Customer called due to system not operating in cooling when I arrived everything was operating except compressor. Found system to have a bad 45/5 dual capacitor replaced capacitor compressor would still not come on. Felt compressor did not feel warm used water hose to cool compressor anyway just in case. Could not get compressor to start compressor is pulling LRA and will not turn to start. Used hard start kit to get compressor to turn over would not operate. Found system to have a bad compressor. Left new capacitor on unit for compressor replacement. Ordering new compressor office will contact customer with scheduling. System is not operating at this time.