253 Timberlane Dr
Pisgah Forest, NC 28768
828-483-4040

Local Reviews
for laurel park, nc

Rated 5.0 out of 5 stars based on 5 customer reviews

Excellent service

On time. Professional, friendly, efficient and knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding Service!

Cameron was extremely knowledgeable and spent the needed for a custom repair job and rebuild. I highly recommend him and his company!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent, friendly, knowledgeable service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

High Integrity Company

I really enjoyed working with Comfort Central. The owner, Kevin, was great, very personable, knowledgeable and trustworthy. I had two full systems and one AC unit added so it was a big project. Just an antidote on Kevin's knowledge, When I I asked one company how load the indoor unit of the Mitsubishi ductless system was he said "You will love it you can sleep in it." In contrast Kevin said 44 decibels. I really appreciated the factual answer rather than the 'sales' answer. Kevin's quote was thousands less. Originally they were doing a ductless system in on cottage and adding AC to another cottage and the main house. When dismantling the heating unit in the main house they showed me bad cracks and openings throughout the heat exchanger in the 20 year old furnace. Clearly it had to be replaced. I thought this is going to cost a bomb, they have me over a barrel and I will have to accept whatever they offer. Kevin I think did just the opposite and tried to give me the very best price he could because he knew my budget was tight. I really feel like I was not taken advantage of. Their work was prompt and look to be to a high standard. The systems (Maytag on the ducted systems and Mitsubishi on the ductless) seem excellent. Our inspector said everything was done right and to code with no issues or corner cutting. I highly recommend them especially if you are not an expert on H/VAC. Kevin is very knowledgeable and I believe you can trust what he tells you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for laurel park, nc

Cameron  S.

Cameron S. Job Checkin

Performed heating maintenance tune up service on heat pump system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, defrost. Cleared system drain lines. Everything looks and runs great! Filter will be due to be changed in the spring. Find filters at filterfetch.com using product code CKT-P4NY


Kelsey T.

Kelsey T. Job Checkin

serviced and inspected heat pump system, including electrical, safeties, controls, reversing valve and defrost cycle to manufacturer specifications. Blower motor is pulling 1 amp Heat strips are pulling 20 amps Heat strips temperature difference is 20 Heat pump temperature difference is 23 Defrost is working properly Compressor is pulling 4.4 amps Outdoor fan is pulling .5 amps Capacitor is within manufacturer specifications Customer said tree had fallen and pushed outdoor unit about 4 inches. Inspected linset up to line hide and inspected the coil. No kinks or major damage seem to of happened. System is currently working to manufacturer specifications.


Jay E.

Jay E. Job Checkin

Thermostat is bad out of the box. Have 24 volts at base plate. This is arzel tstat for hydronic control homeowner said he was gonna order another one if he can’t find it online and exact replacement he will give us a call so we can try to research it and find what he needs.


Cameron  S.

Cameron S. Job Checkin

Performed AC maintenance tune up service on both AC systems upstairs and downstairs found upstairs unit low on r410a refrigerant added 1.2lbs refrigerant and cycled to check operation. Cleaned coils and drains on both systems. Everything looks and runs great!


Cameron  S.

Cameron S. Job Checkin

Performed AC maintenance tune up service on straight AC system checking all electrical components, refrigerant balance, unit start up, operation, shut down, cleaning of indoor and outdoor coils, and treatment of drain line. Everything looks and runs great! No recommended changes at this time.


Kelsey T.

Kelsey T. Job Checkin

Performed spring maintenance on system. System is in excellent running condition Indoor blower amps is .9 Temperature difference between return and supply was 28 degrees. Outdoor compressor with system at full capacity was 7.1 amps and outdoor fan was 1 amp. Cleaned indoor and outdoor coil and vacuumed out condensate line. Looked over system due to strange noise complaint back in January during a rain storm, and could not find any signs of damage to system. If this problem happens again give us a call to come back out to look over system.


Jay E.

Jay E. Job Checkin

On arrival Thermostat was satisfied at 70. boiler seems to be running normal. Thermostat is in the hallway which would be warmer than any of the apartments. This particular apartment has two window units in it with a 2 inch gap. I explained to the tenants that they should probably plug the gaps which would allow the heat to stay in the apartment especially on more breezy days couldn’t find any issues other than the windows


Kelsey T.

Kelsey T. Job Checkin

System was working on arrival, checked temperature difference, return was 63 and supply was 102 giving a 39 degree temperature difference, blower amps was 3.2, inducer was pulling .5 amps cycled system off and on 7 times and was unable to get system to fail. As of right now system is operating properly.


Cameron  S.

Cameron S. Job Checkin

System operating on arrival, noted a couple issues with the duct work but assumed system worked before with the current duct design. Found gas pressure too high possibly causing unit to cycle on high limit switch, adjusted gas pressure down to 3.5 inches of water column on high and down to 2.7 on the low. Cycled system to check operation tested both low and high fires, system should be able to maintain and keep up to desired set point of 67-68°F


Jay E.

Jay E. Job Checkin

Found water on floor near back flow preventer. This would pop if city lost pressure to prevent the boiler water mixing with potable water. Boiler pressure is at 10 psi. I tested pressure relief valve. Which pops at 30 psi. Looked over all connections on boiler pipes. I didn’t see anything that was wet or dripping that would cause the issue of water on the floor.


Cameron  S.

Cameron S. Job Checkin

Found condenser fan motor has failed and must be replaced - replaced with rescue motor


Cameron  S.

Cameron S. Job Checkin

BOSCH HEAT PUMP - Insulated drain trap as it was condensingon outside of the drain. Cycled unit to check operation. Everything looks and runs great!


Jay E.

Jay E. Job Checkin

SEER2 20; HSPF2 9.5; EER2 13 Make: Bosch Model: BOVA36HDN1M20G Outdoor Unit BVA-24WN1-M20 Air Handler 10kw electric heat Honeywell T-6 Thermostat Tech Pure Merv 11 Media Filter 3/8” refrigerant line Installation shall include: Equipment specified above plus materials and labor to include: • We will install new return and supply plenums and rework near air handler duct work. • Required Electrical is included. • Permit Fee for Installation. • All work will be completed in a professional workmanlike manner. • Old equipment and trash from installation will be removed from premises. • Bosch Manufacturer’s Warranty: Ten (10) Year Limited Parts, including Compressor. • One (1) Year Labor Warranty Provided by Comfort Central, Inc.


Alex Andre S.

Alex Andre S. Job Checkin

Bleeding air out of radiators, boiler


Alex Andre S.

Alex Andre S. Job Checkin

Bleeding air out of radiators, boiler