140 Icon Ct.
Sparks, NV 89441
(775) 786-4357

Job Locations
for reno, nv


Map of Reno NV
Eric R.

Eric R.


Job Checkin

Air Conditioner Maintenance • Cleaned AC • Vacuumed debris from condenser • Wash condenser coil • Torque Schrader cores • Tightened king valves • Check for refrigerant leaks at service valves • customer Replaced filter • Condenser fan motor amps1.1 Compressor amps 23 • Check contactor • Dual cap MFD 50/5 • Blower amps 9.8 and noisy upon start up • Inspect coil • Static pressure R/A .5 • Static pressure S/a .26 20 degree indoor split Blower struggles a little upon start up Contactor is burnt, pitted and charred. Contactor is responsible for allowing power to pass into unit. When contractor pads are burnt, pitted and in poor condition it will eventually stop allowing electrical current to flow and air conditioner will not work. Customer is aware that the system needs replacement soon and is waiting to replace