Ray & his helper were great to work with! They were friendly and personable. They were efficient and cleaned up after themselves, part of which was messy from clearing a condensate line.
Emmanuel is always great! Listens, concerned, patient an attentive.
Excellent communication and first rate service by Emanuel.
Emmanuel is fantastic! He is personable, listens to what you say and explains any concerns you might have very well. He takes a genuine interest in his customers.
Joel was very courteous but went straight to work. He helped me get started on reconnecting my wifi and thermostat ap. While I completed that he inspected both of my units and tested my carbon monoxide monitor.
Response from AC Pros:
Brad, Thank You for the 5 star! -Sincerely, Russ and Laura Teager AC Pros
Put 5 ton condenser for upstairs and the 4 ton to downstairs. Also corrected U/S drainage issue
Checked system, homeowner stated that airflow for upstairs rooms are a little weak. Made adjustment to control board to increase cooling cfm. Outdoor unit had a 13 degree subcool. No refrigerant leak. He also had to clear the drainline out over the weekend because the float switch was being triggered.
System maintenance on new install, amps are good, dry drain pan, filter new, pressures are good, temp split is good, compressor and fan amps are good, capacitor is within range, unit cooling at this time
Came out for no cool found clogged drainline. Cleared drainline system is now operational.
Disconnect was never turned on after the maintenance. Turned it back on and system is cooling now.
Performed one system maintenance. All checked out fine, aside from thermostat was not picking up the y1 initially. Reconfigured the ecobbe so it could pick up the y1. System cooling perfectly.
Came out for no cool found bad capacitor at the blower motor. I didn't have a 10mfd on my van. Coil was frozen. Return tomorrow to replace capacitor.
Upon inspection found no issues at this time but advised homeowners that the main system will struggle this summer do to low refrigerant charge (R22)...homeowner elected to wait til later in the season to charge.
Competed with no cool on a 2022 american standard with 2014 Lennox furnace and evaporator coil gas horizontal in attic. Found restricted evaporator coil with txv. Gave the option to do minimum repairs, or complete unit upgrade with additional 13 inch return.
Upon inspection found no issues at this time, tested pressures, delta,and SH,SC to balance.
Performed maintenance. Both system are cooling perfectly.
Complete Two system heating tune Recommended replacing blower motor for downstairs unit Recommended duct work repairs See estimate
Two systems cooling tune up. Tested pressures, subcooling, compressor amps, and fan amps. Inspected contactor and capacitor. Recommended contactor and capacitor
One system heating tune up. Inspected blower, furnace, ductwork, and safety devices. Tested for carbon monoxide and gas leaks. System is working properly at this time. Changed filter 20x25x4 Ms. Barnard said she found black particles throughout home. Found that supply ductwork is old brittle and starting to breakdown, duct work is also coated with growth and bacteria. Recommended ductwork replacement
Preformed the fall maintenance on the 2 systems. The heatphm9 system is operating properly at this time. The main system has rust that will lead to a Crack on the heat exchanger, the evlaporator coil is dirty. Consideration for system replacement should be done soon.