3270 Kino Ave
Kingman, AZ 86409
888-221-4702

Job Locations
for kingman, az


Map of Kingman AZ
Michael A.

Michael A.


Job Checkin

Install customer Provided Ice cuber, Condenser and line set. Ambient is to remove existing system, run new lineset, install rooftop condenser, ice cuber. Arrived on site and checked in with manager. Was shown equipment behind store to be installed. Went to roof and recovered charge. Cut away lineset from condenser. Crane removed equipment from roof and set new condenser. Welded in lineset and reattached existing disconnect switch. Went into store to ice machine next to subway in closet for fountains. Cut away lineset and removed electrical. Used lift to remove ice machine and took outside next to dumpster as per instructed. Brought new ice machine in with lift and set into place. Reattached drain line, line electrical, remote condenser whip, and water line. New ice machine came with new bin switch with sensor. Installed per factory instructions. Ran new lineset from ice machine to condenser. Welded lineset behind ice machine to keep close to wall. Pressure tested all welds and pulled