2040 E. Fairview Ave.
Meridian, ID 83642
(208) 855-2444

Our Top Cities


Local Reviews

Rated 4.9 out of 5 stars based on 783 customer reviews

Great tech

Very informative about what I need to do.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Nice folks

Very polite and thorough.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Tech bisit

What super nice guy. The kind of person you feel so comfortable with that if you had to leave him alone in your hom you could do it. He also was no pressure, polite an clean cut looking. He put a sticker on my furnace an I definitely plan on using your company if I need any repairs. Thanks again, James Barrett an Access Heating Barbara Shearet Boise

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service review

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Brandon made sure I understood everything he was doing and showed me what needed fixed and why.

  • Overall Experience
  • Quality
  • Price
  • Convenience

furance maintenance

did not do a full cleaning job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

John was very professional and prompt...answered all my questions very well.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Quick, friendly, fast and a job done well!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

thank you he was working fast and got the job done thank you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

James B.

James B. Job Checkin

Reviewed settings in thermostat. Reviewing with Aaron. Pictures stored in file.


Jeff D.

Jeff D. Job Checkin

Check system and found furnace not igniting. Checked igniter probe all is operating properly but was not set in flame properly to ignite. Readjust igniter and cycled on several times all is working good at this time.


Derrick N.

Derrick N. Job Checkin

Did the pictures and measurements for the free furnace contest.


Jeff D.

Jeff D. Job Checkin

Checked water heater operation found pilot light would not stay lit. Checked valve and controls found gas valve not working properly. Replaced gas valve, system cycled on good and is working properly. Also performed maintenance and flush on water heater. Found water connection leaking, tightened all water flex connections and is good and leak free at this time. Also found expansion tank defective, diaphragm in tank has been ruptured and needs to be replaced. Replaced expansion tank and pressurized it to 70 psi per house pressure and is operating good.


Derrick N.

Derrick N. Job Checkin

Did pictures and measurements of the furnace for the contest


Derrick N.

Derrick N. Job Checkin

Completed entry into the free furnace contest with the pictures and measurements. System age is 2002-2003


Derrick N.

Derrick N. Job Checkin

Free furnace entry invoice, the furnace is a 1992 up flow in the basement, this is a Lennox Pulse furnace this serial number is possibly under the old expired Recall they had in the late to mid 90’s.


Jeff D.

Jeff D. Job Checkin

Checked system operation found combustion inducer assembly motor has excess of end play and causing the motor to rattle. Also performed overview of heating system and found secondary heat exchanger has a major hole and is leaking condensation Onto the primary heat exchanger and resting the chamber out very badly. Shut system down due to unsafe conditions and improper functioning of combustion. Heating system can be repaired but with that age and cost of repair, replacement may be a better option.


Derrick N.

Derrick N. Job Checkin

Input all system information in for the free furnace contest.


Brandon A.

Brandon A. Job Checkin

Completed ac maintenance. System is working properly at this time.


Derrick N.

Derrick N. Job Checkin

Input of all pictures and measurements for the free furnace contest


Derrick N.

Derrick N. Job Checkin

Input furnace contest information


Brandon A.

Brandon A. Job Checkin

Completed system inspection. Found system working properly at this time. Noticed system has some signs of wear due to age, dirty blower wheel, and fraying thermostat wire at the condensing unit. But system is operating properly at this time.