breaker. Will not be responsible for bus or stud bar snapping due to age of panel, when replacing main breaker. If problem happens then we will still charge for a minor troubleshoot and price will change based on what is required for replacing panel. This price is only for replacing main breaker.

Marco B.

Marco B. Job Checkin

Arrived on the job site. The customer stated that he wanted to add two Ethernet cable lines—one for the master bedroom and one for the work office—with the main double-port connection located behind the living room TV. Also replaced the existing doorbell with a hardwired Ring doorbell and performed a minor troubleshoot to wire the Cat 6 cable to the customer’s connections and plates. Replaced the customer-supplied doorbell chime. Replaced the broken outdoor uplight using the customer’s fixture. Replaced all smoke detectors in the home, a total of eight: four carbon monoxide/smoke combination detectors with sealed 10-year batteries, and four hardwired smoke detectors with sealed 10-year batteries. All smoke detectors include a 10-year warranty. Also replaced two dual-function breakers that were on recall; the customer supplied the breakers and these were the last two needing replacement. Everything installed today includes a 5-year warranty, except for the smoke detectors, which carry

Arrived on the job site. The customer stated that he wanted to add two Ethernet cable lines—one for the master bedroom and one for the work office—with the main double-port connection located behind the living room TV. Also replaced the existing doorbell with a hardwired Ring doorbell and performed a minor troubleshoot to wire the Cat 6 cable to the customer’s connections and plates. Replaced the customer-supplied doorbell chime. Replaced the broken outdoor uplight using the customer’s fixture. Replaced all smoke detectors in the home, a total of eight: four carbon monoxide/smoke combination detectors with sealed 10-year batteries, and four hardwired smoke detectors with sealed 10-year batteries. All smoke detectors include a 10-year warranty. Also replaced two dual-function breakers that were on recall; the customer supplied the breakers and these were the last two needing replacement.

Everything installed today includes a 5-year warranty, except for the smoke detectors, which carry Arrived on the job site. The customer stated that he wanted to add two Ethernet cable lines—one for the master bedroom and one for the work office—with the main double-port connection located behind the living room TV. Also replaced the existing doorbell with a hardwired Ring doorbell and performed a minor troubleshoot to wire the Cat 6 cable to the customer’s connections and plates. Replaced the customer-supplied doorbell chime. Replaced the broken outdoor uplight using the customer’s fixture. Replaced all smoke detectors in the home, a total of eight: four carbon monoxide/smoke combination detectors with sealed 10-year batteries, and four hardwired smoke detectors with sealed 10-year batteries. All smoke detectors include a 10-year warranty. Also replaced two dual-function breakers that were on recall; the customer supplied the breakers and these were the last two needing replacement.

Everything installed today includes a 5-year warranty, except for the smoke detectors, which carry

Rey V.

Rey V. Job Checkin

Arrived on the job site, and the customer stated that several lights throughout the home were flickering intermittently. Performed a full troubleshooting inspection, checking voltage at the panel as well as inside the meter base. All readings were normal, and there was no voltage imbalance. Informed the customer that the first step will be to have Oncore come out to check for any loose connections on their end, since the issue is intermittent. If the flickering continues and oncore confirms everything is fine on their side, the next step will likely be to replace the main panel and upgrade the grounding system, including pulling a permit and ensuring the work passes city inspection. Also replaced the GFCI and bubble cover on the back patio. Everything is working properly. The customer has a five-year warranty on the GFCI and connections. Customer is 100% happy and satisfied with today’s visit.

Arrived on the job site, and the customer stated that several lights throughout the home were flickering intermittently. Performed a full troubleshooting inspection, checking voltage at the panel as well as inside the meter base. All readings were normal, and there was no voltage imbalance. Informed the customer that the first step will be to have Oncore come out to check for any loose connections on their end, since the issue is intermittent. If the flickering continues and oncore confirms everything is fine on their side, the next step will likely be to replace the main panel and upgrade the grounding system, including pulling a permit and ensuring the work passes city inspection.

Also replaced the GFCI and bubble cover on the back patio. Everything is working properly. The customer has a five-year warranty on the GFCI and connections. Customer is 100% happy and satisfied with today’s visit. Arrived on the job site, and the customer stated that several lights throughout the home were flickering intermittently. Performed a full troubleshooting inspection, checking voltage at the panel as well as inside the meter base. All readings were normal, and there was no voltage imbalance. Informed the customer that the first step will be to have Oncore come out to check for any loose connections on their end, since the issue is intermittent. If the flickering continues and oncore confirms everything is fine on their side, the next step will likely be to replace the main panel and upgrade the grounding system, including pulling a permit and ensuring the work passes city inspection.

Also replaced the GFCI and bubble cover on the back patio. Everything is working properly. The customer has a five-year warranty on the GFCI and connections. Customer is 100% happy and satisfied with today’s visit.

Blake L.

Blake L. Job Checkin

Customer had a tripped art fall breaker and side panel and explain how to test and reset breaker. The original issue was that the nursery room was not working and had no power from plugs or switches. Explain to customer that the breaker trip for a reason, reset breaker and everything worked other than closet light. And realized that the breaker tripped every time you cut the light on. Took down light fixture and opened up switch and saw that there was a ground wire, touching a hot wire on the switch, causing the breaker to trip. Repaired switch and light fixture and everything worked with no issues. Explain to customer that she had two majorly oversized circuit breakers in the electrical panel with the wrong type breaker made from home line. Explain it is a BR panel and that a 30 amp breaker should not be on a 14 gauge wire.

Customer had a tripped art fall breaker and side panel and explain how to test and reset breaker. The original issue was that the nursery room was not working and had no power from plugs or switches. Explain to customer that the breaker trip for a reason, reset breaker and everything worked other than closet light. And realized that the breaker tripped every time you cut the light on. Took down light fixture and opened up switch and saw that there was a ground wire, touching a hot wire on the switch, causing the breaker to trip. Repaired switch and light fixture and everything worked with no issues. Explain to customer that she had two majorly oversized circuit breakers in the electrical panel with the wrong type breaker made from home line. Explain it is a BR panel and that a 30 amp breaker should not be on a 14 gauge wire. Customer had a tripped art fall breaker and side panel and explain how to test and reset breaker. The original issue was that the nursery room was not working and had no power from plugs or switches. Explain to customer that the breaker trip for a reason, reset breaker and everything worked other than closet light. And realized that the breaker tripped every time you cut the light on. Took down light fixture and opened up switch and saw that there was a ground wire, touching a hot wire on the switch, causing the breaker to trip. Repaired switch and light fixture and everything worked with no issues. Explain to customer that she had two majorly oversized circuit breakers in the electrical panel with the wrong type breaker made from home line. Explain it is a BR panel and that a 30 amp breaker should not be on a 14 gauge wire.

Marco B.

Marco B. Job Checkin

Arrived on the job site and the customer stated that he wanted two outdoor outlets replaced. I replaced both outlets, installed the customer-supplied bubble covers, and applied silicone around everything. I also informed the customer that the outlets and connections come with a five-year warranty, but the bubble covers are not covered. Performed a full safety evaluation throughout the home and noted that many components are approximately 39 years old and showing normal wear and tear. Provided solutions for replacing the main breaker panel, re-devicing, and bringing everything up to current electrical code. The customer stated that he would like some time to think about the recommendations and will call back when ready to move forward. Customer is 100% happy and satisfied with today’s visit.

Arrived on the job site and the customer stated that he wanted two outdoor outlets replaced. I replaced both outlets, installed the customer-supplied bubble covers, and applied silicone around everything. I also informed the customer that the outlets and connections come with a five-year warranty, but the bubble covers are not covered.

Performed a full safety evaluation throughout the home and noted that many components are approximately 39 years old and showing normal wear and tear. Provided solutions for replacing the main breaker panel, re-devicing, and bringing everything up to current electrical code.

The customer stated that he would like some time to think about the recommendations and will call back when ready to move forward. Customer is 100% happy and satisfied with today’s visit. Arrived on the job site and the customer stated that he wanted two outdoor outlets replaced. I replaced both outlets, installed the customer-supplied bubble covers, and applied silicone around everything. I also informed the customer that the outlets and connections come with a five-year warranty, but the bubble covers are not covered.

Performed a full safety evaluation throughout the home and noted that many components are approximately 39 years old and showing normal wear and tear. Provided solutions for replacing the main breaker panel, re-devicing, and bringing everything up to current electrical code.

The customer stated that he would like some time to think about the recommendations and will call back when ready to move forward. Customer is 100% happy and satisfied with today’s visit.

Marco B.

Marco B. Job Checkin

Customer needed a quote on replacing electrical panel fpe due to it being a hazard. Explained to son who was translating to father about why we have to do everything when replacing the panel. Customer is going to make sure insurance will accept our brand of panel and explained they will 100%. Call back- tomorrow afternoon

Customer needed a quote on replacing electrical panel fpe due to it being a hazard. Explained to son who was translating to father about why we have to do everything when replacing the panel. Customer is going to make sure insurance will accept our brand of panel and explained they will 100%. 

Call back- tomorrow afternoon Customer needed a quote on replacing electrical panel fpe due to it being a hazard. Explained to son who was translating to father about why we have to do everything when replacing the panel. Customer is going to make sure insurance will accept our brand of panel and explained they will 100%. 

Call back- tomorrow afternoon

Johnathan P.

Johnathan P. Job Checkin

- attempt to pop clog on main sewer line in yard. No warranty on cable - Preform camera inspection on main sewer yard line due to issue in drain. ** solutions will be given for any issues found ** Successfully popped clog with big sewer machine, however there is massive root build up from connection on pvc to clay pipe. located issue on side of home ( did let the customer know they can reach out to the city to see if the issue is on their side if not we made a estimate for repair )