System: Downstairs Approx Age of System: 3 Combustible Gas Leak Detection Pipe and fittings leak-free: yes Valves and orifices leak-free: yes Carbon Monoxide Testing Walk-around CO: pass/ppm-0 Airside CO: pass/return ppm-0 supply ppm-0 Flue gas CO: pass/ppm-35 Ignition and Combustion Delayed ignition: no Flame disturbance: no Flame discoloration: no Motor Amperages and Capacitors Blower motor FLA: 5.6 Induced draft/combustion blower motor FLA: .6 Capacitor(s): pass Temperature Rise Rated: 25-55 Actual: 43 Static Pressures Blower speed/cfm: RP- .36 /FS- .22 /SP- .1 TESP: .58 Safety Controls Primary limit test: pass Filter sizes: 20x25x1 Changed filters: no. It’s clean. Scheduled next tune up date: Notes: ________________________________________ System: Upstairs Approx Age of System: 3 Combustible Gas Leak Detection Pipe and fittings leak-free: yes Valves and orifices leak-free: yes Carbon Monoxide Testing Walk-around CO: pass/ppm-0 Airside CO: pass/return ppm-0