Performed ac maintenance. Air filters from 11/23 are still clean. Delta t are 22 and 23 degrees. Blowers drawing proper amps. Furnaces are 2 yrs old and evap coils are 6 yrs old in good shape. Drains are clear. Outdoor units operating great. Those are 2 yrs old as well. Rinsed condenser coils.