Rated 5.0 out of 5 stars based on 4 customer reviews

Excellent work

Tech was very honest and great to work with !! Would highly recommend

  • Overall Experience
  • Quality
  • Price
  • Convenience

Annual Routine Maintence

  • Overall Experience
  • Quality
  • Price
  • Convenience

Jeff did a great job repairing an AC fan at my property today

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Very good company to do business with. Very fair and they do excellent work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for little elm, tx

Collin F.

Collin F. Job Checkin

Verified the leak in the evaporator coil. Left the customer with options for replacement. See pictures.


zwschmitt@gmail.com

zwschmitt@gmail.com Job Checkin

Preformed maintenance with all proper checks and cleanings. adjusted gas pressures and found filter does not fit. system is clean and working properly at this time.


zwschmitt@gmail.com

zwschmitt@gmail.com Job Checkin

checked system out and it is working properly at this time.


zwschmitt@gmail.com

zwschmitt@gmail.com Job Checkin

Zac preformed maintenance. found capacitor to be out of range but still operating. also found that i could not take off locking caps as they broke my tool for taking them off.


Nicholas S.

Nicholas S. Job Checkin

Today is covered under maintenance agreement trip 1 of 2 for summer check. The capacitor swelled up causing the condenser to not properly engage and start the cooling process. After capacitor replacement the system began to run normally


Russ T.

Russ T. Job Checkin

Performed two system cooling maintenance, replaced customer supplied air filters. Indoor equipment is still in good shape. Made homeowner aware of evaporator coil for downstairs being 3.5ton and condenser is 4ton. She will call builder to get an explanation on how to move forward. Would recommend float safety switch on the primary drain line since there is no float safety devices at all on either system. Proceeded to outdoor unit capacitors, motors, and compressors all reading within manufacture, specs, rinsed off condenser coils with water only systems are cooling at this time. Will make recommendations for SS1 float safety devices. Equipment not registered under Rusca name, according to Carrier.


Joel S.

Joel S. Job Checkin

After extensive test I have determined that the refrigerant is contaminated. Are the pressures in the test mode end up extremely low on the low side but OK on the head pressure. Ray will be back tomorrow to recover all refrigerant and install a new liquid line dryer and fill unit back up


John h A.

John h A. Job Checkin

Disconnect on outdoor unit was missing replaced with new indoor blower motor sucked up the filter and was attached to the coil up flow unit , cause the unit to trip off high head pressure, cold filter was blocking airflow threw the house, also back side of coil is real dirty, homeowner had filters .


Jeff S.

Jeff S. Job Checkin

Completed diagnosis, primary drain line was clogged up, tripping float safety switch. Installed drain isolater and cleared drain line. Now everything is operating properly.


Jeff S.

Jeff S. Job Checkin

Performed maintenance on heat. All safety limits, inducer draft motor, and blower motor are fine. No carbon monoxide or gas leaks detected. Attic insulation looks good. Temperature rise and gas pressure is on point. Everything is operating properly. Filter needs to be Changed out in about 2 months.


Joel S.

Joel S. Job Checkin

Heat performance tuneup times two systems. Advised Sharece that both filters need to be changed. Inspect blowers, evaporators and ductwork. Test all safety features high limits and roll outs. Check heat exchangers for cracks found none. Check temperature rise on both systems. Both temperature rises were high due to a dirty filter. Check thermostats for proper operations. No carbon monoxide or gas leaks detected in home. Systems operating at manufacture specs at this time.


Jeff S.

Jeff S. Job Checkin

Washed condenser coils, drains are clear Replaced media filter. Run capacitors, refrigerant levels. Everything is working properly.


Jeff S.

Jeff S. Job Checkin

Washed condenser coils, drains are clear, blower/compressor and fan motor amps are in range. Refrigerant levels and run capacitors were good.


Jeff S.

Jeff S. Job Checkin

Completed diagnosis, downstairs 18 dampers is sticking close, causing system to freeze when upstairs is satisfied. No other problems found at this time. Also refrigerant levels are good, sub cooling around 11. Note: customer has $75.00 coupon.


Jeff S.

Jeff S. Job Checkin

Upstairs system was low on 410a, charged system with 4 pounds of 410a. Customer knows that system needs to be replaced. Had conversations with Jim the comfort advisor. No warranty or guarantee on refrigerant.