Unit has a refrigerant leak (r22), burnt/failing contactor, hard start kit (on the compressor) that needs to be replaced, failing dual capacitor that needs to be replaced. Will need to add missing refrigerant with leak seal, AC renew and dye. Install new contactor. Install new dual capacitor. Install new hard start kit and test unit operation. More quotes may follow. Robert I (checked out with) Checked in with Leo Thawed unit. Removed dirty air filter and advised resident to replaced air filter in the next few days (1) 20x20x1. Replaced dual capacitor on outdoor unit. Replaced contractor and hard start kit on outdoor unit. Added r22 refrigerant. Added uv dye, leak seal and ac renew. System was cooling at the end of service call. Advised resident and Leo that system has a leak and repairs made today are only temporary. Leo asked for a new unit estimate emailed to him and they will consider replacing it next month. System was cooling at the end of service call. System was putting out