253 Timberlane Dr
Pisgah Forest, NC 28768
828-483-4040

Local Reviews

Rated 5.0 out of 5 stars based on 250 customer reviews

Great service!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Great service. Friendly and knowledgeable. Amaya on time and completed the work quickly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great company

The technician was very knowledgeable and checked everything

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent as always

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Cameron is great. He’s always on time, texts to let me know when he’ll arrive. He’s personable, efficient and neat. Knows what he’s doing.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Kelsey was great. He was easy to ask questions of and very knowledgable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

Cameron was very kind and informative

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Comfort Central is the best -- always on time, giving clear notice when coming. Very professional, competent, trustworthy. And always friendly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quality cordial service

Jay arrived promptly this morning for our annual A/C tune up. He is a master technician and his service call was cordial, efficient, and thorough. He is also largely responsible for the installation and design (in collaboration with Kevin) of the A/C system in our 100-year-old home. That installation is a marvel of architecturally tasteful and effective cooling and dehumidification bordering on art.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service without question

Kept me informed of what they were doing and why. They explained everything in detail so that I could understand.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding as always

Cameron and Thomas were outstanding. They arrived on time and quickly and thoroughly made the checks on our system. I've used Comfort Central for years and would highly recommend their work. Thank you and Happy Easter.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Bi Annual service in preparation for summer

Both Cameron and Thomas were prompt on their arrival. Always professional in their appearance and demeanor. I received a full review of their testing and was satisfied with the results.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Cameron checked out our unit and got it running well and ready for AC use this winter. He also checked our thermostat and answered all my questions about how to use it most effectively. We appreciate the good service from Comfort Central.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Kelsey T.

Kelsey T. Job Checkin

System has a 26 degree temperature difference Indoor blower is pulling 1.3 amps Outdoor compressor at full capacity is pulling 7.2 amps Outdoor fan motor at full capacity is pulling 1.3 amps cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications System is excellent working condition.


Jay E.

Jay E. Job Checkin

2 Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Kelsey T.

Kelsey T. Job Checkin

System has a 25 degree temperature difference Indoor blower is pulling .8 amps Outdoor fan motor is pulling.65 amps Outdoor compressor is pulling 4.5 amps Outdoor capacitor is within manufacturer specifications. cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications System is in great shape and I see no issues or potential failures.


Cameron  S.

Cameron S. Job Checkin

Found heat pump breaker switched off, turned breaker on and cycled system to check operation in both heating and cooling. Everything appears to operate normally. Tested furnace, heat pump, and AC. Believe breaker got knocked accidentally during well work causing system to shut off.


Jay E.

Jay E. Job Checkin

Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Jay E.

Jay E. Job Checkin

cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Jay E.

Jay E. Job Checkin

cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Jay E.

Jay E. Job Checkin

cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Jay E.

Jay E. Job Checkin

Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Jay E.

Jay E. Job Checkin

Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Jay E.

Jay E. Job Checkin

cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Jay E.

Jay E. Job Checkin

Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Cameron  S.

Cameron S. Job Checkin

Found system outdoor TV has failed shut causing system pressures to rise and cut system off on high pressure. Recommend replacement of outdoor TV and filter drier. Will call with estimate for replacement of part.


Jay E.

Jay E. Job Checkin

cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Jay E.

Jay E. Job Checkin

Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.