221 Technology Park Ln
Fuquay Varina, NC 27526
888-998-7772

Local Reviews
for angier, nc


Job Locations
for angier, nc

Jacob  S.

Jacob S. Job Checkin

Fire Suppression and Access Control Installation FS #1 Ansul R102 (3.0/3.0 gallon) - Wall Utility Cabinet Left - [covering 2 hoods] pull permits deliver gas valve perform final with AHJ submit for revision with harnett county PRE TEST


Jacob  S.

Jacob S. Job Checkin

Initial Services Performed: Semi-Annual Kitchen System Inspection Deficiencies Discovered: The existing Pyro-Chem Kitchen Knight II PCL 460 system cylinder is PAST DUE for the required 12 year hydrostatic testing. This cylinder is Department of Transportation (DOT) specified therefore requires serialization and testing in an approved testing center as per the DOT. The (1) eye burner needs nozzle protection Scope of Work Proposed: Perform a 12 year hydrostatic test and recharge on the existing cylinder in our DOT approved testing center using the proof of pressure testing method and equipment. Add nozzle protection to the (1) eye bburner. Exclusions: Electrical and /or Plumbing work (if required). Permits (if required). Any changes mandated as a result of an Authority Having Jurisdiction (AHJ) review of the proposed scope of work. Fire Suppression Repair Pyro Chem PCL 4.6 Gallon Hood Cabinet: Initial Services Performed: Semi-Annual Kitchen System Inspection Deficiencies Discovered


Jacob  S.

Jacob S. Job Checkin

Portable Extinguishers, Emergency / Exit Lights, and Fire Suppression Inspection Perform the Annual Portable Fire Extinguisher Inspection as per NFPA 10. Any maintenance services or new units required must be documented and customer authorization obtained before work can be performed. Perform the Annual Emergency/Exit Light Inspection (Quick Check) to each unit on-site. No certification label is to be applied for this type of inspection. Additional maintenance needed i.e.batteries and bulbs must have customer approval. Any units that require replacement must be documented as a deficiency and installed on an approved return trip, if same day approval is not obtained. Semi-Annual Kitchen Suppression System Inspection as per NFPA 17A. Fire Alarm system (if present) must be placed on test prior to performing service. Access to FACP for purpose of reset must be made available prior to conducting full function test. Paperwork must state "City Compliance Filing Fee" for inspection jobs Defic


Jacob  S.

Jacob S. Job Checkin

Fire Suppression Inspection Pyro Chem PCL 4.6 Gallon Hood Cabinet: Perform Kitchen System Inspection Must Collect Pay at Time of Service otherwise we can not perform services. See comments for what to charge. Confirm customer understands this in advance of arrival so you do not waster a trip Deficiency for Pyro Chem PCL 4.6 Gallon Hood Cabinet: (1) 4.6 gallon pyrochem tank due for 12 year hydrostatic testing.


Jacob  S.

Jacob S. Job Checkin

Tech Clock IN/OUT IVR 844-347-3487 806088 Portable Extinguishers Inspection Conduct annual inspection on all extinguishers throughout location as required per NFPA10 and any other applicable codes/standards (review all areas with site manager).


Jacob  S.

Jacob S. Job Checkin

Emergency / Exit Lights and Portable Extinguishers Inspection Perform the Annual Emergency/Exit Light Inspection (Quick Check) to each unit on-site. No certification label is to be applied for this type of inspection. Additional maintenance needed i.e.batteries and bulbs must have customer approval. Any units that require replacement must be documented as a deficiency and installed on an approved return trip, if same day approval is not obtained. Perform the Annual Portable Fire Extinguisher Inspection as per NFPA 10. Any maintenance services or new units required must be documented and customer authorization obtained before work can be performed.


Jacob  S.

Jacob S. Job Checkin

Fire Suppression Inspection Semi-Annual Kitchen Suppression System Inspection as per NFPA 17A. Fire Alarm system (if present) must be placed on test prior to performing service. Access to FACP for purpose of reset must be made available prior to conducting full function test.