140 Icon Ct.
Sparks, NV 89441
(775) 786-4357

Job Locations
for portola, ca


Map of Portola CA
Adam B.

Adam B.


Job Checkin

BOILER REPAIRS: I installed I installed the new components into the boiler system to get it functioning without having a fault code. Once objectives were completed I pumped the glycol back into the system that had to be removed to drop pressure off the system. I turned the unit on and had cycled it between heating and hot water to verify operation. Everything is back up and running as well as no water leaks. ITEMS REPLACED: - starting flue shroud - seals for the flue shroud - high temperature flue limit switch - return temperature sensor - water pressure sensor - daughter circuit board, controls the sensors - repaired a minor leak - installed a debris guard over daughter board