577 Sterling Drive
Richardson, TX 75081
972-591-0199

Job Locations
for corinth, tx


Map of Corinth TX
Russ T.

Russ T.


Job Checkin

Call back for heater not working. On arrival the system was turned on in heat mode and the condenser was found to not be turning on. The condenser was opened up and was found to have no power going to it. The manual disconnect switch was found to have been turned to the off position. The switch was turned on and the system started up. A basic heat checkup was then performed and the emergency heat was also not found to be turning on. This was caused by the wire from the heat strip having slipped out of the wire nut that connected it to the thermostat and condenser. This was also fixed and the heat strip turned on properly the unit was observed running and brought the temperature in the house up 8°. The homeowner was out of town during this visit and the hot water heater in the garage was noticed to be leaking water. The water heater was shut off and it is recommended that the homeowner call a plumber to address this issue.