Service C.

Service C.


Job Checkin

Checked top toaster and it powers up and heats but no cooling fans and no power to them from the motor board. Conveyer Motor is working. Pulled the toaster and removed the bottom and found the wires melted and shorted causing damage to the board. Need a conveyor/fan board and wire kit. I'd part from Benard in service at AJ Antunes . Will order and return. not in service. Order QWP (expedited freight) per James M. 1/4/19 Pulled top muffin toaster to an area to work on it. Disassemble and removed the shorted wires and installed the new wire kit per instructions . removed the old damaged motor/fan control board and installed new board. Zip tie wires in place and moved toaster back in place. 214 vac to toaster. Powered on and unit now heats and fans are now working. Conveyor working. Allow to reach set temps and test . Unit is at temp and is okay. Muffins are toasted properly . No errors. In service .