Put sticker on unit, unit is ready for inspection
RE USE EXISTING HEAT STRIP PER DAVID T 474
Checked over the system to find everything to be working as designed. 53 percent humidity. 77 degree return air with. 55 degree supply air temperature. 56 degree wetbulb. 125/316 psi 12 degree Superheat. 8 degree Subcooling. 55 degree suction line temperature. 92 degree liquid line temperature. Sealed the air handler around the return and resealed around the supply. The system cooled down 3 degrees while checking it's operation.
Installed the metal riser. 4/9 Assisted Matt C with 16" metal RA riser
Checked over the system to find everything to be working as designed. 53 percent humidity. 77 degree return air with. 55 degree supply air temperature. 56 degree wetbulb. 125/316 psi 12 degree Superheat. 8 degree Subcooling. 55 degree suction line temperature. 92 degree liquid line temperature. Sealed the air handler around the return and resealed around the supply. The system cooled down 3 degrees while checking it's operation.
Found that the filter door was making a noise. Sealed the top and bottom of the filter door and also tightened all the screws on the outside condenser.
This is An Estimate to Install A New Carrier 16 seer Two Stage Heat Pump.
Went over the install, helped Wes with a couple things while on the job site. The one concern I have is that the condenser is not at least 12 inches away from the house.
Found that the customer already set up the wifi. Went over the customers questions about the thermostat. Set up the schedule and backlight settings.