2040 E. Fairview Ave.
Meridian, ID 83642
(208) 855-2444

Job Locations
for kuna, id


Map of Kuna ID
Derrick N.

Derrick N.


Job Checkin

Furnace inspection complete found to be operating ok at this time. Issues found with system 1. Furnace venting rusting out needs replaced with proper up to code “B” Venting. 2. Replacement of water heater expansion tank needed. 3. Replacement of igniter for furnace needed soon “Still working at this time” 4. Blower cleaning 5. Duct cleaning 6. Minor duct repair per inspector “re-strap” 7. Evaporator cleaning Inspected ducting in crawlspace going to master bath it is up to code and operating perfectly fine