Service Call: Commercial Overhead Door Issue: The rollers have come out of the track and the door will not open. Work Completed: The technician replaced the top bracket, two #2 rollers, two slide locks and installed two step plates. The technician lubricated all moving components on the door and cycled it for safe and proper operation.