140 Icon Ct.
Sparks, NV 89441
(775) 786-4357

Job Locations
for verdi, nv


Map of Verdi NV
Brandon W.

Brandon W.


Job Checkin

Mobile Home Furnace Maintenance • Cleaned furnace • Cleaned burner compartment • Cleaned flame sensor • Cleaned filter door • Replace filter 2(16x20x1) • Verified no gas or CO leaks • Blower amps 6.7 • Inducer motor amps (na) • Blower capacitor MFD (na) • Cleared pressure switch hose (na) Found very old furnace on its last leg with bearings going out on blower and vibrating entire wall. Thermocouple is failing. Due to age and inefficiency of unit and considering it past it’s life expectancy it’s not worth putting any money into. Any questions please call Brandon 602-736-3077 (refer to estimate)