140 Icon Ct.
Sparks, NV 89441
(775) 786-4357

Job Locations
for dayton, nv


Map of Dayton NV
Brandon W.

Brandon W.


Job Checkin

90% Furnace Maintenance 2nd visit • Cleaned furnace • Cleaned burners • Cleaned flame sensor and checked hot surface igniter • Cleaned filter grill • Replaced filter 20x24x1 • Verified no gas or CO leaks • Blower amps 4.6 • Inducer motor amps .8 • Blower capacity MFD R:5 A:4.5 • Cleared pressure switch hose • Cleared condensate line • Static pressure R/A .28" w.c. • Static pressure S/A .29"w.c. • Combustion Oxygen % 8.2 • Combustion CO PPM 23 Air Conditioner Maintenance 2nd visit • Cleaned AC • Vacuumed debris from condenser • Wash condenser coil • Torque Schrader cores • Tightened king valves • Check for refrigerant leaks at service valves • Clean filter grill • Replaced filter • Condenser fan motor amps .9 and compressor 10.1 • Check contactor • Compressor and OD fan motor cap MFD R:45/5 A:45.1/5.2 • Inspect coil • Static pressure R/A .31" w.c. • Static pressure S/A .33" w.c. Replaced failing 5 mfd blower motor capac