Customer report no cooling Son had taken off cool door and condenser panel in an attempt to see if he could fix it himself but he could not figure it out Turned cool mode on thermostat, blower came on and condenser fan came on but no cooling. I hooked up my gauges and noticed refrigerant was not cycling, did and amp draw checked and noticed compressor was not pulling amps Checked system and found mfd on compressor side to be at 0 Diagnosis is failed capacitor. Replaced capacitor and unit came on including the compressor. Even with unit on I was still not getting any cooling, checked gauges and found it to be low on refrigerant. Informed customer she has an r22 system and that that refrigerant has been phased out as of January of this year Option 1: replace air conditioner Option 2: Put in leak seal and fill up with r22. This is not recommended as r22 is phased out so if leak seal does not fix unit and it leaks again there is ZERO warranty on fix.