140 Icon Ct.
Sparks, NV 89441
(775) 786-4357

Job Locations
for sparks, nv


Map of Sparks NV
Eric R.

Eric R.


Job Checkin

Air Conditioner Maintenance: - Cleaned AC - Vacuumed debris from condenser - Wash condenser coil - Torque Schrader cores - Tightened king valves - Check for refrigerant leaks at service valves - Clean filter grill - Replaced filter - Condenser fan motor 1.2amps - Compressor 15.5Amps - Check contactor - Run Cap 48/5MFD - Inspect coil - Static pressure R/A: .41WC - Static pressure S/A: .22WC Average lifespan for an AC is 15-20 years. This current AC is 18 years old which puts it in prime position for major component failure to occur. Suggest preparing to replace AC Current air conditioner uses r22 refrigerant. R22 has been phased out since 2010 and starting January 1, 2020 it will not longer be made nor able to import into the United States AC fan motor is running Near maximum amperage. Suggest annual Maintenance to continue to keep eye on worsening condition. As amperage continues to rise the motor will be at higher risk for failure. Air conditioner does not have proper drai