They have taken care of our units for many years and would not use anyone else. Everyone is professional and friendly. A real pleasure. Camron is the best you could ask for.
Alex was professional, pleasant and through. Just what you want from a service provider. He explained everything that he had done to my wife and I in very understandable language. We highly recommend this company and Alex.
Found contractor on generator box pulled in but not allowing the 240 to go to air handler. Needs a electrician
We received a no heat service call from a customer whose propane furnace would not ignite. With a cold front moving into the area, this was an urgent issue. I performed a full diagnostic and, after confirming proper gas pressure, tested the furnace igniter and found it was faulty. I completed the propane furnace repair by replacing the bad furnace igniter with a new part from my van stock. The unit fired up immediately upon testing. The customer was relieved the issue was found so quickly and that their Rosman heating system was fully restored.
A family building a new addition to their home needed a complete furnace installation for the space. Because natural gas was not available, they chose a high-efficiency propane furnace. Our work involved calculating the heat load for the addition, running new ductwork, and installing the new heating system and a smart thermostat. This furnace replacement in their Rosman home ensures the new space has a dedicated, powerful, and efficient heat source. The customer is thrilled with how seamlessly the new system was integrated and is happy to have their addition ready for the cold months.
An owner of an older home decided it was time for a full heating system replacement before winter arrived, as their existing furnace was becoming unreliable. We guided the homeowner through selecting a new high-efficiency furnace that would provide dependable warmth for years to come. Our heating installation process included removing the old unit, making ductwork adjustments for better airflow, and carefully installing the new furnace. We then calibrated the system and tested all safety controls to ensure peak performance. The homeowner feels a great sense of relief knowing their furnace upgrade will keep them warm and worry-free.
A homeowner called us for an urgent AC repair in Rosman, NC, because their central air conditioner was not cooling on a warm September afternoon. Upon arrival, I performed a full diagnostic service and found the system was critically low on refrigerant. To provide a lasting solution, I conducted an electronic leak detection, a vital step for any proper emergency AC repair. I located and sealed a small leak at a service valve before evacuating the system and recharging it to the exact factory specification. The customer was grateful for the thorough repair and pleased to have their AC working correctly, mentioning they'd recommend our Transylvania County HVAC services to their neighbors.
Performed heating tune up service on heat pump systems checking all electrical components, refrigerant balance, unit start up, operation, shutdown, changing of customer provided filters. Everything looks and runs great!
Completed a heating system check-up for a small business, focusing on efficiency improvements and ensuring all components are in top condition.
Provided preventative maintenance for a multi-zone commercial heating system, testing all thermostats and balancing airflow across the building.
Performed cooling tune up on two heat pumps. Main system Blower is pulling 1.8 amps Temperature difference between return and supply is 20 Capacitor was replaced on outdoor unit and now within manufacturer specifications Compressor is pulling 7.6 amps Outdoor fan is pulling 1.3 amps Subcool is 8 superheat is 10 System is working great Second system Blower motor is pulling 1.2 amps Temperature difference between return and supply is 18 Capacitor is within manufacturer specifications Compressor is pulling 6 amps Outdoor fan is pulling 1 amp Subcool is 10 superheat is 13 System is working great. Cleaned coils and replaced filters.
Delta T of 30 on left Maytag and 35 on right Maytag. Checked blowers, coils, traps, and pumps. Brushed out drain traps. Added algae tablets to condensate pumps. Tested pumps. Heat kits working normally. Checked line temp and pressures. Tested both capacitors outside. Sealed test holes in ductwork. Systems are functioning normally.
Unit will not fire after propane lines were hooked back up. Incoming gas 13.5wc. Found igniter to be bad. Replaced and tested operation