2017 upstairs equipment is in great shape and operating properly. Increased airflow to medium speed. System is in good working order. 2007 downstairs system was found to be in poor condition. Dual Run Capacitor is depleted beyond tolerance and needs replacement. Indoor and outdoor coils are in need of cleaning. The interior of the cabinet needs thorough sanitization, as well as the ductwork. Drain line was 100% restricted leaving standing water inside of the air handler. Significant population of bacterial growth exist inside of the air handler cabinet. System is recommended to be replaced at soonest availability. While steps may be taken to mitigate the current issues, repair is not advised. Dehumidifier in crawlspace is currently operational, however the crawlspace is in need of being properly encapsulated in order for the dehumidifier to be of proper benefit to the home. Dehumidifier replacement is recommended upon proper encapsulation of the crawlspace. This investment is great