7415 Whitehall St. #119
Richland Hills, TX 76118
682-262-5759

Local Reviews
for north richland hills, tx

Rated 5.0 out of 5 stars based on 2 customer reviews

Excellent service with thorough explanations

Rey took his time and did a great job of explaining all the options. Then had Hector and Matthew come back and fix/replace all of items that I needed done. Both installers were very polite and thorough also.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

The tech did a great job. He was very thorough and gave me all the quotes I needed. I highly recommend!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for north richland hills, tx

Johnathan P.

Johnathan P. Job Checkin

- attempt to pop clog on main sewer line in yard. No warranty on cable - Preform camera inspection on main sewer yard line due to issue in drain. ** solutions will be given for any issues found ** Successfully popped clog with big sewer machine, however there is massive root build up from connection on pvc to clay pipe. located issue on side of home ( did let the customer know they can reach out to the city to see if the issue is on their side if not we made a estimate for repair )


Rey V.

Rey V. Job Checkin

Arrived on the job site. The customer stated that multiple outlets in her restrooms were not working. Performed a troubleshooting service to diagnose the issue and found that two GFCI outlets—one in the hall bathroom and one in the master bathroom—were not wired properly. Replaced the GFCI in the master bath with a standard white Decora outlet, as it is already protected by the GFCI in the hall bath. Verified that all outlets are now working properly. While inspecting the electrical panel and checking breakers during the diagnostic, I noticed that the panel is outdated and approximately 40 years old. Offered the customer a quote for a panel replacement, but she declined for now and stated she would call back within a year to discuss pricing. The customer was 100% satisfied with today’s visit and understands that the replaced outlet in the master bath is covered by a five-year warranty.

Arrived on the job site. The customer stated that multiple outlets in her restrooms were not working. Performed a troubleshooting service to diagnose the issue and found that two GFCI outlets—one in the hall bathroom and one in the master bathroom—were not wired properly. Replaced the GFCI in the master bath with a standard white Decora outlet, as it is already protected by the GFCI in the hall bath. Verified that all outlets are now working properly.

While inspecting the electrical panel and checking breakers during the diagnostic, I noticed that the panel is outdated and approximately 40 years old. Offered the customer a quote for a panel replacement, but she declined for now and stated she would call back within a year to discuss pricing. The customer was 100% satisfied with today’s visit and understands that the replaced outlet in the master bath is covered by a five-year warranty. Arrived on the job site. The customer stated that multiple outlets in her restrooms were not working. Performed a troubleshooting service to diagnose the issue and found that two GFCI outlets—one in the hall bathroom and one in the master bathroom—were not wired properly. Replaced the GFCI in the master bath with a standard white Decora outlet, as it is already protected by the GFCI in the hall bath. Verified that all outlets are now working properly.

While inspecting the electrical panel and checking breakers during the diagnostic, I noticed that the panel is outdated and approximately 40 years old. Offered the customer a quote for a panel replacement, but she declined for now and stated she would call back within a year to discuss pricing. The customer was 100% satisfied with today’s visit and understands that the replaced outlet in the master bath is covered by a five-year warranty.

Marco B.

Marco B. Job Checkin

Arrived on the job site, and the customer stated that he was experiencing electrical issues throughout the home, including partial power loss. Upon inspection, it was determined that the customer was not receiving 240 volts due to a faulty electrical meter base. Provided a quote to replace the main breaker panel located outside, as well as the overhead meter base next to it. We will also be upgrading the electrical grounding system, including the ground rod and cold water bond, and installing a whole-home surge protector on the main panel. A city permit will be pulled to ensure all work passes inspection. The customer is enrolled in the VIP plan and will receive a 10% discount on electrical and plumbing services. We are scheduled to return on Tuesday, November 4th, to complete the work. The customer understands that all work and labor are covered by a five-year warranty, and the panel, meter base, and whole-home surge protector come with a lifetime warranty. The customer is 100% happy

Arrived on the job site, and the customer stated that he was experiencing electrical issues throughout the home, including partial power loss. Upon inspection, it was determined that the customer was not receiving 240 volts due to a faulty electrical meter base. Provided a quote to replace the main breaker panel located outside, as well as the overhead meter base next to it. We will also be upgrading the electrical grounding system, including the ground rod and cold water bond, and installing a whole-home surge protector on the main panel. A city permit will be pulled to ensure all work passes inspection.

The customer is enrolled in the VIP plan and will receive a 10% discount on electrical and plumbing services. We are scheduled to return on Tuesday, November 4th, to complete the work. The customer understands that all work and labor are covered by a five-year warranty, and the panel, meter base, and whole-home surge protector come with a lifetime warranty. The customer is 100% happy Arrived on the job site, and the customer stated that he was experiencing electrical issues throughout the home, including partial power loss. Upon inspection, it was determined that the customer was not receiving 240 volts due to a faulty electrical meter base. Provided a quote to replace the main breaker panel located outside, as well as the overhead meter base next to it. We will also be upgrading the electrical grounding system, including the ground rod and cold water bond, and installing a whole-home surge protector on the main panel. A city permit will be pulled to ensure all work passes inspection.

The customer is enrolled in the VIP plan and will receive a 10% discount on electrical and plumbing services. We are scheduled to return on Tuesday, November 4th, to complete the work. The customer understands that all work and labor are covered by a five-year warranty, and the panel, meter base, and whole-home surge protector come with a lifetime warranty. The customer is 100% happy

Rey V.

Rey V. Job Checkin

Arrived on site. The customer stated that he wanted to replace an uplight knuckle fixture on the exterior of the home, replace an exhaust fan/light combo in the upstairs restroom, and install a dimmer switch to control the vanity lights in the same restroom. Performed a full home safety evaluation and noted several concerns and code violations, including missing arc-fault protection throughout the home, no whole-home surge protection, outdated smoke detectors, and backstabbed devices. Provided solutions and repair options, as well as a step-by-step plan to address the code violations. The customer requested time to review the quotes and will call back to proceed with the work. Hector will be completing the installations today for the exhaust fan/light combo, the exterior uplight fixture, and the dimmer switch. The customer understands that there is a five-year warranty on all labor and materials, including the exhaust fan and exterior fixture. The dimmer switch itself is customer-su

Arrived on site. The customer stated that he wanted to replace an uplight knuckle fixture on the exterior of the home, replace an exhaust fan/light combo in the upstairs restroom, and install a dimmer switch to control the vanity lights in the same restroom.

Performed a full home safety evaluation and noted several concerns and code violations, including missing arc-fault protection throughout the home, no whole-home surge protection, outdated smoke detectors, and backstabbed devices.

Provided solutions and repair options, as well as a step-by-step plan to address the code violations. The customer requested time to review the quotes and will call back to proceed with the work.

Hector will be completing the installations today for the exhaust fan/light combo, the exterior uplight fixture, and the dimmer switch. The customer understands that there is a five-year warranty on all labor and materials, including the exhaust fan and exterior fixture. The dimmer switch itself is customer-su Arrived on site. The customer stated that he wanted to replace an uplight knuckle fixture on the exterior of the home, replace an exhaust fan/light combo in the upstairs restroom, and install a dimmer switch to control the vanity lights in the same restroom.

Performed a full home safety evaluation and noted several concerns and code violations, including missing arc-fault protection throughout the home, no whole-home surge protection, outdated smoke detectors, and backstabbed devices.

Provided solutions and repair options, as well as a step-by-step plan to address the code violations. The customer requested time to review the quotes and will call back to proceed with the work.

Hector will be completing the installations today for the exhaust fan/light combo, the exterior uplight fixture, and the dimmer switch. The customer understands that there is a five-year warranty on all labor and materials, including the exhaust fan and exterior fixture. The dimmer switch itself is customer-su

Rey V.

Rey V. Job Checkin

Arrived on the job site, and the customer stated that their AFCI breaker was consistently tripping. I offered to perform a full circuit troubleshoot, but the customer declined. During the safety evaluation, I noticed a wet spot on the ceiling near a 6-inch surface-mount light fixture. I informed the customer that this moisture could be contributing to the breaker tripping. The customer agreed to proceed with diagnosing and replacing the light fixture only. While replacing the fixture, I observed significant water damage on the old light. I inspected the connections and confirmed that the wiring and junction box were dry and free of water damage—the moisture was isolated to the fixture itself. After installing the new surface-mount light fixture and restoring power, the breaker remained on and everything operated properly. I informed the customer that the new fixture is covered by a five-year warranty. However, if the AFCI breaker trips again and it’s unrelated to the light fixture, a

Arrived on the job site, and the customer stated that their AFCI breaker was consistently tripping. I offered to perform a full circuit troubleshoot, but the customer declined. During the safety evaluation, I noticed a wet spot on the ceiling near a 6-inch surface-mount light fixture. I informed the customer that this moisture could be contributing to the breaker tripping. The customer agreed to proceed with diagnosing and replacing the light fixture only.

While replacing the fixture, I observed significant water damage on the old light. I inspected the connections and confirmed that the wiring and junction box were dry and free of water damage—the moisture was isolated to the fixture itself. After installing the new surface-mount light fixture and restoring power, the breaker remained on and everything operated properly.

I informed the customer that the new fixture is covered by a five-year warranty. However, if the AFCI breaker trips again and it’s unrelated to the light fixture, a Arrived on the job site, and the customer stated that their AFCI breaker was consistently tripping. I offered to perform a full circuit troubleshoot, but the customer declined. During the safety evaluation, I noticed a wet spot on the ceiling near a 6-inch surface-mount light fixture. I informed the customer that this moisture could be contributing to the breaker tripping. The customer agreed to proceed with diagnosing and replacing the light fixture only.

While replacing the fixture, I observed significant water damage on the old light. I inspected the connections and confirmed that the wiring and junction box were dry and free of water damage—the moisture was isolated to the fixture itself. After installing the new surface-mount light fixture and restoring power, the breaker remained on and everything operated properly.

I informed the customer that the new fixture is covered by a five-year warranty. However, if the AFCI breaker trips again and it’s unrelated to the light fixture, a

Rey V.

Rey V. Job Checkin

Arrived on job site; customer stated that the chandelier in the master restroom made a loud popping sound from the canopy area. Afterward, he noticed that the breaker had tripped. He reset the breaker, but the light still did not come back on. He then tried swapping the switches with no success and decided to call us out to diagnose the issue. Performed a minor troubleshooting service and found that the wiring above the fixture was burnt and melted. Discovered that there was no electrical box protecting the wire, so we installed a pancake box on the beam for proper support and protection. put the old chandelier, re-spliced the wiring, and verified that everything is now working properly. Offered to perform a full safety evaluation, but the customer declined. Noted that the electrical panel was replaced in March and that the home has been re-deviced as well with new grounding system , surge protection, smoke detectors, and GFCIs—all properly installed and in the correct locations. Cu

Arrived on job site; customer stated that the chandelier in the master restroom made a loud popping sound from the canopy area. Afterward, he noticed that the breaker had tripped. He reset the breaker, but the light still did not come back on. He then tried swapping the switches with no success and decided to call us out to diagnose the issue.

Performed a minor troubleshooting service and found that the wiring above the fixture was burnt and melted. Discovered that there was no electrical box protecting the wire, so we installed a pancake box on the beam for proper support and protection. put the old chandelier, re-spliced the wiring, and verified that everything is now working properly.

Offered to perform a full safety evaluation, but the customer declined. Noted that the electrical panel was replaced in March and that the home has been re-deviced as well with new grounding system , surge protection, smoke detectors, and GFCIs—all properly installed and in the correct locations.

Cu Arrived on job site; customer stated that the chandelier in the master restroom made a loud popping sound from the canopy area. Afterward, he noticed that the breaker had tripped. He reset the breaker, but the light still did not come back on. He then tried swapping the switches with no success and decided to call us out to diagnose the issue.

Performed a minor troubleshooting service and found that the wiring above the fixture was burnt and melted. Discovered that there was no electrical box protecting the wire, so we installed a pancake box on the beam for proper support and protection. put the old chandelier, re-spliced the wiring, and verified that everything is now working properly.

Offered to perform a full safety evaluation, but the customer declined. Noted that the electrical panel was replaced in March and that the home has been re-deviced as well with new grounding system , surge protection, smoke detectors, and GFCIs—all properly installed and in the correct locations.

Cu

James A.

James A. Job Checkin

Arrived on site to investigate quote for a sump pump install. Need to return Monday morning with field supervisor to further diagnose and quote job accurately.

Arrived on site to investigate quote for a sump pump install. Need to return Monday morning with field supervisor to further diagnose and quote job accurately. Arrived on site to investigate quote for a sump pump install. Need to return Monday morning with field supervisor to further diagnose and quote job accurately.

Johnathan P.

Johnathan P. Job Checkin

- drain down water heater all the way - replace drain valve on unit - fill back up and check work for leaks ** 5yr warranty on drain valve ** we are not liable for any existing plumbing ** Tested work no leaks and showed daughter how the new valve will work Cleaned up tool and trash

- drain down water heater all the way 

- replace drain valve on unit

- fill back up and check work for leaks

** 5yr warranty on drain valve ** we are not liable for any existing plumbing **

Tested work no leaks and showed daughter how the new valve will work

Cleaned up tool and trash - drain down water heater all the way 

- replace drain valve on unit

- fill back up and check work for leaks

** 5yr warranty on drain valve ** we are not liable for any existing plumbing **

Tested work no leaks and showed daughter how the new valve will work

Cleaned up tool and trash

Alex C.

Alex C. Job Checkin

Home owner met with inspector onsite after repairs had been made and passed the final inspection.

Home owner met with inspector onsite after repairs had been made and passed the final inspection. Home owner met with inspector onsite after repairs had been made and passed the final inspection.

Blake L.

Blake L. Job Checkin

Installed a customer supply and Tesla charger hardwired underneath Square D panel. Installed a classified 60 amp square D breaker at the top right. Check voltage on Tesla charger, torque screws and plugged into car and everything worked with no issues and the car is charging with no problems. Five year warranty on the items I supplied.

Installed a customer supply and Tesla charger hardwired underneath Square D panel. Installed a classified 60 amp square D breaker at the top right. Check voltage on Tesla charger, torque screws and plugged into car and everything worked with no issues and the car is charging with no problems. Five year warranty on the items I supplied. Installed a customer supply and Tesla charger hardwired underneath Square D panel. Installed a classified 60 amp square D breaker at the top right. Check voltage on Tesla charger, torque screws and plugged into car and everything worked with no issues and the car is charging with no problems. Five year warranty on the items I supplied.

Alex C.

Alex C. Job Checkin

Installed outlets


Johnathan P.

Johnathan P. Job Checkin

Shower valve replacement


Daniel S.

Daniel S. Job Checkin

Cleared drain line


Alex C.

Alex C. Job Checkin

Installed ceiling fans


Johnathan P.

Johnathan P. Job Checkin

Replace toilets in home