Mark B.

Mark B. Job Checkin

Arrived at location on 1/16/23 - Once cleaned I examined unit and found gas line to burner ignitor was disconnected. Found loose fitting on valve side. Connected gas line and tightened fitting at valve. Turned on and checked for leaks, none found. Unit last pilot lights and burners fire. Noticed 2 burners not lit at all and 3 more with weak or fluttering flame. Marked burners and shut unit off. Pulled marked burners off and cleaned orifice and burner. Reinstalled burners and tested. All burners now light and have even flame. Okay.


Service C.

Service C. Job Checkin

Started taking Groen skillet unit apart, tilted bed, removed panel covers, started to disassemble burner manifold - noticed additional damage, took pictures. All burners are rusting thru and the frame up front that the burners rest on is rotting away. 11-19-1 Returned, replaced gas valve, all burner oriftcesand pilot tube orifice, need new burners and pilot runner tube Note: additional parts not part of this quote, will order on a new work order. Closing out this work order.


Service C.

Service C. Job Checkin

Examined unit. Turned on. Cycles. Blower running. Opened control panel. Found new interface board 12v. Light is lit. 24v 6v and power not. Will need new multivolt transformer. Will order and return. 3-6-17 Examined unit. Replaced multivoltage transformer and tested. Turned on, blew fuse on board. Traced back to ignition module. Replaced module. Installed new fuse and tested. Unit cycled and came up to temp.


Service C.

Service C. Job Checkin

Examined unit (BUN Coffee Machine). Water off, unplugged. Removed top, found hi limit melted. removed and replaced hi limit. Also replaced 1 terminal end. Assembled, plugged in and turned on water. Unit filled up then started to heat. 13.5 amps, all okay. Unit came to full temp and shut off all okay.


Service Check-In ..

Service Check-In .. Job Checkin

Duke Broiler Tech - Found no 24 volts to ignition bottom. Bottom heat 24volts out of transformer. Called Duke, said fuse in control. Removed controller and found fuse open. Replaced fuse, left spare with customer. Unit lit up. Ran product, tested ok.