30045 FM 2978 Rd.
Magnolia, TX 77354
(281) 651-5484

Job Locations
for cypress, tx


Map of Cypress TX
Juan  M.

Juan M.


Job Checkin

AC Diagnostic System: Refrigerant Type R22 Metering Device-Fixed Orifice SP/HP 67/362 SLT/LLT 54/94 VSAT/LSAT 39/155 SH/SC 15/65 Outdoor Entering Air Temperature 92 Filter Size(s) 2 16x25x1 Returned tstat to original settings: Y Unit operational; prior to leaving: Y After recovering 3 pounds SP/HP 67/275 SLT/LLT 54/94 VSAT/LSAT 39/121 SH/SC 18/27 Outdoor Entering Air Temperature 92 Notes: Performed inspection and very high SC and low SH condenser was clean, so removed 3 pounds of R22 to get levels closer to manufactured specs. Did let customer know that it would be best to replace system since it’s 15 years old, but customer did not want to replace unit at this time Recommendations: CA