Performed cooling HVAC maintenance today. Cleaned Trane XR14 condenser coils with Nu-Calgon Evap Foam. Replaced air filter with MERV 11 pleated filter. Checked refrigerant levels using Fieldpiece SMAN460 manifold gauge set. Cleaned condensate drain line with CO2 cartridge blaster. Lubricated fan motor bearings with 3-IN-ONE motor oil. Tested capacitor with Fluke 902 FC HVAC meter. Inspected ductwork for leaks. Calibrated Honeywell T6 Pro thermostat. Maintenance completed in 2.5 hours.