System- Approx Age of System: 5yrs Refrigerant Type- R410a Metering Device- TXV SP/HP: 128/355 SLT/LLT: 58/104 VSAT/LSAT- 44/108 Superheat/Subcool- 13/4 Outdoor Entering Air Temp-96 Outdoor Fan FLA- .7 Compressor RLA/LRA- 14.6/*** Contactor Voltage- 244/25 Capacitor Rating- 22.37/4.79 Indoor Return Dry Bulb Temp- 75 Return Wet Bulb Temp- 59 Supply Temp- 57 Temperature Difference- 18 Required Difference- 16-20 Filter Sizes – (2)20x25x4 Changed Filters – Y (customer supplied) Blew out drain line: Y Returned tstat to original settings: Y Unit operational; prior to leaving: Y Notes- Unit was operational on arrival. Checked filters. Checked operating pressures and temperatures. Checked indoor and outdoor electrical. All other components showed no visible issues at this time. Recommend UV coil treatment-(to prevent organic growth, improve air quality, and maintain efficiency). Scheduled next tune up date: 01-20-21 12-4pm