Response from K&D Factory Service Inc.:
We are so grateful for your 5-star review. Thanks for sharing your rating with us and the community.
Commercial Kitchen Equipment Repair-Dishwasher Rinse Aid Adjustment: A dishwasher in a restaurant had trouble dispensing rinse aid properly. I fine-tuned the dispenser, improving dish cleanliness and operational efficiency.
Commercial Kitchen Equipment Repairs. I replaced faulty components in a commercial griddle, restoring even and efficient heating essential for food preparation.
Commercial Salamander Repair. An ignition system failure hampered a commercial salamander's functionality. I replaced the ignition system, ensuring quick and reliable performance vital for the kitchen’s operations.
Commercial Kitchen Equipment Repair Service: The client reported inconsistent cooking temperatures in their commercial oven. After a thorough inspection, I discovered a faulty temperature sensor. I replaced the sensor and recalibrated the oven, ensuring precise cooking temperatures for their kitchen operations.
Commercial Kitchen Equipment Repair: Replaced worn-out cutting boards in a food prep station to maintain hygienic surfaces.
Commercial Kitchen Appliance Repair: Calibrated the temperature probe in a tilt skillet for accurate cooking temperatures.
Commercial Kitchen Equipment Maintenance. Our team visited the client's establishment to perform maintenance on their kitchen equipment. We initiated the process by thoroughly inspecting each appliance for optimal functionality. Additionally, we cleaned the condenser coils within the freezer and refrigerator units. A meticulous check of hinges and gaskets on doors ensured secure closures, while a thorough cleaning eradicated accumulated grease. As a final touch, we replaced filters in all appliances to guarantee continued cleanliness and efficient operation for each unit.
Commercial Bread Proofer Installation. We installed a bread proofer for a bakery, optimizing dough fermentation. Positioning it precisely, we connected systems and calibrated controls. Thorough testing ensured consistent proofing conditions, enhancing bread quality.
Commercial Kitchen Equipment Repair near S Main St. Commercial Pizza Oven Repair. I arrived at the client's location to repair their commercial pizza oven. After inspecting the oven, I discovered a faulty heating element. I replaced the heating element and conducted tests to ensure the oven reached the desired temperature. The client was delighted to have their pizza oven fully operational again.
Commercial Kitchen Equipment Install near Canal St. Upon being notified that the refrigerated display case at a commercial business had irreparably malfunctioned, the owners sought our expertise for a solution. We diligently explored various options with the client, ensuring the selection of the most suitable and cost-effective appliance for their business. On the scheduled date, our team arrived promptly, carefully removing the old display case before proceeding to install the new and enhanced refrigerated display case in the establishment. The client expressed satisfaction with the improved performance of the upgraded appliance, further enhancing their business operations.
Water filtration is overdue to be cleaned and changed, and mold has started to form. Replaced moldy water filter
Checked hi limit on Gas Fryer, is good. Found a lot of carbon on limit. Cleaned off. Brought up to temp. Tested okay.
Conveyor Oven not heating, checked voltages, 237.7 High Voltage, But only 22.4 volts on Low Voltage, recommend to replace Transformer and relay, had 22.4 at gas valve but would not pull in, transformer is weak, contact said to replace both transformers in upper and lower unit. 9/05/19 Top oven, Replaced old Fenway ignition module with the new updated Fenway module. Cleaned ignitor, checked at set gas pressure to 4.0 in WC. Checked both cooling fans, okay. Unit still comes up with error Open and 909F error. Temp control module face is melted and probe is no good. Kyle said replace both ASAP. Bottom over, replaced obsolete Honeywell ignition module with the new Fenwal updated module, running now and seems okay. Cleaned ignitor, checked gas pressure and set at 4.0 in WC. Checked the 24 volt, seems okay, left the transformer with manager. Per Kyle. Will return with new Temperature module and probe to replace.
Cleveland Steamer - Removed and replaced boiler based steamers. installation is not complete. Unit will be completed tomorrow. 4/3/19 Made final connections. Let heat up to temperature. found no leaks. tested kettles connected. found ready to use.