Job Checkin

Air Conditioner Maintenance: - Cleaned AC - Vacuumed debris from condenser - Wash condenser coil - Torque Schrader cores - Tightened king valves - Check for refrigerant leaks at service valves - Clean filter grill - Replaced filter - Condenser fan motor 1.1amps - Compressor 8.1Amps - Check contactor - Run Cap 45/5MFD - Static pressure R/A: .2WC - Static pressure S/A: .3 WC Contactor is burnt, pitted and charred. Contactor is responsible for allowing power to pass into unit. When contractor pads are burnt, pitted and in poor condition it will eventually stop allowing electrical current to flow and air conditioner will not work Low temperature split at only 10 degrees. During previous maintenance Brandon price had a similar issue and did a full leak check and nitrogen high pressure test of the system and no leaks were found in the lineset or coil which means that the leak is in condenser and is not repairable. Brandon re charged the system for customers last year and made sure to