Ashley B.

Ashley B. Job Checkin

Commercial Kitchen Appliance Repair Service: At a retail venue, where the frozen beverage machine's motor failed, disrupting slushy production, I replaced the motor. This ensures customers can enjoy their frozen beverages consistently.


Ashley B.

Ashley B. Job Checkin

Commercial Warewashing System Repair. Responding to concerns about inconsistent water heating affecting the efficiency of the commercial warewashing system, I performed a detailed inspection. Identifying a worn-out water heater element as the root cause, I executed a precision replacement. This essential repair guarantees that the warewashing system consistently operates with optimal water temperature, ensuring thorough and effective cleaning of dishes and utensils in a commercial setting.


Mark B.

Mark B. Job Checkin

Arrived on, 8-16-23 Ron F-Opened up each unit for inspector. He found each unit needs delimed and each unit needs new sight glass. Found far right unit may need element if can not be delimed. Returned on, 9-5-23 John S/Ron F-Opened each unit and replaced sight glasses on left, middle and right units.delimed each unit. Tested and found in working order at this time.


Mark B.

Mark B. Job Checkin

Preventative maintenance for commercial refrigeration equipment. Cleaned condensing coils, checked door gaskets, door hinges and condensate drain. All coils were blown out with nitrogen. Discussed recommended repairs and replacements with manager and changed out filters after talking.


Mark B.

Mark B. Job Checkin

Planned maintenance service for commercial refrigeration equipment. Replaced air filters, cleaned condenser coils, checked hinges, door gaskets, sells, and refrigerant levels. The thermostat is working properly and maintaining interior temperature.


Mark B.

Mark B. Job Checkin

Arrived at location on 7/21/22 - Checked over unit, pilot is lit, turned thermostat to 300F and let heat, when thermostat cycled off the oil temp was 22F over thermostat setting. Turned thermostat to highest setting of 375F and let heat again. When thermostat cycled off oil temp was 19F over. Let thermostat cycle a few times. Oil temperature remained between 15-19F over, thermostat will need to be replaced. Hi limit should also be replaced as it appears to be the original which could be contributing to their intermittent issue. Returned to location on 8/5/22 - Removed failed hi limit and thermostat, installed new hi limit and thermostat, lit pilot, turned on thermostat. Let heat, unit heated up and thermostat is cycling, confirmed unit working correctly at this time.


Service C.

Service C. Job Checkin

Checked over UNV Slicer unit. Found large gap between table and blade. Adjusted gap to 1/16". Sharpened blade per manufacturers instructions. Found sharpening stones worn and need replaced. 3/10/21 Removed worn sharpening and honing stones and replaced. Energized and sharpened knife per manufacturers instructions. Unit operating normally at this time. **No Travel Charges**


Service C.

Service C. Job Checkin

Checked over UNV Slicer unit. Found large gap between table and blade. Adjusted gap to 1/16". Sharpened blade per manufacturers instructions. Found sharpening stones worn and need replaced. 3/10/21 Removed worn sharpening and honing stones and replaced. Energized and sharpened knife per manufacturers instructions. Unit operating normally at this time. **No Travel Charges**


Service C.

Service C. Job Checkin

Checked over UNV Slicer unit. Found large gap between table and blade. Adjusted gap to 1/16". Sharpened blade per manufacturers instructions. Found sharpening stones worn and need replaced. 3/10/21 Removed worn sharpening and honing stones and replaced. Energized and sharpened knife per manufacturers instructions. Unit operating normally at this time. **No Travel Charges**


Service C.

Service C. Job Checkin

Found top steamer not responding to timer, found unit will only run in certain spot for timer. Disassembled timer and reassembled timer. Tested found to operate at this time. Found bottom cavity okay. Will need new timer and filter. 6/17/20 Removed defective timer, installed new timer, found water filter incorrect, will order correct filter and return to install, allowed unit to run, cycled timer, tested operations, confirmed unit working correctly at this time. 6/29/20 Removed old water filter, installed new water filter, purged filter, tested operations, confirmed unit working correctly at this time


Service C.

Service C. Job Checkin

Found Electric Steamer unit off. Turned unit on allowed to fill. Turned heat on found once unit started building pressure the unit would drain all the water to the point of tripping low level light. Checked drain valve found piece of debris was blocking valve from shutting all the way. Cleaned out valve reinstalled valve. Turned unit on let fill and let unit heat. Found unit to fill normally, heat, build pressure and steam each compartment and cycle appropriately. Turned unit off to verified drain valve operated. Turned unit on and let unit run normally for about 10 minutes. Unit is operating correctly at this time. Turned unit off and allowed to drain.


Service C.

Service C. Job Checkin

Checked Combi Oven unit, found probes coated. cleaned. ran unit found similar issue. checked errors found errors 1,3,2, found issue in full valve will need to order and return. customer also wants a case of descaler (part order). 1/11/19 Replaced valve and ran unit. found unit had error 4 and would not heat upon checking found error 4 is a fair probe fault. checked over found probe wire broke off probe behind cover. removed probe took apart and got it to work temporarily until probe comes in. will order and return. 1-17-19 Removed left side panel to access probe. Removed failed probe, installed new probe, energized and checked operation. Unit operating normally at this time. ** No Travel Charge per Service Manager**


Service C.

Service C. Job Checkin

Removed the faulty elements and power switch on Duke Table. Then installed new with sealant where needed. I checked operation and all the elements are working fine. There is an issue with power to the metal cabinet. The test power supply set up in the maintenance shop has no ground so when I checked from the cabinet to earth ground I have 120v with the DP power switch off. I spoke to their maintenance about checking their cords etc.. for possible issues. I ohmed out the cord on the unit but didn't find anything between connections. But there still could be any issue but only when enough voltage is applied like insulation is wearing thin on wires. The bid work is complete at this time.


Service C.

Service C. Job Checkin

Found Steamer unit off. Replaced old boiler with new boiler. Turned unit on, allowed to heat and create pressure. Found unit okay. Unit operates correctly at this time.


Service C.

Service C. Job Checkin

Removed MFO Streamer level probes, filled with descaler, filled boiler with water and let descaler work. Cleaned scale deposits off level probe. Drained boiler refilled and allowed to drain again. Inspected door area ensued bolts and screws were tight adjusted spring. Door now seats when raised.