Air Conditioner Maintenance 1st visit • Cleaned AC • Vacuumed debris from condenser • Wash condenser coil • Torque Schrader cores • Tightened king valves • Check for refrigerant leaks at service valves • Clean filter grill • Replaced filter 20x30x1 • Condenser fan motor amps 1.1 and compressor amps 12.2 • Check contactor and found pitted with burnt contacts • Blower cap MFD 10 and compressor and OD fan motor MFD 70/10 • Blower amps 5.6 • Inspect coil • Static pressure R/A .28 • Static pressure S/A .3 Replaced failing contactor and recommended 5-2-1 compressor saver to extend life of compressor and save money on energy cost every!