During today’s visit, performed inspection and maintenance on one attic furnace unit and one crawlspace furnace unit. inspected flue pipes and ductwork for leaks. Inspected overall cleanliness of the blower and burner compartments. Inspected blower capacitors. inspected flame sensors and igniters. Inspected pressure switches and burners. performed ignition sequence on both systems and inspected flames. Inspected temperature heat rise on both systems. The upstairs system has a blower capacitor that is measuring below specifications. It is recommended to replace the blower capacitor at this time for that system. Otherwise, both systems are functioning normally at this time.