Air Conditioner Maintenance North • Cleaned AC • Vacuumed debris from condenser • Wash condenser coil • Torque Schrader cores • Tightened king valves • Check for refrigerant leaks at service valves • Replaced filter 18x20 • Condenser fan motor amps 1.2 and compressor amps 14.3 • Check contactor • Compressor and OD fan cap MFD 70/10 • Blower amps 9.8 • Inspect coil Air Conditioner Maintenance South • Cleaned AC • Vacuumed debris from condenser • Wash condenser coil • Torque Schrader cores • Tightened king valves • Check for refrigerant leaks at service valves • Replaced filter 18x20 • Condenser fan motor amps 1.3 and compressor amps 13.6 • Check contactor • Compressor and OD Fan cap MFD 70/10 • Blower amps 9.7 • Inspect coil Air Conditioner Maintenance Patio • Cleaned AC • Vacuumed debris from condenser • Wash condenser coil • Torque Schrader cores • Tightened king valves • Check for refrigerant leaks at s