21450 NW 6th St
Dunnellon, FL 34430
(352) 362-8525

Our Top Cities


Local Reviews
for dunnellon, fl

Rated 5.0 out of 5 stars based on 11 customer reviews

Excellent Service

AC went out on Friday evening. Out of 7 companies called that said they offered 24/7 emergency service Chris of Blue Sky is the only one that returned my call. He tried to help me out remotely but parts were necessary. Came over Monday morning to diagnosed the problem and ordered the part and returned to install as soon as they came in. Very polite, professional and efficient. I would highly recommend them!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chris's awesome performance

We are totally satisfied with Chris's communication, promptness and his work ethic.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Totally satisfied!

On the ball, excellent communication with me on when they would arrive and time it would take to install 2 ton unit with air handler. Left no trace. Cleaned work area up. Explain how a thermostat worked and how to take care of the unit. I am completely satisfied and pleased that I chose Bluesky Cooling Comfort.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Satisfied!

Great Company!, Chris was on time, knowledgeable and honest.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Services

The guys were very efficient and friendly. Did their job well.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service! Very dependable!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding professionalism.

Awesome experience from start to finish. Chris and his helper were very professional and made the whole process painless. They took time to answer questions during the install. Would highly recommend this company!

  • Overall Experience
  • Quality
  • Price
  • Convenience

quality service at affordable prices

Blue Sky had kept my antique a/c unit going for the last four years with fast professional, courteous service, but my 16 year old system finally kicked the bucket and could no longer be resurrected. Blue Sky Quoted me a quality complete replacement unit at a very fair price. They scheduled me in for the job on a Friday for the work to be done on Monday. Started in the morning Removed the old unit, installed the new unit, cleaned up and took way the old unit. We were up and running By 5:00. Amazing job by Chris and his team.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Chris was very responsive and explained exactly what needed to be done to replace the existing AC unit. He was able to install the AC unit within a few days during one of the hottest days in Florida. He also was able to drop off a room AC fan to help cool the house while waiting for the AC unit to be installed. It was a pleasure to do business with Chris!

  • Overall Experience
  • Quality
  • Price
  • Convenience

you people are the best the best price

I wish every body would have your company for service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service - sevice tech was great

Annual maintenance, fixed system not working.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for dunnellon, fl

Christopher S.

Christopher S. Job Checkin

Customer reported no cool. Scheduled SAME day appointment. Upon arrival found system in alarm mode. Compressor. Found defective dual capacitor. Removed defective part. Installed new capacitor. Started system and checked all amperages. Each within manufacturer’s specifications. system running again


Christopher S.

Christopher S. Job Checkin


Gabriel S.

Gabriel S. Job Checkin

Bluesky Cooling Installed high-efficiency AC units in my home. I have a 16 SEER 4 Ton and a 16 SEER 2.5 Ton Heat Pump. These units are designed to provide efficient cooling and heating, helping me reduce my energy bills and improve the comfort of my home.


Christopher S.

Christopher S. Job Checkin

Customer reported no cool. Upon arrival found defective transformer that was replaced. Once new transformer was installed the control fuse blew out. After further troubleshooting found defective reversing valve solenoid had failed. We ordered the new part. Returned the next day and installed new part. Tested operation. The system is now operating properly.


Christopher S.

Christopher S. Job Checkin

Customer approved proposal to replace three systems. With Daikin systems. Upon installation removed original systems. Removed defective air handler deck and defective return plenum on 4 ton system. Fabricated new return air plenum and installed. Added support before installing new air handler deck. Removed UV light to reuse on new system. Installed new air handlers, heaters, float switches, thermostats and condensers. Transitioned new air handler to existing supply duct. Nitrogen purged lines during soldering process. Pressure tested lines. Pressures held. Evacuated system. Wired up each system and thermostat. Started and checked operation. Systems running as per manufacturers specifications.


Christopher S.

Christopher S. Job Checkin

Customer reported two ton unit compressor not starting. Scheduled next day appointment. Upon arrival checked compressor for ground and for short circuit. None found. Checked capacitor. The capacitor was within range. Started compressor. Compressor drew lock rotor amperage. Indicating Defective compressor. Placed order under warranty with TRANE 2/10/2023 Picked up new compressor at local TRANE distributor. Returned to property. Recovered refrigerant. Removed defective compressor. Installed new compressor. Pressure tested OK. Evacuated system. Charged system with recovered refrigerant. Reconnected electrical to compressor. Restored power to system. Started system and checked operation. Adjusted refrigerant levels. System operating properly.


Christopher S.

Christopher S. Job Checkin

Performed scheduled maintenance. As part of maintenance, blew out drain line and treated with algicide tablets. Checked operation in cool and fan modes. Checked temperatures, amperages and electrical. All within manufacture’s specifications. Replaced electrical connection in heat pump condenser, found filter clean.


Christopher S.

Christopher S. Job Checkin

System only running in heat mode. Found defective thermostat. Ordered new one thermostat under warranty. Returned and replaced. System running in all modes.


Gabriel S.

Gabriel S. Job Checkin

Problem - Found no low voltage. Determined system had a defective transformer. Replaced Transform and added a low voltage control fuse. When tested again newly installed fuse blew. Found heater contactor shorted. Removed and installed new contactor. Restored power and checked operation. System operating properly at this time.


Christopher S.

Christopher S. Job Checkin

Installed new 4.0 Ton Heat Pump Package unit (14 S.E.E.R) Air conditioning system. As part of the install recovered refrigerant and removed original equipment. Installed new return air plenum stand, media filter, air handler, heater, heat pump condenser, float switch and thermostat and tie downs. Wired in electrical. Transitioned new air handler into existing supply plenum. Brazed refrigerant lines and pressure tested system. Leak checked. Evacuated system. opened isolation valves and started system. Checked operation in heat, cool and fan modes. Started system and operating to manufactures specifications. Registered for equipment warranty and left permit with homeowner for purposes of inspection.


Christopher S.

Christopher S. Job Checkin

New Air Conditioning System installation. As part of installation added new air handler deck. New air handler, filter rack, heater, float switch, thermostat, hurricane pad and heat pump condenser. After Installation pressure tested new connections, Evacuated system. Opened isolation valves and started system. Checked operation. System operating to manufacturer’s specifications. Requested and delivered extended mfr. warranty.


Christopher S.

Christopher S. Job Checkin

Customer reported no cool. Performed Coil cleaning. System performing ok


Christopher S.

Christopher S. Job Checkin

Installed new Heat Pump System (AC). Included applying for permit, removing and disposing of old equipment testing and insuring new system working properly


Christopher S.

Christopher S. Job Checkin

Installed new Heat Pump System (AC). Included applying for permit, removing and disposing of old equipment testing and insuring new system working properly


Christopher S.

Christopher S. Job Checkin

Installed new American Standard Air Conditioning System. Removed, rebuilt and reinsulated Air handler plenum due to poor condition. Installed new air handler, heater and line chase. Leveled area around original pad for new hurricane pad. Returned following day and installed new copper line set and, pad and heat pump condenser. Secured heat pump condenser to new pad. Pressure tested new connection. Pressures held. Installed new programmable thermostat. Started system and checked operation. Operating to manufacturer’s specifications. Registered equipment.